Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
-
Product
Universal Data Acquisition System
(UDAS/USB2250)
-
The Universal Data Acquisition System(UDAS) Sensor Interface provides real world data acquisition for your PC via the USB port. 16 sensor inputs in any mix or combination are accepted by the UDAS. No external signal conditioning is required. The UDAS includes configuration and data acquisition software.
-
Product
Low Pressure Variable Reluctance Sensor
DP45
-
The Validyne DP45 Very Low Differential Pressure Transducer is designed for extremely low pressure measurement in the order of 1 inch water column. This instrument is used extensively in connection with flow measurements where dynamic response at low flow rates is required. Dynamic line pressure effects are minimized due to the combination of low internal volume, symmetrical construction, and small volumetric displacement inherent in the DP45 design.
-
Product
Wet-Wet Differential Pressure Sensor
DP303
-
The DP303 features "take-apart" construction enabling the user to easily disassemble the unit for cleaning or to change full scale range by exchanging the sensing diaphragm. As noted from the Pressure Range/Diaphragm Selection Chart on the reverse side of this Data Sheet, a family of interchangeable diaphragms are available to cover virtually any full scale pressure range from 0.08 psid full scale to 5,000 psid full scale-all rated for operation at 5,000 psig line pressure!
-
Product
Digital Display for the Transducers and Transmitters
PS57
-
The PS57 is a combination power supply and 4 1/2 digit LED display for the P55/P855 family of pressure transducers and transmitters. The PS57 accepts 110 VAC power and provides the required 24 Vdc excitation for the transducer. The transducer signal is received and displayed directly in engineering units with bright 0.56 high red LEDs. The user can re-scale the display and set the decimal point by configuring internal jumpers. The analog output of the transducer, 5 Vdc or 4-20 mA, is available on rear-panel terminals.
-
Product
Carrier Demodulator with LED Display
CD23/223
-
The CD23 and CD223 Digital Transducer Indicators are designed for use with variable reluctance and differential transformer transducers. The CD23 accepts input from a single transducer, and the CD223 accepts two switch-selectable inputs, with Zero and Span controls for each input. The indicators provide 5 Vrms, 5 kHz carrier excitation voltage to the transducer(s) and solid state circuitry to amplify, demodulate and filter the transducer output signals. A 3 1/2 digit front panel display is standard, with a 4 1/2 digit display optionally available.
-
Product
Data Acquisition PCI Card
UPC2100
-
The UPC2100 PCI Sensor Interface card provides real-world data acquisition and control for your PC. Up to 16 sensor inputs in any mix or combination are accepted by the UPC2100. No external signal conditioning is required. The UPC2100 includes configuration and data acquisition software and is compatible with C#, .NET, C++, Visual Basic, LabView.
-
Product
Variable Reluctance Pressure Sensor Capable of Range Changes
DP15
-
An easy-to-replace pressure-sensing diaphragm maximizes the system's functionality by making pressure measurements from 2.22" H2O to 3200 psi in one compact unit. Rugged and reliable, the DP15 pressure sensor provides superior accuracy for measuring low-pressure liquids and gasses, while it withstands the abuse of field and laboratory testing. The ability to change full scale ranges make the DP15 a very cost effective solution for applications that need different pressure ranges or university labs.
-
Product
Very Low Pressure Variable Reluctance Sensor
DP103
-
The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.
-
Product
HVAC Pressure Transmitter
DP850/851
-
The DP850/851 transmitters are designed for low pressure measurement in HVAC applications. The DP850 is available in full scale pressure ranges as low as 0.25 inH2O and the DP851 can be ranged to 0.025 inH2O full scale. Both models are available in 4-20 mA or 0 to +5 Vdc signal output options.
-
Product
Test and Measurement Grade Vacuum Pressure Transducer
P897V
-
The P897V is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover. The P897V is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor. Small vacuum pressures are accurately measured with full scale vacuum ranges as low as 2.22 InH2O.
-
Product
Pressure Sensor Kit for Changing Ranges
DP15TL
-
The wide range of diaphragms furnished eliminates expensive stocking of several transducers and offers the versatility of the differential type bi-directional transducer at a very low cost. The broad line pressure capability of this unit makes it useful in almost every laboratory application from flow to level measurement, vacuum to 3000 PSIG. The high output, when used with a carrier system such as the Model CD15 Sine Wave Carrier Demodulator or the CD12 Transducer Indicator, provides resolution equal to many secondary standard units.
-
Product
General Purpose Pressure Transducer and Transmitter
P55
-
The robust P55 pressure transducer provides cost-effective reliability for severe test environments. With extreme resistance to shock and vibration, the P55 pressure transducer delivers the same high-level performance expected from more delicate differential pressure transducers and pressure transmitters. With variable reluctance sensing technology, the P55 pressure transducer delivers fast dynamic response, high resistance to vibration and superior signal stability through ambient temperature change for a wide variety of low-pressure to high-pressure measurements. The P55 pressure transducer will accept both liquids and gases directly at the sensing diaphragm and there are no internal isolation fluids to slow the sensor response or cause excessive temperature drift errors.
-
Product
Variable Reluctance Absolute Pressure Sensor
AP10
-
The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.
-
Product
Variable Reluctance Pressure Sensor with All-Welded Construction
DP10
-
The DP10 Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full scale output of 30 mV per volt at 3kHz. The unit operates with carrier system including the Validyne CD15 since wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator.
-
Product
Single-Channel DC Powered Carrier Demodulator
CD16
-
The CD16 Miniature Carrier Demodulator is designed to deliver a 0 to 5 Vdc output from a variable reluctance transducer and operate from unregulated 9 to 55 Vdc power. A square wave excitation of 5 kHz is furnished to the transducer and the solid state integrated circuit amplifier and demodulator converts the transducer signal to an analog dc output. Zero and Span adjustments are made through access holes in the case.