Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Conformance Calibration Standard Test Card for GS1-DataBar Symbol Verifiers
AI-CCS-DATABAR
This test card is ideal for testing verifiers, scanners, and other GS1-DataBar barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
product
Digital Load Calibrator
HS 2000
Jinan Testing Equipment IE Corporation
The load cell calibrator is used to calibrate the load of testing machine and hardness tester, and also can be used for force measuring. It is digital display type with high accuracy of less than +0.3%, and easy to operate
-
product
Calibration Light Sources
An adjustable mount for Sciencetech''s line of calibration pen lamps.Power supply and pen lamp are not included. See the calibration sources brochure for more information.
-
product
Automatic Calibration Module
ACM2509
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
product
Capacitance Standard Frame
AH 1100
The AH 1100 capacitance standard frame containing from one to four AH 11A fused-silica capacitance standards provides reference capacitors of unexcelled stability. The inherent stability of this system when subjected to mechanical or thermal shock makes it the ideal transfer standard for capacitance. The built-in precision temperature controllers make it a simple, reliable system to use.
-
product
Reference Standard
Beijing GFUVE Electronics Co.,Ltd.
It has been designed for universal laboratory and test applications and is intended for checking and the calibration of reference standards for electrical power and energy.
-
product
Frequency Standards
Precision Test manufacturers a complete range of frequency standards. This includes rubidium and OXCO models either free running or controlled by an external reference (GPS, GLONASS, Galileo, 1pps, 5 MHz, 10 MHz, IRIG-B etc). Output frequencies typically 1 MHz, 5 MHz, 10 MHz, 10.23 MHz, 13 MHz, 100 MHz or bespoke frequency.
-
product
Calibration Services
OMEGA offers a broad range of calibration services, with primary and secondary NIST traceable standards for calibrating temperature, infrared humidity, pressure, flow, and force products.
-
product
Standard High Speed D/A Converters
Analog Devices digital-to-analog converter (DAC) portfolio provides solutions for your high speed and precision DAC applications. Thanks to complete data sheets and evaluation boards, as well as broad support among our clock and timing, RF, power management, and op amp portfolios, our DACs can help you reduce time to market and system design costs. A high speed range from 30 MSPS to multi-GSPS, 8- to 16-bit resolution, and a tiny package are just some of the features that make our industry-leading d/a converters stand out.
-
product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations
-
product
Calibration And Measurement
Ectron has a long tradition dating back to 1964 in being the industry leader in supplying super high precision, highly reliable and accurate Metrology, Simulators/Calibrators products.
-
product
Multiple High Resistance Standard
MHS
*1 MEGOHM TO 1 TERAOHM*FULLY GUARDED*HIGH IMMUNITY FROM AMBIENT TEMPERATURE CHANGES*TRANSPORTABLEOhm-Labs' new Multiple High Resistance Standard maintains state-of-the-art resistance at levels above 1 megohm.
-
product
Thermometer Calibrators
Check-Set Series
Tel-Tru® Manufacturing Company
The Check-Set series is the perfect temperature reference device for plant quality assurance, process control, food safety, instrument calibration and service, and HACCP compliance (Hazard Analysis Critical Control Points). It is easy to use, reliable, accurate, and compatible with a wide range of dial and digital thermometers, filled system bulbs, and electronic temperature sensors.
-
product
Automatic Calibration Module
ACM2506
ACM2506 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 6.5 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
product
NIST Calibration for D400A-AT
D400A-AT-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Resistor Calibration Boxes
RCB-1
Standard Electric Works Co., Ltd
● The RCB-1 is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturing the RCB for special customers.
-
product
Data-based Modeling and Calibration
ASCMO
ETAS ASCMO is the easy-to-use-solution for advanced model-based calibration and data-based modeling in significantly less time. ETAS ASCMO enables the fast and efficient development of accurate data-based models. Once created, these high-accuracy models can be used to optimize parameters of real systems such as engine ECUs or plant models in different simulation environments (e.g. Simulink or HiL-Systems). Both, steady state and dynamic/transient system behaviors can be captured.
-
product
GFS Primary Gravimetric Flow Standard
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
product
Speed-O-Calibrator
16470
The Speed-O-Calibrator consists of two sections, control box and drive unit. The control box is stored inside the drive unit for easy portability. The control box weighs less than 6 lbs and is used in the cab of a locomotive to control the speed of the Axle Alternator Drive Unit. The Drive Unit drives the Axle Alternator at various speeds while the user verifies that the correct speed is displayed in the cab. The test system provides a complete test of the speedometer system, including all types and paddle lengths of Axle Alternators.
-
product
Gasmet Calibrator
Gasmet portable calibrator is one of the most important tools in generating new applications for the Gasmet FTIR gas analyzer. The calibrator incorporates a syringe pump, a manual needle valve, a mass flow meter, and a stainless-steel injection chamber. The syringe pump injects precise amounts of liquid or gas into a hot nitrogen gas flow, thus producing a continuous flow of a known concentration calibration gas.
-
product
Radiometry Calibration
Trescal provides full Radiometry Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Radiometry Calibration services can be delivered at your site or at our lab. Accreditations for our radiometry calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
Portable Calibrator
MC141
Voltage range from 0 to 750 V DC/AC with uncertainty 0.01% Current range from 0 to 2 A DC/AC with uncertainty 0.02 % Calibrated sinusoidal output signal DC - 1kHz. Set standard resistors from 10 Ohm to 100 MOhm in decade values with uncertainty 0.02 %. TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250 oC to 1850 oC
-
product
Color Calibration & Profiling
For both amateurs and professionals photographers, filmmakers, designers, premedia and printing operators achieving predictable results from capture to output can be a challenge. Color Perfectionists turn to X-Rite for affordable, professional, quality calibrating and profiling solutions that make sure all of your devices monitors, projectors, cameras, scanners, printers and mobile devices are speaking the same language.
-
product
Standard GaN Amplifiers
A GaN (Gallium Nitride) amplifier is a power amplifier that uses GaN, a wide-bandgap semiconductor material, to provide high power density, efficiency, and frequency capabilities.
-
product
Standard Current Transformers
Measurements International Ltd.
Single Range, Highest Permeability, Wide Measurement Range, Negligible Current Errors, High Accuracy.
-
product
Insulation Tester Calibrator
M191
High resistance calibrator for insulation testers up to 10 kV. Other insulation related functions include HV capacitance, short current, dielectric and polarization parameters and timer test.
-
product
Standard Resistor Oil Bath
9400
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
product
Field Strength Calibration Probe
Beijing KeHuan Century EMC Technology Co,.LTD
Three-axis omnidirectional 100kHz~6GHz light transmission.
-
product
Primary Standards
Primary standards (often also referred to as mechanical dead-weight testers, pressure balances or primary pressure standards) are the most accurate reference instruments for pressure. Their functional principle is based on the physical principle of pressure = force/area. Mass pieces placed on the top of a piston-cylinder system are the source of a precisely defined force. By producing a certain (counter) pressure inside the primary standard an equilibrium is achieved: the mass pieces, including the free-running piston of the piston-cylinder system, are floating, which will lead to a very accurate pressure at the test port which measured through piston gauge technology.