Product
PXIe-8510, 6-Port PXI Vehicle Multiprotocol Interface Module
784122-01
Interface
2- or 6-Port PXI Vehicle Multiprotocol Interface Module—The PXIe‑8510 is a hardware-selectable controller area network (CAN) and/or local interconnect network (LIN) interface for developing applications with the NI‑XNET driver. The PXIe-8510 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device-driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex models and applications.
-
Product
DeviceNet I/O Expansion Racks
-
CANopen is a kind of network protocol based on CAN bus and has been used in various applications, such as vehicles, industrial machines, building automation, medical devices, maritime applications, restaurant appliances, laboratory equipment & research. It allows for not only broadcasting but also peer to peer data exchange between every CANopen node. DeviceNet based on the CAN bus is one of the world's leading device-level networks for industrial automation. It offers robust, efficient data handling and data acquisition because it is based on Producer/Consumer technology.
-
Product
5G Router
ICR-4434
Router
ICR-4400, GLOBAL, 5x Ethernet, 1x RS232, 1x RS485, CAN, SFP, USB, SD, Without Accessories. LTE Advanced Cat.12 Global Cellular Connectivity. Download Speed Up to 600 Mbps. Quad-core CPU with 1 GB RAM.
-
Product
CANdo Module
Auto
-
The CANdo AUTO Module is a rugged, multi-purpose CAN bus module with a USB port, two precision analogue inputs & a DC power supply input. The module is capable of operating either connected to a PC, or in a standalone mode powered from a 12 or 24V DC supply, such as a vehicle battery.
-
Product
NI-9860, 2-Port, C Series Vehicle Multiprotocol Interface Module
783703-03
Interface Module
2-Port, C Series Vehicle Multiprotocol Interface Module - The NI‑9860 is a hardware-selectable HS/FD controller area network (CAN) and/or local interconnect network (LIN) interface for developing CAN and/or LIN applications. As part of the NI‑XNET platform, the NI‑9860 works well for applications requiring high-speed manipulation of hundreds of frames and signals while taking other data acquisition measurements in the same CompactDAQ hardware platform or while performing low-level FPGA control and embedded monitoring in the same CompactRIO chassis.
-
Product
Ethernet Adapter Supporting up to Twenty ARINC-429 Channels in Any Combination
ES-9810/A0 (RUNET II)
-
The EXC-9810/Ax is an Ethernet adapter supporting up to twenty ARINC-429 channels in any combination of transmit and/or receive. All of the channels feature error injection and detection.adapter. Its small size and ability to interface through Ethernet interfaces make it a complete solution for developing, testing and performing system simulation of the ARINC-429 bus, both in the lab and in the field.The receive channels allow for the storage of all selected labels with status and time tag information appended to each word, and also allow for filtering and multi-storage modes of data words. The transmit channels operate via a transmit ‘instruction stack’ which allows scheduling of data transmissions and reduces the need for host computer intervention. The EXC-9810 supports up to four independent 8000 family avionics communication modules, allowing multiple different protocols to be mixed and matched on a single card. Modules available include MIL-STD-1553, MIL-STD-1760, MMSI, ARINC-429, ARINC-708, ARINC-717, Serial, Discrete and CAN bus. In addition, multiple units can operate on the same network, by programming each one with a unique IP address, and can be accessed from any computer on the network.The EXC-9810/Ax adapter is supplied with C drivers, including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application (only versions 8.1 or higher). Please see multi protocol 8000 modules for additional information on protocols that can be added to this card.
-
Product
InfiniiVision Oscilloscopes
3000A X-Series
-
100 MHz to 1 GHz, DSO and MSO modelsView time-correlated digital content with16 digital channels (MSO)Modulate signals within the scope with WaveGen, built-in 20 MHz function generator (optional)Quickly characterize signals with the built-in 3-digit voltmeter and 5-digit counter option Decode serial busses faster with hardware-based serial analysis options for CAN, LIN, IC, SPI, RS232 and more Protect your investment with full upgradability
-
Product
Valve Body Test Stands
-
SuperFlow’s line of valve body test stands offer transmission remanufacturers unmatched features like the WinDyn CAN Control mechatronic test option and fully automated testing to eliminate operator induced errors. The Axiline VBT-8000 accomodates more transmission applications than the next closest competitors combined and cover the range of light, medium, heavy and extreme duty transmissions like the X-1100. Plus, in the rare event you have an application that we don’t, we’ll develop it at your request. Don’t chance your quality reputation with whoever remanufactures your valve bodies, put Axiline test stands in your shop and take control of your quality and bottom line.
