Discharge
-
Product
FaithTech Regenerative High-power Programmable DC Load
FTR9000 Series
-
Shenzhen FaithTech Technology Co., Ltd.
FTR9000 series is a regenerative programmable DC electronic load. It not only has the function of traditional consumable load, but also cleanly feeds the energy consumed by traditional load back to the power grid to achieve the purpose of energy conservation. It can be widely used in new energy equipment testing, lithium ion, fuel and other battery discharge testing, automatic testing system, AC/DC, DC/DC and other one-way module product testing and aging. The product is equipped with rich communication, programming interfaces, color screens and a variety of text menu interfaces, which is easy to operate and intuitive. It is a common equipment in the power electronics, new energy, sensors, motor drives, system integration and other industries.
-
Product
Programmable DC Electronic Load
-
Four parameters, highlight VFD display.Resolution of voltage and current: 0.1mV/0.1mA.Four working modes: CV/CC/CR/CP.Three dynamic test function (up to 10KHz): continuous load switching mode, pulse load mode, toggle load switching mode.Ten groups automatic testing data files with each file 10 steps.Intelligent fan cooling, coding switch, built-in buzzer, non-slip feet .Complex current sequence list test mode .Remote sensing function.Battery discharging test mode.All modes turn on default
-
Product
PD Measuring System
TEM
-
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
Product
Cable Diagnostic Tools
-
For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.
-
Product
Partial Discharge Testing Equipment
PD-Analyser
-
This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.
-
Product
±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester
HBM-S1-B
-
High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm
-
Product
Inductive Sensor
HFCT Ø 30-39-50mm
-
Techimp HFCT is an inductive sensor for partial discharge measurements. It is suitable for on/off line PD tests on many electrical systems (cables, transformers, rotating machine, etc..). It has to be applied to the ground connection of the system to be tested.
-
Product
Portable Touchplate Wrist Strap Tester
-
Testing your ESD Wrist Strap system before handling electrostatic sensitive is extremely important. ESD events can go unnoticed by feel and sight. While a static discharge into a door knob (we’ve all done it!) can be thousands of volts, an ESD event can be as little as 10V, and you will not feel this. This is a no-frills, “go-no-go” type tester, but portable. Sure you could put this at your entry point, but where it really shines is in special remote applications. Keep one in your tool box, bag or Field Service Kit.
-
Product
Battery Internal Resistance Tester
HDGC-3915
-
HD Power Test Equipment Co.ltd
Battery Internal Resistance Tester is designed using the advanced AC discharge measurement method to test accurately voltage and resistance of battery. It is strictly designed to evaluate battery performance, state and life-time, which maintain all stationary power systems including Uninterruptible Power System. Battery Internal Resistance Tester can proceed the measurement in a group and in a single section of battery. With accurate testing of resistance and voltage, it gives an indication of battery capacity and technical status. The measurement data can be read on the instrument display directly. And it can also be uploaded to PC simply by using the USB drive. With the analyzing software, you could not only keep a record of the testing result but also have detailed analyzing for the status of batteries in different testing conditions.
-
Product
Analogue (1kV below) Insulation Tester
2132 IN
-
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test. ● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.
-
Product
ESD Test Simulator
ONYX16
-
The ONYX is a state of the art electrostatic discharge simulator available in 16kV or 30kV versions. It is the most ergonomic 30kV ESD gun without an additional base control unit that can be battery or mains operated. The easy to use touch screen, ergonomic design, modular RC units, multilingual interface, remote control software, built-in LED light and temperature & humidity display allows for trouble-free use of the ONYX in all types of test sites.
-
Product
Load Banks
-
The only way to be certain that your stationary batteries will perform to specification is to test the batteries’ capacity with a DC load bank / portable battery discharge tester.
-
Product
Transmission Line Pulse Testing
-
Transmission Line Pulse testing, or TLP testing, is a method for semiconductor characterization of Electrostatic Discharge (ESD) protection structures. In the Transmission Line Pulse test, high current pulses are applied to the pin under test (PUT) at successively higher levels through a coaxial cable of specified length. The applied pulses are of a current amplitude and duration representative of the Human Body Model (HBM) event (or a Charged Device Model – CDM – event in the case of Very Fast TLP, or VF-TLP).
