Impedance
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
NM-SF 50 N-Male to SMA-Female Adapter
NM-SF 50 Adapter, N-Male to SMA-Female, Frequency Range: DC to 18 GHz, Impedance: 50 Ohm
-
product
Potentiostat Galvanostat
1287A
The Solartron Analytical 1287A potentiostat and galvanostat is a high accuracy, wide bandwidth instrument which offers a range of DC test capabilities. The 1287A can be coupled with a frequency response analyzer, such as the Solartron Analytical 1260A or 1255B, and ZPLOT software for AC tests such as Electrochemical Impedance Spectroscopy.
-
product
Differential Probe
DP-16V
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-50MHz*Input Impedance 30MΩ// 1.5PF*x20, x200, x2000 Attenuator*To Ground MAX. Voltage: 8KV CAT III*Output Impedance 50Ω
-
product
High Impedance Transformers
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
product
Professional Cordless Circuit Tester
CT8002
No Ground or clip required. No ground wire means no wire tangles nor time lost searching for grounding points. High Impedance Electronic circuitry. Safety V-groove needle accessory for piercing and carrying. Negligible current draw ( 20 micro-amps) is 10,000 times less than regular lamp type testers. This gives complete safety when working around sensitive electronic control modules and sensors. Operating range between 3 and 28 Volt DC in battery powered systems.
-
product
Micro Coax, Contact, ITA, RG316
610141101
Primary mating contact 610140101. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Potentiostat/Galvinostat Electrochemical Instuments
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
product
Transmission Measuring Set
Model 2031 / 2031A
- Compact Two in One Instrument with Level Oscillator & Level Meter- Selectable Spot Frequencies upto 4KHz- Digital dB Meter to Measure Level from-60dBm to +20dBm- Under / Over Range Indication- Built-in Rechargeable Battery- Lo-Batt Indication- Easy to Operate, Light in Weight & Portable- Selectable Spot Frequencies from 200Hz to 4000Hz- Extra Switchable Input & Output Impedance of 1120 ohms)
-
product
Calibration Kit
N912
*N912 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
product
Impedance Analyzer
6632
Frequency range: DC, 10Hz to 1/3/5/10/20/30MHz/50MHz. Basic accuracy up to ±0.08%. Automatic Level Control (ALC). Output impedance 25Ω/100Ω, switchable. Equivalent Circuit Analysis . Built-in DC Bias voltage ±12V. Ultra-high measuring speed < 3ms. Built-in the Dielectric constant-εr. Built-in the Permeability-μr. Support PC Link Software.
-
product
Differential Probe
DP-08VF
*MAX. Input Voltage: ±400V DC or 800V p-p or AC 280V rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X20, X200 Attenuator*To Ground MAX. Voltage: 400V*Output Impedance 50Ω
-
product
Coax, Contact, ITA, 75 Ohm HD, sm59/U Belden 1855A, 3 GHz
610102132
Primary mating contact 610102133. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter contact – BeCuContact Plating Center conductor shield –30µ” Au over 100µ” NiContact Termination Center conductor - SolderShield - CrimpInsulator PTFEMating Force 2.0 lbs max [0.91 kg]Electrical SpecificationsCharacteristic Impedance 75 ΩFrequency Range DC to 3 GHzVSWR ≤ 2.26 @ 3 GHzInsertion Loss -0.86 dB MaxDWV 800 VDC min.Contact Resistance 5 mΩ center/ 3 mΩ outer Cable Specifications sm59/U Belden 1855AEnvironmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition AInsulation Resistance 1000 MΩ min.
-
product
Cable Fault Locator
TX2002
Lowest Cost Full Specification Professional Graphical TDR Rugged Palm Top Design 350g (12oz) 5 Measurement Ranges up to 3500m (11,500ft) 50, 75 & 100 ohm Selectable Cable Impedance Built in Tone Generator for Pair Tracing & Identification Suitable for testing all Communications Cables Water & Dust Proof to IP54 Complete with tool-belt holster & test leads
-
product
Coax, Contact, ITA, 20/26 GHz, Flex 402
610102118
This contact available as a patchcord only. Please select link below to configure a patchcord.Primary mating contact 610102119. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield-SolderInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.25 for 2 - 18 GHz1.30 for 18 - 26 GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications Flex 402 (Only Available in Patchcords)Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MΩ Min.
-
product
Controlled Impedance Analyzers
HYPERLABS Controlled Impedance Analyzers can be used with various probes and adapters to quickly and reliably characterize impedance on PCB test coupons. These Test Systems are designed to comply with IPC-2141A standards for PCB coupon testing, and can be customized to meet specific customer needs.
-
product
8 GHz Impedance Matching Pad
This impedance matching pad is a lab grade tool used in RF and microwave matching to adapt 50 Ohm impedance to 75 Ohm impedance. It is used in measurement setups that require impedance conversion with low VSWR. The 8AP50NM75NF Impedance Matching Pad is a 50 Ohm – 75 Ohm or 75 Ohm – 50 Ohm impedance converter with type-N connectors.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Mini Coax, Contact, ITA, 22 AWG
610103172
Primary mating contact 610104160. (May mate with other Receiver contacts, as well.)Specifications Characteristic Impedance 50 OhmsFrequency Range DC to 1 GHzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzVSWR ≤ 1.06 @ 1 GhzOperating Voltage & Current 0.5 Amps Max. ContinuousDielectric Withstanding Voltage (DWV) 1500 VDC Min.Insulation Resistance 1000 MOhms Min.Contact Body Female & Male (RCV & ITA) – shield – brass, center conductor – BeCuContact Plating Center conductor – 60µ" Au over 100µ" Ni; Shield – 50µ" Au over 100µ" NiContact Termination Center Conductor – CrimpShield – Not ConnectedCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force 1.02
-
product
Time Domain Reflectometer
STEP TDRS
Cable Measurements: Distance, Fault Types, Distance to Faults, Impedance Readings, and Loop Resistance.
-
product
Signal Integrity Studio, Analysis & Simulation SW for WAVEPULSER High-Speed Interconnect Analyzer
WavePulser-Signal Integrity (SI) Studio
WavePulser Signal Integrity (SI) Studio is included as a single license in the WavePulser 40iX-BUNDLE or can be purchased as an additional license for offline access to additional users. WavePulser Signal Integrity (SI) Studio combines S-parameter, Impedance profiling and de-embedding measurements, channel and equalizer modeling, eye diagrams and jitter analysis in a single affordable software package for emulating the complete serial data channel.
-
product
Micro Coax, Contact, ITA, RG316 Double Shield
610141104
Primary mating contact 610140104. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
High Impedance Active Probes
7
Designed as a companion probe to Models 12C and 18C for driving integrated circuit lines so the Model 12C and 18C can be used to measure the response of adjacent nodes. The Model 7 consists of a flexible 6 foot, 50 ohm coaxial cable accurately terminated to 50 ohms in order to avoid undesirable reflections. A special miniature connector receives replacement coaxial probe tips that provide a shielded environment to within 3 mm of the fine tungsten probe point, thus minimizing capacitive coupling to other parts of the circuit. The replaceable coaxial probe tips are offered in various point sizes and can also be bent to any shape in order to accommodate a variety of probing geometries.
-
product
Micro Coax, Contact, ITA, 50 GHz
610141108
Primary mating contact 610140108. (May mate with other Receiver contacts, as well.) *This contact sold as a patchcord only.Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 30µ" Au over 100µ" NiContact Termination Solder Nut ClampInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC-50GHzVSWR 1.06+0.004 f(GHz)Insertion Loss - .095 x √f(GHz) dBDWV 700 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications Flex 405Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Mini Coax, Contact, Receiver, Solder Sleeve, RG316 & RG178
610104142
Mini Coax, Contact, Receiver, Solder Sleeve, RG316 & RG178.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Solder SleeveInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 2 GHzVSWR ≤ 1.2 @ 2 GhzInsertion Loss ≤ 0.05 dB @ 500 Mhz≥ -0.3 dB @ 2 GhzDWV 1500 VDC Min.Contact Resistance ≤ 5 mΩCable Specifications RG316 & RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Impedance meters
Electronic components meters for circuit verification in laboratories, technical schools and technical support centres.
-
product
Impedance Stabilization Networks
ISN
They are required for the measurement of conducted common mode noise on Telecom Cables of Information Technology Equipment (ITE). These measurements are necessary to meet the requirements specified in CISPR 22 and CISPR 32 standards.
-
product
Overhead Line & Cable Impedance Test Sets
T&R Test Equipment Overhead Line & Cable Impedance Test Sets
-
product
Materials Test Systems
An impedance analyzer is a device that uses a programmable AC voltage / current source, together with voltage and current measurement circuits, to characterize sample impedance over a wide range of frequency. An example of this being the world famous Solartron Analytical 1260A Impedance Analyzer that provides EIS impedance characterization over more than 12 decades of frequency from uHz to tens of MHz. Impedance Analysis characterization is a key technology that enables new materials development for semiconductors, smart-materials, ferroelectrics, piezo-electrics, solid oxide, solid electrolytes, ceramics, polymers, OLED and many more materials.





























