Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Partial Discharge Pulse Calibrator
TPK
Partial discharge puls calibrator TPK is a battery-powered handheld device for determining the correction factor in a Partial Discharge test circuit and to verify the Partial Discharge measurement.
-
product
Gas Calibrators and Zero Air Generators
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
product
Acoustic Emission Calibrator
AE calibrator is similar to a simple signal generator, it can generate a variety of controlled waveform signal, different types, different amplitude and different frequency. It can help users calibrate acoustic emission detection equipment before acoustic emission detection.
-
product
Calibration Lead - Precision Resistor Modules
40-975-037-02-1m
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-293 and 50-293 enabling calibration via an external DMM.
-
product
Multiport Calibrated Measurements With Switch Instruments
S95553B
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments such as the M9164A/B or M9165A/B PXI Solid-state Switch Matrix. The software includes an easy-to-use measurement wizard that simplifies measurement procedures and reduces the setup time of complicated multiport measurements. The VNA displays measured multiport S-parameters.With the combination of M980xA PXIe VNAs and M916xA/B switch matrix, up to 66 ports (2 VNAs (4 ports and 6 ports M980xA), plus 4 modules of 2x16 M9164A/B) can be configured and supported. Measurement specification is supported when using the M9164B/M9165B 9 GHz switch modules.
-
product
Standard Slide Rail Size 3
65-051
Automatic release in extended position. The chassis/cabinet mounted slide rails are ultra rugged and hold significantly more weight and can withstand shock and vibration in harsh environments.
-
product
Voltage Calibrators
Practical Instrument Electronics, Inc.
PIE has a voltage calibrator to fit your needs from the PIE 235 voltage and pH simulator to the advanced troubleshooting capabilities of the PIE 532 milliamp and voltage calibrator. The PIE 532 includes our patented Loop Diagnostic Technology! All the voltage/milliamp calibrators have fuse-less protection, rugged design and long battery life. With the PIE 535, source 4 to 20 milliamps or 10 to 50 milliamps into loop instruments and drive final control elements such as valves and actuators with up to 42 volts.
-
product
Robotics and Machine Vision Standards
Accuracy in machine vision systems is critical to achieving strategic goals regarding quality, efficiency, and consistency. Use our ACCUplace product lines to calibrate vision systems’ distortion, placement/alignment, or other field parameters in systems used for guidance, identification, gauging, and inspection. Using our specialized ACCUedge® technology, our Robotic and Machine Vision Standards are manufactured with line-edge quality that is second to none in the industry, providing the precision needed to calibrate almost any system. Should you need to alter feature patterns, size, or substrate to fit your needs, fill out our Optical Components and Standards form to start the conversation.
-
product
Instrument Calibration Services
Instrument Calibration ServicesCalibration is a fundamental step in the process of measurement. It ensures that the instrument used for testing accurately indicates the required measurement parameter and that the instrument is performing to its specification.
-
product
VCOM Amplifiers And Calibrators
Renesas offers various VCOM amplifiers including rail-to-rail input-output operational amplifiers and rail-to-rail input-output buffers, as well as programmable VCOM calibrators that are ideal for display applications.
-
product
Temperature Calibration
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4S
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard DUO
Rotary Precision Instruments UK Ltd
Ultra precise rotary tables intended for fine inspection, metrology and test applications.2 axis design for rotary tilting applications with self-locking worm gearing and a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
product
Portable Gas Calibrator
Model T750
Teledyne Advanced Pollution Instrumentation
The Model T750 is a portable, microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750 is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.The Model T750 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPT. A number of calibration sequences may be programmed into the non-volatile memory of the Model T750, covering time periods up to a year.
-
product
Hydrogen Frequency & Time Standard
CH1-1007
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2SB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Disciplined Frequency Standards
2960AR and 2965AR
The 2960AR has a rubidium timebase and provides two 10MHz and one 5MHz sine wave outputs. The 2965AR has a rubidium timebase and provides one 10MHz, one 5MHz and one signal generator output. The signal generator output uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50MHz via an RS232 serial interface. Both models can be disciplined by a 1pps input signal and provide a 1pps output. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.
-
product
Suitable For RTD Sensors Approved To ATEX And IECEx Standards
TTR200X -
The TTR200X is our mid range transmitter for RTD or Slidewire sensors approved to ATEX and IECEx standards. It can accept many different types of RTD sensor such as Pt100, 500, 1000 etc and slidewire sensors up to 100K Ohm
-
product
2210A & 2211A Quartz Frequency Standards
Precise Time and Frequency, Inc.
The ptf 2210A Quartz Frequency Standard has been designed to provide a highly stable and spectrally pure frequency reference for applications requiring the ultimate in short term frequency performance.The instrument contains a double oven controlled stress compensated (SC cut) quartz crystal oscillator (OCXO) to give the ultimate in performance.Ideal for laboratory or system use, the unit provides good stability performance at lower cost and with improved phase noise.
-
product
Acoustic Calibrator
Beddrock BACx
The Bedrock BAC1 and BAC2 acoustic calibrators are used to accurately verify (and if neccesary adjust) the level calibration of your Bedrock acoustic measuring instruments. We recommend the BAC1 for the Bedrock SM90 class 1 instrument, and the BAC2 (which complies with class 2) for the Bedrock SM30 and SM90. Each calibrator comes with an individual calibration certificate.
-
product
Energy Meter Calibration
GF312D1
Beijing GFUVE Electronics Co.,Ltd.
The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.
-
product
Calibration Units
Optical Stroboscope and Tachometer European Calibrator Unit was originally designed for in-house test and calibration of our comprehensive range of Digital Optical Tachometers, Optical Speed sensing products and Stroboscopes.
-
product
Working Standard Shunts
CSW
CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.
-
product
ReCalibration and Post Calibration Software
SI58
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.
-
product
Cryogenic Millimeter-Wave / Microwave Test Fixtures and Calibration Kits
upj10
KEYCOM''s cryogenic millimeter-wave / microwave test fixtures and calibration kits are specifically optimized for testing the performance of patterns between the edges of printed boards(edge type) and circuit testing on the printed boards(probe type). They are also designed to minimize heat capacity by miniaturizing their dimensions so they cool off efficiently, and materials with low coefficient of linear thermal expansion such as invar are used for major parts where high dimensional stability is required. Their operating frequency ranges from DC to 110GHz.
-
product
WAVEPULSER-40IX + WAVEPULSER-SI-STUDIO-NRZ + Adaptors and Calibration Kit
WAVEPULSER-40iX-BUNDLE
High-speed Interconnect Analyzer, 4-port, S-par @40 GHz, <1 mm Res., 4 phase matched cables, bundle.
-
product
Standard Light Source
SLS-50W
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.