Impedance
-
Product
RF Power Generators
-
MKS RF Power Generators provide reliable solid state power for thin films processing equipment. They are vital components of semiconductor fabrication systems, which produce the integrated circuits (ICs) or chips required by modern computers and electronic equipment. MKS RF Generators, combined with our Impedance Matching Network and our V/I Probe form a complete RF Delivery System.
-
Product
Adapter
P350NM75NF
-
P350NM75NF Adapter, Frequency Range: Up to 12 GHz, Impedance: 50 Ohm to 75 Ohm
-
Product
NM-SM 50 N-Male to SMA-Male Adapter
-
NM-SM 50 Adapter, N-Male to SMA-Male, Frequency Range: DC to 18 GHz, Impedance: 50 Ohm
-
Product
Battery Impedance Tester
-
TES Electrical Electronic Corp.
Test conditions without shutting down battery.Simultaneously measures battery resistance, Voltage, current, and temperature.Auto-hold and auto-data storage. Comparator Function.Rates conditions as pass, warning, or fail.
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
High Quality UCI - And Leeb-measuring Technology
SONODUR Product Family
-
Foerster Instruments, Incorporated
The non-destructive UCI test method (Ultrasonic Contact Impedance) as well as the Leeb test method enable fast and mobile measurement as a supplement to the classical hardness test. Due to the compact measuring probes and sensors of the SONO series, the devices can also be used in difficult test positions and with complex component geometries. Fields of application are e.g. incoming goods inspection, mix-up testing, production control, quality assurance, weld seam testing, cut edge testing, maintenance on installed components as well as the replacement of dynamic hardness testers for small material thicknesses (below 50 mm, e.g. boilers, tubes).
-
Product
Signal Integrity Test Products
RoBAT RCI
-
*TDR & TDT, Measurement Capabilities*Impedance, Skew, Backdrill measurements*Automated Optical Inspection*DC Electrical Test*Now available with 4 heads*24 port (1 port per channel) TDR/TDT unit*Future capabilities – Fully automated VNA test (4 port S-Parameter Measurement)
-
Product
Potentiostat/Galvinostat Electrochemical Instuments
-
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
Product
Differential Probe
DP-02VF
-
*150MHz High Frequency*MAX. Input Voltage:*±40V DC or 80V p-p or AC 28V rms*Bandwidth: DC-150MHz*Input Impedance 1MΩ // 7.5PF*X2, X20 Attenuator*To Ground MAX. Voltage: 40V*Output Impedance 50Ω
-
Product
Impedance Analyzer 1MHz-20Hz
IA1000
-
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
Product
8-Ch Analog Input Module With Independent Input Range
ADAM-5017P
-
Accuracy: Voltage mode : ±0.1% or better, Current mode : ±0.2% or betterHigh Common Mode: 200 VDCOver Voltage Protection: ±60 VDCBuilt-in TVS/ESD ProtectionIsolation Voltage: 3,000 VDCCMR @ 50/60 Hz: 92 dB min.Channels: 8 differential and independent configuration channelsInput Impedance: Voltage: 800kΩ, Current: 120Ω (Build-in 120Ω. register for Current Input) for Currenlnput Type: mV, V (supports uni-polar and bipolar), mASampling Rate: 10 samples/sec
-
Product
Medical Leakage Current Tester
2675Y
-
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.
-
Product
Electrical Tester For Voltage
PDT35
-
Automatically Selects VAC, VDC, or Continuity TestComplies with EN 61010-1 For Use in CATIII 600 V Environments1999 Count LCD DisplayAuto Power On/OffHigh Input Impedance -- 400 kVoltage AC: Max Range 600 V, Accuracy +/- 1.5%Voltage DC: Max Range 600 V, Accuracy +/- 3.0%Continuity TestAccessories Included: Test Leads, 2 'AA' BatteriesDimensions: 8.46' H x 2.83' W x 1.44' DWeight: 8.29 oz.Sold as : Unit
-
Product
Professional Cordless Circuit Tester
CT8002
-
No Ground or clip required. No ground wire means no wire tangles nor time lost searching for grounding points. High Impedance Electronic circuitry. Safety V-groove needle accessory for piercing and carrying. Negligible current draw ( 20 micro-amps) is 10,000 times less than regular lamp type testers. This gives complete safety when working around sensitive electronic control modules and sensors. Operating range between 3 and 28 Volt DC in battery powered systems.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Potentiostat Galvanostat
1287A
-
The Solartron Analytical 1287A potentiostat and galvanostat is a high accuracy, wide bandwidth instrument which offers a range of DC test capabilities. The 1287A can be coupled with a frequency response analyzer, such as the Solartron Analytical 1260A or 1255B, and ZPLOT software for AC tests such as Electrochemical Impedance Spectroscopy.
-
Product
RF Adapters
MHV Adapters
-
MHV Jack to MHV Jack Adapter Non-Constant Impedance Straight 4-Hole Flange.
-
Product
NF50 N-Female to N-Female Adapter
-
NF50 Adapter, N-Female to N-Female, Frequency Range: up to 6 GHz, Impedance: 50 Ohm
-
Product
Transducer Simulator
Model TS-16
-
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch: 0 to 3 mv/v in 15 steps of .2 mv/v
-
Product
Vector Network Analyzer
Bode 100
-
With the multifunctional Bode 100 you get an exact picture of your electronic circuits and components in a frequency range from 1 Hz to 40 MHz. The Bode 100 is not only a state of the art Vector Network Analyzer, it also works as: Frequency Response Analyzer, Impedance Meter, Gain Phase Meter, Sine Wave Generator.
-
Product
5uH Line Impedance Stabilisation Network LISN - CISPR 25
TBOH01
-
The TBOH01 5H LISN is a device required to setup conducted noise measurements of DC-powered devices. It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.
-
Product
Differential Probe
DP-8V
-
*MAX. Input Voltage: ±4KV DC or 8KV p-p or AC 2.8KV rms*Bandwidth: DC-50MHz*Input Impedance 20MΩ// 2PF*x10, x100, x1000 Attenuator*To Ground MAX. Voltage: 4KV CAT III*Output Impedance 50Ω
-
Product
Calibration Kit
N912
-
*N912 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Differential Probe
DP-16VF
-
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X400, X4000 Attenuator*To Ground MAX. Voltage: 3.5KV CAT III*Output Impedance 50Ω
-
Product
Impedance Matching Pads
-
Impedance matching pads from BroadWave eliminate impedance discontinuity (mismatches) without introducing reflection to the circuit. Custom units are available in a variety of impedance and connector types from DC to 4 GHz. BroadWave Technologies impedance matching pads preserve signal integrity by matching virtually any transmission line.
-
Product
Calibration Kit
N612
-
*N612 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Battery Impedance Tester
-
Weshine Electric Manufacturing Co., Ltd
The DC test method is adopted to simulate the actual use of the battery in a real and objective way, which can effectively eliminate the hidden dangers such as deficiency, deficiency and connection failure between batteries while measuring the internal resistance of the battery.
-
Product
High Voltage Probe
HVP-40DM
-
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
Product
High Voltage Probe
HVP-40
-
*MAX. Voltage : DC : 40KV, AC : 28KV, (50/60Hz only) CAT II.*1000MΩ Input Impedance.*Accuracy **DC: ± 1% to 20KV. ± 2% to 40KV. **AC: -5% to -10% (50/60Hz)*Division Ration : 1000:1*CE, TUV GS, UL, CUL, IEC1010





























