Impedance
-
product
Vector Network Analyzers
The VIA Bravo is a handheld Vector Impedance Analyzer for measuring the impedance and resonant frequencies of circuits and antennas. The VIA Bravo has the capability of providing accurate measurements and sweep displays of impedance, reactance, resistance, phase angle, return loss and SWR. The VIA Bravo’s testing functionality, combined with its 100 kHz to 200 MHz frequency range, make it a versatile tool for many service applications including areas such as MRI, wireless telemetry, 2-way radio, aviation, and Radio Frequency Identification (RFID).
-
product
Transducer Simulator
Model TS-16
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch: 0 to 3 mv/v in 15 steps of .2 mv/v
-
product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
product
Impedance Standards and Calibrators
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
product
Impulse Hammers/Impedance Heads
Impulse hammer excite from the smallest of structures to various civil engineering structures. The Dytran model 5800SL is an ultra miniature IEPE impulse hammer used to excite structures or machinery with a definable impulse force in modal and structural analysis of very light structures and impulse testing of very low mass, high resonant frequency components.
-
product
Differential Probe
DP-60HS
*High Sensitivity Model: x 1, x 5, x 10 Attenuation*1 MΩ // 10PF Input Impedance*High Frequency Operation: x 1(30 MHZ), x 5(60 MHZ), x 10(60 MHz)*Especially For Low Voltage: x 1(7 Vp-p), x 5(35 Vp-p), x 10(70 Vp-p)
-
product
Audio Impedance Testers
2706 IM
Standard Electric Works Co., Ltd
True measurement of speaker systems actual impedance at 1kHz.. Three test ranges (20Ω / 200Ω / 2000Ω) allow testing of home theater and commercial sound systems. Measures transformer impedances. Battery operated. Low battery indication. Data hold function. Timer function for continuous hands free operation. The timer can last about 3-5 minutes when users press. TEST ON/OFF button.
-
product
IDM+
Multi-functional fault recorder including: -- Disturbance fault record (DFR)- Dynamic disturbance recording (DDR) - Phasor measurement unit (PMU C37-118)- Power Quality (PQ Class A)- Travelling wave fault location (TWS to +/-60m) - Impedance fault location- Protocols (61850, Modbus, DNP3) - Sequence of event recording (SOE)- GPS, IRIG and NTP time sync- iQ+ masterstation software.
-
product
Nodal Impedance Analyser
QT-Hi1
Qmax Test Technologies Pvt. Ltd.
QT-Hi1 is an innovative Nodal Impedance Analyzer, which uses the industry’s proven V-I trace techniques of learn and compare of nodal impedances which are represented as VI Curves. It uses innovative Auto Best Curve fit technique an intelligent software alogorithm which enables automatic selection of the best fit value of Voltage, Source Impedance and Frequency of the stimulus waveform. The compact size with re-chargeable battery makes it an ideal companion for on-field applications. The wide 8” touch screen graphical display makes this tool more valuable in test and repair industry at all times.
-
product
Differential Probe
DP-800HS
*1:1 High Sensitivity*100 Gain Design*x1, x10, x100 Attenuator*Bandwidth: DC-50MHz*Input Impedance 3MΩ // 2.5PF*Max. 800Vp-p Input or ±400V DC or AC 280V RMS*Output Impedance 50Ω
-
product
High Voltage Probe
HVP-40
*MAX. Voltage : DC : 40KV, AC : 28KV, (50/60Hz only) CAT II.*1000MΩ Input Impedance.*Accuracy **DC: ± 1% to 20KV. ± 2% to 40KV. **AC: -5% to -10% (50/60Hz)*Division Ration : 1000:1*CE, TUV GS, UL, CUL, IEC1010
-
product
COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)
CVCT-S20
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.
-
product
Calibration
RF Test Equipment
We calibrate following types of RF test equipment:EMF test systems (frequency selective)EMF test systems (broadband)Field strength transfer standards (e.g. RefRad)Line Impedance Stabilisation Network (LISN)Cable, attenuator, couplerAntennaField Probe
-
product
High Quality UCI - And Leeb-measuring Technology
SONODUR Product Family
Foerster Instruments, Incorporated
The non-destructive UCI test method (Ultrasonic Contact Impedance) as well as the Leeb test method enable fast and mobile measurement as a supplement to the classical hardness test. Due to the compact measuring probes and sensors of the SONO series, the devices can also be used in difficult test positions and with complex component geometries. Fields of application are e.g. incoming goods inspection, mix-up testing, production control, quality assurance, weld seam testing, cut edge testing, maintenance on installed components as well as the replacement of dynamic hardness testers for small material thicknesses (below 50 mm, e.g. boilers, tubes).