-
Product
NI-9881, 1-Port C Series CANopen Interface Module
781673-01
Interface Module
The NI‑9881 is a high-speed CANopen interface for developing CANopen applications in LabVIEW software on CompactRIO hardware. CANopen is the application layer that sits on top of the CAN physical layer often used for industrial automation … applications. It was designed for motion-oriented machine control networks, such as handling systems, but now it is used in a variety of applications, including medical equipment, off-road vehicles, maritime electronics, public transportation, and building automation. The NI‑9881 can transmit/receive process data objects (PDOs) and service data objects (SDOs) according to CiA‑DS 301. The NI‑9881 is compatible with only CompactRIO systems.
-
Product
sbRIO-9881, Non-Enclosed, 1-Port C Series CANopen Interface Module
785966-01
Interface Module
The sbRIO‑9881 is a high-speed CANopen interface for developing CANopen applications in LabVIEW software on CompactRIO hardware. CANopen is the application layer that sits on top of the CAN physical layer often used for industrial automation applications. The sbRIO‑9881 can transmit/receive process data objects (PDOs) and service data objects (SDOs) according to CiA‑DS 301. The sbRIO‑9881 is compatible with only CompactRIO systems. Non-enclosed modules are designed for OEM applications.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
Fault Insertion Unit
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
PXI CAN Interface Module
CAN Interface
PXI CAN Interface Modules communicate using onboard transceivers for High-Speed/Flexible Data‑Rate, Low-Speed/Fault Tolerant, and/or Single Wire CAN as well as any external transceiver. Using the NI-XNET driver, you can create applications that require real-time, high-speed manipulation of hundreds of CAN frames and signals. You can also import, edit, and use signals from FIBEX and DBC files in integrated CAN databases. The NI-XNET device-driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time.
-
Product
Easy-to-use Configuration And Data Handling Software For ReXgen
ReXdesk
-
ReXdesk is our freely distributable software configuration and general-purpose software tool to work with ReXgen. It is designed to make CAN bus data logging easy.
-
Product
UniCAN 3 Data Logger
-
With up to 12 CAN bus interfaces, freely configurable digital inputs and outputs, Wake-on-CAN, LAN, WLAN - When developing the UniCAN 3 data logger, numerous requirements from state-of-the-art vehicle development were taken into account.
-
Product
BCI Tester
-
Test scenario creation function of BCI test.・Test scenario auto-run feature.・Test results file generated automatically. (CSV file: can be customized)・CAN / LIN communication function, data logging. (FlexRey available)・Power I/O, ECU I/O control functions, data logging.・Anomaly detection function display.・Noise detection function.
-
Product
CAN Controller
MS 1529
-
- The "CAN" Bus Interface for Hall Controllers and Car controller- On-board EEPROM and KEY inputs for user settings parameters- LCD Module Interface- Eight 110 VDC Opto input interface- Six inputs interface (TINS, TUIB, TDIB, FIRE, FP, PRO-SW)- RS485 Interface and RS232 Interface (Optional)- Real time clock for Time Information
-
Product
PCI-8511, 1‑Port, Low‑Speed/Fault-Tolerant CAN Interface Device
780682-01
CAN Interface
1‑ or 2-Port, Low‑Speed/Fault-Tolerant CAN Interface Device—The PCI‑8511 is a fault-tolerant controller area network (CAN) interface for developing applications with the NI‑XNET driver. The PCI‑8511 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex models and applications.
-
Product
NI-9881, 1-Port C Series CANopen Interface Module
781673-02
Interface Module
The NI‑9881 is a high-speed CANopen interface for developing CANopen applications in LabVIEW software on CompactRIO hardware. CANopen is the application layer that sits on top of the CAN physical layer often used for industrial automation … applications. It was designed for motion-oriented machine control networks, such as handling systems, but now it is used in a variety of applications, including medical equipment, off-road vehicles, maritime electronics, public transportation, and building automation. The NI‑9881 can transmit/receive process data objects (PDOs) and service data objects (SDOs) according to CiA‑DS 301. The NI‑9881 is compatible with only CompactRIO systems.
