Fault
-
Product
Battery Fault Insertion Unit
-
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
-
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
-
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
-
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
-
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
-
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
-
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A, Hardware Interlock
40-191B-012-HI
-
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
Fault Simulation
Concurrent Fault Simulator
-
TurboFault combines high performance, versatility and accuracy. It is highly competitive with hardware accelerators for classical test fault grading. It supports synchronous and asynchronous designs at the gate level, including tri-state gates, latches, flip-flops, single and multi-port RAMs, complex bus resolution functions, and User Defined Primitives (UDPs).
-
Product
PXI 16-Channel 4-Bus 2A Fault Insertion Switch
40-197A-002
-
This 16-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers.
-
Product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-302
-
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
-
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Fault Locator
REZAP MODULAR
-
REZAP MODULAR brings full REZAP functionality to fuse panels with severe space restrictions
-
Product
Cable Fault Meter
-
A cable fault meter can locate open power cables, either live or dead (without current), with voltages up to 300 V. A cable fault meter can locate cables, circuits, short circuits and ground wires. To perform these functions, it is not always necessary to disconnect electrically sensitive devices or to disconnect the power from the cable which is being tested. Many cable fault meter devices can also locate ferrous and non-ferrous metals, wood and plastic with high degrees of accuracy.
-
Product
Visual Fault Locators
MVFL Series
-
Shanghai Tarluz Telecom Tech Co., LTD
MVFL series Visual Fault Locators is meet the Class IIIA product, which is the easiest way to identify fibers from end to end and locate polished connector endfaces. Its red laser shines through most yellow-jacketed fibers to help you pinpoint breaks, bends, faulty connectors, splices and other causes of signal loss. The 1mW output power enable the MVFL has a reach of up to 5 km. MVFL seires VFL locates faults visually by creating a bright red glow at the exact location of the fault on single mode (SM) or multimode (MM) fibers. Due to its small size, lightweight and simple but proven design, the MVFL can accompany you anywhere In your pocket or belt pouch in harsh environment
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
-
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
Fault Locators
-
For the first time, you can detect the type of fault and locate the position of an electrical fault that causes intermittent or persistent circuit breaker trips, thus giving you the critical information needed to reduce call backs for circuit breaker trips.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
-
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
Visual Fault Locator
FFL-210-U
-
FFL-210-U Visual Fault Locator is equipped with a 650 nm high power visible laser diode,can be operated in CW (continuous) or MOD (1Hz modulation) mode. There are two LED indicators:RED & GREEN; the RED one shows the operating mode of the Laser Diode output signal, and the GREEN one indicates low battery level. FFL-210-U is housed in a pocket-size, rugged metal casing, comes with a carrying pouch.
-
Product
Pen-based Fault Locator
-
*Find the breakpoint, bending or cracking*Find the fault of OTDR dead zone*Identification of fiber from one end to other end*Universal adaptor*Testing distance up to 8km*Lightweight, red laser output, both SM and MM available
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A
40-194A-002
-
The 40-194A-002 is a 7-Channel Fault Insertion switch with two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Mobile Cable Fault Location System
Syscompact 2000
-
Fault location with Syscompact 2000. The Syscompact 2000 is a multifunctional cable fault location system designed for modular 19" rack technology. The integrated surge and test generator is used for cable and sheath testing as well as for precise location of high-resistive and intermittent faults. The SYSCOMPACT 2000 is preferably used in low- and medium-voltage networks for fault location up to a cable lengths of 65 km. * Fast and reliable * Precise, dependable cable fault location High performance * high voltage unit* Integrated proven cable fault pre-location methods
-
Product
2.5mm Visual Fault Locator
3105
-
Anfkom International Co.,Limited
The 3105 Pen type VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network. It includes:Finding the breakpoint, poor connections, bending or cracking in fiber optic cables.Finding the faults of OTDR dead zoneEnd-to-end visual fiber identification
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
-
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
-
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Cable Fault Location System
BAUR Syscompact 2000 Portable
-
Cable fault location system Syscompact 2000 portable. The cable fault location system Syscompact 2000 portable is used for precise location of high-resistance and intermittent faults in low and medium voltage cables.* Fast and reliable* Precise, dependable cable fault location* High performance high voltage unit* Integrated proven cable fault pre-location methods
-
Product
Fuse Circuit Breaker and Fault Finder
-
Shanghai Beha Electronics Co., Ltd.
*is a Fuse and Fault Finder which comprises of two parts: The Receiver and the Transmitter.*Locating and tracing of cables*Finding Circuit Breaker/RCD
-
Product
Pipeline & Cable Fault Locator
TM2000
-
TM2000 Pipeline & Cable Fault Locator is designed for the Underground utilities route locating, the depth measuring and disatance tracing.
-
Product
Overhead Fault Location
-
Schweitzer Engineering Laboratories, Inc.
Overhead faulted circuit indicators include easy-to-spot displays to help direct line crews to the faulted line sections—enabling faster restoration of power and improved customer uptime.





























