Impedance
-
product
Special Purpose Instruments
The Mechanical Impedance Sensor simultaneously measures an applied, driving-point force and response acceleration of a test structure for determining parameters such as mechanical mobility and mechanical impedance. The unit consists of a precision, shear mode accelerometer and a quartz force sensor in a common housing. Installation is primarily facilitated at the structural excitation points, in series with a stinger and vibration shaker.
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
PCIe-Mini
PCIe-Mini-AD8200
8 Channels 16-bit A/D converter Simultaneously Sampled• Fast throughput rate: 200 KSPS for all 8 channels• 8 Channels SE or 4 PSEUDO Differentials• Single-ended or 4 differential channels• True bipolar analog input ranges: ±10 V, ±5 V, selection applies to all Channels• Analog Input Clamp Protection• 1MΩ Analog Input Impedance• Programmable 2nd Order Anti-alias Analog Filter• Over-sampling capability with digital filter• 8Kx16 SRAM• PCIexpress compliant
-
product
RF Adapters
MHV Adapters
MHV Jack to MHV Jack Adapter Non-Constant Impedance Straight 4-Hole Flange.
-
product
The Leading Measurement System for the Analysis of Porous Materials
ELWIS
ELWIS (Evaluation of Light Weight Impedance System) offers a full and rapid characterization of porous materials based on the analysis of a single sample. The ELWIS system consists of the ELWIS-A and ELWIS-S components which can be used independently from each other although both applications are needed for a complete material simulation.ELWIS-A measures acoustic parameters that are needed to evaluate the acoustic performance of sound insulation and sound-absorbing multi-layer materials. An additional impedance tube for absorption measurements at higher frequencies is available for ELWIS-A.ELWIS-S measures structural parameters that are needed to simulate the dynamic and acoustic behavior of sound packages in the medium to low frequency range (including the "Poisson Ratio" for foam materials).ELWIS is very easy to operate: Thanks to its user-friendly software, the system can also be used to obtain reliable results by users with only limited experience in the characterization of porous materials.
-
product
CellTest Multichannel Potentiostat
Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.
-
product
Impedance Analyzers
HTF-1100.
A laboratory furnace used specifically for the electrical characterization of materials and also for heat treatment between ambient temperature and 1100 °C.
-
product
Coax, Contact, ITA, 20/26 GHz, 3.5MM, w/ SMA Adapter, 90 Series Modules only
610102134
Coax, Contact, ITA, 20/26 GHz, 3.5MM, with SMA Adapter (90 Series modules only)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination 3.5mm compatibleInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications 3.5mm compatibleEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MΩ min.
-
product
Mini Coax, Contact, ITA, RG316
610103115
Primary mating contact 610104114. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 mΩ @ 0.5 Amp & always < 10 mΩCable Specifications RG316Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Broadband Dielectric Spectroscopy
Material Sensing & Instrumentation
Broadband Dielectric Spectroscopy is a powerful tool for investigating a variety of dielectric processes for both electrical and non-electrical applications. Also called Impedance Spectroscopy, the measurement separates molecular process on the basis of response time, providing a unique relaxation frequency along with a signature variation with frequency.
-
product
Cable Fault Locator
TX2003
6 km (19,000ft) 0.5mtr dead Zone Selectable Cable Impedance Warble Tone Generator Rapid Fault Location Large 128x64 LCD with Backlight Scratch Resistant Display Environmental Protection IP54 CE Approved 3yrs Manufacturers Warranty 60 Hours Battery Life
-
product
Coax, Contact, ITA, 20/26 GHz, SF142B, 90 Series modules only
610102110
Primary mating contact 610102109. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield – Crimp/ClampInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHz w/ SF142 (20 GHz)Insertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications SF142B Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Differential Probe
DP-8V
*MAX. Input Voltage: ±4KV DC or 8KV p-p or AC 2.8KV rms*Bandwidth: DC-50MHz*Input Impedance 20MΩ// 2PF*x10, x100, x1000 Attenuator*To Ground MAX. Voltage: 4KV CAT III*Output Impedance 50Ω
-
product
RF Power Generators
MKS RF Power Generators provide reliable solid state power for thin films processing equipment. They are vital components of semiconductor fabrication systems, which produce the integrated circuits (ICs) or chips required by modern computers and electronic equipment. MKS RF Generators, combined with our Impedance Matching Network and our V/I Probe form a complete RF Delivery System.
-
product
Voltage Probes
In addition to EMI measurement with LISNs (Line Impedance Stabilisation Networks, Artificial Mains Networks), Probes are used for Terminal or Line voltage measurement.
-
product
Calibration Kit
N611
*N611 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm. * Connector Type: N-type.
-
product
Cable Fault Locator
TX2001
Lowest Cost Full Specification Professional Graphical TDR Rugged Palm Top Design 350g (12oz) 5 Measurement Ranges up to 3000m (10,000ft) 50, 75 & 100 ohm Selectable Impedance Built in Tone Generator for Pair Tracing & Identification Suitable for testing all Communications Cables Water & Dust Proof to IP54 Complete with tool-belt holster & test leads
-
product
Battery Impedance Tester
KVBT-15S
KV Hipot Power Test Equipment Co.,Ltd
Battery Internal Resistance Tester with advanced AC discharge measurement method, is applied to test accurately the voltage and resistance of battery capacity and state.
-
product
High Voltage Probe
HVP-39pro
* 39KVDC+ACpeak* 900MΩ Impedance* DC~50MHz(-3dB)* 1000:1 for Oscilloscope* Very Low Nosie
-
product
Transducer Simulator
Model 7
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch. 0 to 3 mv/v in 6 steps of .5 mv/v .
-
product
Calibration Kit
F7511
F7511 Calibration Kit, Frequency Range: up to 3 GHz, Impedance: 75 Ohm, Connector type: F-type
-
product
Line-impedance stabilisation network
NNB 21 set
The NNB 21 line impedance stabilization network is designed for measuring of grid bound interferences of a device under test according to the satndard CISPR 25/ISO 7637. It measures the RF interference, which couples into the vehicle electrical system. Measurements during the development in a frequency range from 100 kHz to 1GHz can be carried out.
-
product
Impedance Matching Pads
Surface mount and coaxial 50 Ohm / 75 Ohm impedance matching pads for CATV systems, broadband networks, test setups and more!
-
product
HIGH FREQUENCY DC BIAS
6565 SERIES
The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.
-
product
NF-SM 50 N-Female to SMA-Male Adapter
NF-SM 50 Adapter, N-Female to SMA-Male, Frequency Range: DC to 18 GHz, Impedance: 50 Ohm
-
product
Micro Coax, Contact, Receiver, RG316
610140101
Primary mating contact 610141101. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outerCable Specifications RG316Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
WavePulser 40iX High-speed Interconnect Analyzer
WavePulser 40iX Series
WavePulser 40iX is the ideal single measurement tool for high-speed hardware designers and test engineers. The combination of S-parameters (frequency domain) and Impedance Profiles (time domain) in a single acquisition with a deep toolbox provides unmatched characterization insight of high-speed interconnects.