-
Product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Qseven V2.0 SoM With IMX6 Quad/DualLite 800 MHz (Industrial) SoC, 1GB RAM, 4GB EMMC, GbE LAN, Audio And CAN
Q7M120
-
*Qseven v2.0 (70 x 70 mm)*Ultra low power consumption Cortex™-A9*2 CAN*24-bit TTL signal*LVDS/HDMI 1080P*10/100/1000 Mbps Ethernet*Linux 3.0.35/Android 4.3*Audio
-
Product
Integrated/Separated Explosion-Proof Ultrasonic Level Gauge
HR9100E
-
HighReach Measuring & Controlling System Co.,Ltd
1. Safety / use of die-cast aluminum alloy waterproof, explosion-proof shell; the explosion-proof grade of the instrument reaches Exd (ia) IIBT4 2. stable and reliable / we choose high-quality module key components from the power supply Part of The Circuit Design Stable and Reliable Devices CAN Completely Replace imported Instruments. 3. Patented Technology / Ultrasonic Intelligent Software CAN with Carry OUT Intelligent echo Analysis, the without the any the debugging and OTHER Special Steps, the this Technology has The function of Dynamic Thinking, Dynamic Analysis 4. High precision / sound wave intelligent patent technology owned by our company, so that The accuracy of the ultrasonic level gauge is greatly improved, the liquid level accuracy reaches 0.3%, it can resist various interference waves, the failure rate is low, the installation is easy, and the maintenance is easy. The instrument is a non-contact instrument and does not directly contact with liquid. Users can use this manual to calibrate the instrument. 6. The protection level of multiple protection/instrument reaches IP65; all output and input lines have lightning protection and short circuit protection.
-
Product
Universal Development Board For The PCAN-MicroMod CPU
PCAN MicroMod Evaluation Kit
-
As a plug-in module, the PCAN-MicroMod represents a simple way of providing electronic circuits with I/O functionality and CAN connection. The configuration is carried out with a Windows program that transfers the configuration data to the module via CAN. Several modules can be configured independently of one another on a CAN bus.
-
Product
Temperature Measurement
K- TC8
-
The K-TC modules belong to the Influx K-series instrumentation range for CAN applications. The stackable K-TC is an ideal for those applications that require a large number of thermocouples for example vehicle durability, winter and summer testing.
-
Product
(8×16)-Ch Dual Pole 2A-250VAC Matrix
YAV90060
Matrix Switch Module
128 relays DPST double matrix (4×16). Switching up to 250Vac and 2A CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Pressure Transducers with CAN Bus Interface
P66
-
The Validyne model P66 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via CAN Bus provides remote zero and span adjustment as well as digital pressure readings in engineering units or pressure counts.
-
Product
2-Port CAN Module
AMAX-5495
-
2-ch CAN portSupport CAN2.0B, compatible with CAN2.0AData Transfer Rate: 1Mbits/sOptical isolation protection of 2,500 VDC ensures system reliability
-
Product
Switched Power Distribution Module, CAN Control
H730008FS
-
The intelligent Power Distribution Unit (PDU) H7300.08xx has two main functions:• Distributing the power to each device in a system• Switching on the devices sequentially, in order to minimize the inrush current from the switched power supplies, that might affect the contactors.The PDU has electrical monitoring of the load status in order to ease troubleshooting and maintenance tasks:• There are two light indicators per socket, to inform the user about:– Whether the plugged devices main switch is turned ON. This is helping to identify plugged devices with their main switch OFF, that therefore cannot be controlled by the PDU– Whether the power for the socket is ON. Therefore, (P ON) indicates that the PDU is giving power to the device.All the relays are CAN bus controlled.The unit has an extra power terminal block in order to extend to other units (connect more PDUs).
-
Product
CANbus Module
DS-MPE-CAN2L
-
The module implements a CAN protocol bus controller that performs serial communications according to the CAN 2.0A and CAN 2.0B specifications. The protocol uses a multi-master bus configuration for the transfer of frames between nodes of the network and manages error handling with no burden on the host processor. Error analysis features enabling diagnostics, system maintenance, and system optimization. A listen-only mode enables CAN bus traffic analysis and automatic bit-rate detection.
-
Product
48 Optocoupled Digital Inputs
YAV90321
Digital I/O
Input Voltage 3…42Vdc Isolated Inputs / Control >1000Vdc CAN Control (or Ethernet with Ethernet to CAN Gateway.) Drivers dll & VIs available.