-
product
Performance Board For LSI Tester
Place inner layer GND plane all over. Impedance control of signal line and crosstalk prevention, etc. contribute to improvement of characteristics in various ways.
-
product
Decade Capacitance Box
1412-BC
The wide capacitance range and high resolution of the GenRad 1412-BC decade capacitance box make it exceptionally useful in both laboratory and test shop. Owing to its fine adjustment of capacitance, it is a convenient variable capacitor to use with an Impedance Comparator. The polystyrene dielectric used in the decade steps is necessary for applications requiring low dielectric absorption and constancy of both capacitance and dissipation factor with frequency.
-
product
Known impedance for use in loudspeaker measurements
Impedance Box
An impedance box is necessary for measuring the impedance of a loudspeaker. Listen Inc.’s impedance box contains a 0.25Ω resistance. This value is suitable for most loudspeakers, but may be easily swapped out for a different value by the user if speakers with a particularly high or low impedance are being tested. It is available with either XLR or 1/4″ balanced connectors. Please specify type of connectors when ordering.
-
product
Micro Coax, Contact, Receiver, RG316 Double Shield
610140104
Primary mating contact 610141104. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor – SolderShield – SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss -√f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Mini Coax, Contact, ITA, RG178
610103157
Mini Coax, Contact, ITA, RG178.Mechanical SpecificationsDurability 20,000 cyclesContact Material Center conductor – BeCuShield – BrassContact Plating Shield 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 milliohms @ 0.5 Amp & always < 10 milliohmsCable Specifications RG178Environmental SpecificationsOperating Temperature -50C to +105CInsulation Resistance 1000 MΩ min.
-
product
Differential Probe
DP-40K
*MAX. Input Voltage: ±20KV DC or 40KV p-p or AC 14KV rms*Bandwidth: DC-20MHz*Input Impedance 100MΩ// 1PF*x500, x5000 Attenuator*To Ground MAX. Voltage: 10KV CAT III*Output Impedance 50Ω
-
product
Loop/Line Impedance Testers
Shanghai Beha Electronics Co., Ltd.
*Built-in earth tester.*Built-in loop/psc tester. 0.03 - 2000Ω (software ctrl).*Built-in voltmeter.*Built-in wiring checker.*One push button smart control.
-
product
Micro Coax, Contact, ITA, 75 Ohm, RG179
610141103
Primary mating contact 610140103. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 75ΩFrequency Range DC – 2 GHzVSWR 1.39 @ 2 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG179Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Coax, Contact, Receiver, 75 Ohm, RG179
610104157
Primary mating contact 610103169. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Female & Male Shield – brassCenter Contact – BeCuContact Plating Center Conductor Shield – 30µ” Au over 100µ” NiContact Termination Center Conductor – Crimp or SolderShield – CrimpInsulator PTFEMating Force 4.0 lbs max [1.81 kg]Electrical SpecificationsCharacteristic Impedance 75 ΩFrequency Range DC to 3 GHzVSWR < 2.95 @ 3 GHzInsertion Loss -1.64 @ 3 GHzDWV 800 VRMSContact Resistance Center Contact - 5 mΩOuter Shield - 3 mΩCable Specifications RG179Environmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition AInsulation Resistance 1000 MΩ min.
-
product
High Impedance Differential Relay
High impedance protection schemes are widely used for the protection of BUS bars, generators, motors & power transformers. BUS bar protection schemes utilizing electromechanical high impedance differential relays are often used due to their simplicity, reliability & comparatively low cost.
-
product
Ground Pro Meter
Verifies Critical Grounding Parameters of a FacilityMeasures AC voltage, DC voltage, EMI voltage and AC impedanceProvides Accurate Measurements of Ground Impedance on a Working ToolMeets ANSI/ESD S20.20 requirements for AC impedanceIdentifies Potential EOS Generators
-
product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
product
Differential Probe
DP-35
*High Sensitivity, High Voltage Model .*35MHz/1600 Vp-p Max.*Input Impedance 8MΩ//2.5PF*x10, x100 Attenuator, Easy to Convert.*Separating Design(Standard No.114205) Convenient & Durable.
-
product
N1.2 Calibration Kit