-
Product
Non Contact River Monitoring System
RiverSonde®
-
The RiverSonde® is an affordable, non-contact monitoring system providing continuous surface cross-channel velocity profiles for streams, channels, and rivers. Data output from this system can be used as an index velocity in conjunction with other data sets or as model input for calculation of total water discharge (Q). It is also ideal for monitoring river movement during flood events and in disaster planning.
-
Product
Pressure Relief Valves
-
WITT is a manufacturer of safety relief valves or pressure relief valves. Safety relief valves respectively pressure relief valves or pressure safety valves are designed to protect against overpressure by discharging pressurised gases and vapours from pipelines, pressure vessels and plant components. Safety relief valves are often the last line of defence against explosion – and such an explosion could be fatal.
-
Product
Programmable Electrical Rule Checking tool
Calibre PERC
-
Calibre® PERC™, Mentor Graphics'' newest reliability verification solution is designed to address your advanced circuit verification needs for electrostatic discharge (ESD), electrical overstress (EOS), signals crossing multiple power domains, advanced ERC and other reliability concerns.
-
Product
Dual-Mode Charge Amplifiers
-
Dual-mode charge amplifiers represent a versatile solution for both piezoelectric charge mode and ICP® sensors. Among the advanced features offered by models 443B01, 443B02 and 2775C are an ultra-low noise floor, sensor fault detection, overload detection, a built-in calibration reference signal, and an RS-232 port for seamless computer control. Notably, model 443B02 features a long discharge time constant selection, ideal for capturing quasi-static events lasting several seconds, a capability particularly beneficial for ballistics and ammunition testing applications. Model 2775C features AC, DC, and servo outputs.
-
Product
Multi Disc Cluster Sprays
Code 96
-
The Parker Conflow Code 96 is a multi disc cluster spray with five spray heads within one compact unit, providing economical liquid discharge and coverage of a wide area
-
Product
Surge Voltage Generator
SSG 1500
-
Cable fault location with the BAUR SSG 1500. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
Product
Partial Discharge Inductor
Tracy
-
Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories
-
Product
PDIV Tester for EV Motor
PDIV 500-T
-
Shanghai Dean Electrical Co., Ltd
Differing from partial discharge with high frequency pulse which produce sound and light phenomenon, the power frequency AC voltage reaches a certain threshold, can only produce instantaneous current leakage around the tested sample, it can be detected through discharge capacity (unit: PC) to evaluate partial discharge phenomena..The instrument PDIV 500-T is designed to put samples such as enameled wire, insulation paper/film, and electric motor stator in the High temperature / humidity environment chamber, applying a power frequency voltage with a programed rising speed, and prefect ground connection must be guaranteed , through the coupling capacitor as the medium, the continuous detection of discharge capacity against the voltages will create formulation between the Voltages and discharge capacities (pc), the software will find the discharge voltage threshold called PDIV.
-
Product
Partial Discharge Detecting Systems
-
Hangzhou Xihu Electronic Institute
Cable PD detecting and positioning system, transformer PD detecting and positioning system, switchgear PD detecting and positioning system, GIS PD detecting and positioning systems.
-
Product
Battery Simulator
Battery Simulator
The battery simulator is used for testing satellite power supplies and is used in combination with a Solar Array Simulator and load systems (consumer simulation) for the validation and commissioning of satellite power supplies. Loads and power supplies in the battery simulator are operated in combination to represent a 2-square function and to simulate both charging and discharging of the battery.
-
Product
AVL Battery Test Systems
-
In modern electrified powertrains (xEVs), huge demands are placed on batteries. These electrochemical energy storage and conversion devices must meet market requirements such as long-lasting high power and energy performance, and dynamic charge and discharge processes.
-
Product
Partial Discharge and Tan Delta
PDIX Series
-
PDIX is a combined partial discharge and tan delta cable diagnostic testing system. By combining HVI’s VLF products with PDIX products, users can perform VLF AC withstand, partial discharge detection, and tan delta measurement on medium and high voltage cables, rotating machinery, and other apparatus with one integrated package fully supported by HVI & PDIX.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Battery discharge testers
-
The battery discharge testers are used to test batteries by discharging them in a specified mode: given resistive load, fixed discharge current, etc. Depending on the required power rating, various sizes are available from manually transportable testers to multiple electronically controlled units in a master/slave configuration. Five Series of standard models.
-
Product
Lightning Current Generator
-
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
Product
Charge Plate Monitor
-
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
Product
Battery Charger-Analyzer for small battery systems
Minicharger
-
The Minicharger is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries