Product
XYZ Color Sensor
AS7261
-
Calibrated XYZ color sensor provides complete, integrated platform for handheld color analyzers, color calibration and mobile analysis devices. Tri-stimulus XYZ realized by silicon interference filters. UART or I²C slave digital Interface. 16-bit ADC with digital access. Programmable LED drivers. 20-pin LGA package 4.5mm x 4.7mm x 2.5mm, with built-in aperture. Compact true-color sensing. Applications; Color/CCT sensing, Fluid or reagent analysis, Color point comparison, Display calibration.
-
Product
Color Test Charts
-
Shenzhen ThreeNH Technology Co., Ltd.
3NH color test charts provide accurate color calibration and image consistency across devices. They are Ideal for cameras, printers, and scanners. These charts meet international standards, helping professionals achieve precise color reproduction in photography, printing, and display calibration workflows.
-
Product
Nonlinear Component Characterization 10 MHz - 110 GHz
S94510B
-
Measure and display the calibrated, vector corrected waveform of the incident, reflected, and transmitted waves of the DUT
-
Product
Counters and Timers
-
Orbit Controls counters and timers are designed for connection to practically all industrial sensors and pulse sources . They can be used as process monitors to display the process variable to be measured or as process controllers for control and monitoring tasks. The devices display and process pulses and frequencies, as well as quadrature signals from incremental and absolute encoded rotary encoders. In addition to information on the display, the devices also generate data and analog outputs and monitor preselected limit values. The process parameters are entered via the keyboard so that the display is calibrated in the required units and the output signals, serial interfaces and limit values are optimized.
-
Product
Handheld Water Quality Meters
LAQUA PC210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Online Conductivity Controller
LD-LOCC-A10
-
Online Conductivity ControllerLD-LOCC-A10features 3 points conductivity calibration system, TDS measurement mode, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, Temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. This controller measures Conductivity and TDS values in µS/ cm, and mS/ cm units.
-
Product
Online Dissolved Oxygen Controller
LD-LODC-A10
-
Online Dissolved Oxygen ControllerLD-LODC-A10features 1 to 2 points dissolved oxygen calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. It measures the amount of dissolved oxygen in mg/l, ppm units or in % of saturation. The accuracy of measurement is improved by manual salinity and barometric pressure compensation mode.
-
Product
Online pH Controller
LD-LOPC-A10
-
Online pH ControllerLD-LOPC-A10features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.
-
Product
Wavelength and Power Meter
WPM-1NM
-
•Wide range Wavelength Meter– Auto λ detection from 1270nm to 1610nm– Auto power calibration & display•FTTx/PON Wavelength Meter– 1310/1490/1550nm auto λ detection– Auto power calibration & display•Optical Power Measurement– Optical network power measurement– Power measurement for system & module•Insertion Loss Measurement– Optical network & component IL measurement– IL measurement for CWDM 16-wavelength•Smartphone Interface– Communicates with smartphone via bluetooth– Smartphone application software
-
Product
Display Color Analyzer
Model 7123
Analyzer
Luminance and chromaticity measurement of Color Display0.005 cd/m2low luminance measurement (A712301)Wide luminance range: 0.0001 to 25,000 cd/m2 (A712301) 0.01 to 200,000 cd/m2 (A712302)High accuracy measurementMaximum 9 display modes: xyY, TΔuvY, u’ v’ Y, RGB, XYZ, Contrast, ProgramAble to control Video Pattern Generator and UUT (Unit Under Test)Built-in contrast measurement function to calculate the contrast ratio directlyEquipped with programmable test items that can complete the planned tests with one single buttonSupport USB flash disk that can copy the test procedures to other station for useJudgment function embedded to judge the test result automatically with one single buttonCalibration period setting and reminding functionMemory for storing 100 channels of standard color data and calibration dataBuilt-in flat display calibration data LCD-D65 & LED-D65* to be applied for chromaticity measurement instantlyOptional display white balance alignment system can be used to integrate all optical test stations to one single station
-
Product
Handheld Water Quality Meters
LAQUA PC220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Measuring Management
-
Our test equipment is more than a test-set with a screen. Our application software provides an integrated tool to easily store the measurements at different stages and create a log of what we have done. Each measurement stores all data and settings, including display, markers and calibration.
-
Product
Calibration Short For Digital Multimeters
34172B
Calibration Short
The Keysight 34172B digital multimeter calibration short is a set of two shorts which provide a convenient and reliable method to apply a short to the input connectors of the multimeter. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals.
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
7-Meter Laser Head Cable
10882B
Calibration Cable
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
Electronic Calibration Module (ECal), 67 GHz, 1.85 Mm, 2-Port
N4694D
Electronic Calibration Module
The Keysight N4694D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4694D is a precision 2-port ECal module that supports 1.85 mm connectors up to 67 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4694D is included for securing your ECal module and accessories.
-
Product
15-meter (49 feet) Sensor Cable
E1739C
Calibration Cable
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
Mechanical Calibration Kit
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
Electronic Calibration Module
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
Electronic Calibration Module
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
Mechanical Calibration Kit
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
Product
Electronic Calibration Module (ECal), 26.5 GHz, 3.5 Mm, 2-port
N4691D
Electronic Calibration Module
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
Mechanical Calibration Kit
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
RF Electronic Calibration Module (ECal), DC To 13.5 GHz, 4-ports
N4431D
Electronic Calibration Module
The Keysight N4431D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4431D is a precision 4-ports ECal module that supports multiple selection of connectors like Type-N, 3.5 mm, 7-16 and 4.3-10 connectors and can be mixed up to 13.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
Electronic Calibration Module
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Linear Measurement Kit
55280B
Mechanical Calibration Kit
The Keysight 55280B Linear Measurement Kit is part of the 5530 Laser Calibration System and enables the system to measure linear displacement and velocity along a machine's travel path. The purpose of this measurement is to document capability and, when possible, improve positioning accuracy along an axis for any machine that requires positioning accuracy and velocity control.