Chemiluminescence Ammonia Analyzer
Model T201
-
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.The Model T201 achieves its remarkable stability by means of an AutoZero valve which measures and corrects for zero noise. Multiple self-checks are performed continuously to insure maximum up-time while an innovative sample path, plumbed with specially conditioned materials, preserves the NH3 sample and reduces interferents to a minimum. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection.The Model T201 comes with the Numaview™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Synchro to Digital-Resolver to Digital Converters
HRDCK-HSDCK
Digital / Synchro Converter
Computer Conversions Corporation
HSDCK and HRDCK series are the highest accuracy, miniature tracking synchro and resolver to digital converters in the marketplace. They are designed specifically for ultra precise requirements in the most demanding industrial and military applications.
-
Product
UV Fluorescence TRS Analyzer
Model T102
-
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
Product
5 Channel DAC FMC Module
DACNF05 – HPC
-
Sundance Multiprocessor Technology Ltd.
The RFM-DACNF05 is a five channel Digital to Analog converter FMC which complies with VITA 57.1-2010. Each channel provides 16-bit single-ended input and one DC coupled differential analog output with 1 – 500MHz sampling speed based on Maxim MAX5888A. A single-ended external input or output clock is provided. The direction of the clock is programmable from the FPGA of the FMC carrier board.
-
Product
Single Phase DC Injection Set Kit
PDC120A/PDC200A
-
PDC120A/PDC200A Single Phase DC current injection set kit is portable test set which could generate DC current for the various testings in railway transportation, HVDC converting stations, etc.
-
Product
Color Measurement With Line Scan Cameras
-
The Chromasens line scan cameras offer new approaches for the color-accurate capture of objects. The chromaPIXA has an internal FPGA-based color calculator which converts the color information of the CCD sensor on-the-fly into standard output color spaces. Algorithms are used which allow a more precise transformation than the usual 3x3 matrix transformation.
-
Product
PXIe-7861, Kintex-7 160T FPGA, 16-Channel AI, 1 MS/s, PXI Multifunction Reconfigurable I/O Module
786671-01
Multifunction Reconfigurable I/O
PXIe, Kintex-7 160T FPGA, 16-Channel AI, 1 MS/s, PXI Multifunction Reconfigurable I/O Module - The PXIe-7861 features a user-programmable FPGA for high-performance onboard processing and direct control over I/O signals for complete flexibility of timing and synchronization. With 16 analog input channels connected directly to a Kintex-7 160T FPGA, you have ample space to design applications that require precise timing such as hardware-in-the-loop testing, custom protocol communication, sensor simulation, and high-speed control. The PXIe-7861 features a dedicated A/D converter (ADC) per channel for independent timing and triggering. This design offers multirate sampling and individual channel triggering, which are outside the capabilities of typical data acquisition hardware. The PXIe-7861 also includes peer-to-peer streaming for direct data transfer to other PXI Express modules.
-
Product
RS232 RS485 RS422 Serial To Ethernet Modbus Converters / Device Servers
-
In the past two decades, legacy serial communication protocols such as Modbus have merged rapidly with modern TCP/IP communication, yielding benefits including widely available infrastructures and greater distance, reliability, and flexibility. CommFront offers a range of industry-proven, easy-to-use serial to Ethernet converters and device servers, both hardware and software types. The applications of our serial to Ethernet converters include acting as a device server or a Modbus RTU/ASCII to Modbus TCP protocol converter; extending serial ( RS232 / RS485 / RS422 / TTL) communication distance over Ethernet network; controlling serial devices from remote Modbus TCP software or Modbus RTU master via Ethernet network; making a wide variety of M2M communication applications possible by enabling client access independent of any operating system or proprietary protocol; and converting conventional serial data network into TCP/IP network, etc.
-
Product
Generic RF ATE Test
-
The Generic RF ATE is developed to test the Radar and Radar Subsystems. The ATE is primarily built using an instrumentation control, precision RF routing systems and rack mounted test instruments. Generic RF ATE system enables measurement of parameters of Radar equipment such as Local Oscillators, Waveform Generators, Up and Down Converters, Analog Receivers, Array Group Receiver Units, TR Modules. The ATE is configured to test the Radars upto 18GHz frequency range.
-
Product
PCIe-Mini
PCIe-Mini-AD8200
-
8 Channels 16-bit A/D converter Simultaneously Sampled• Fast throughput rate: 200 KSPS for all 8 channels• 8 Channels SE or 4 PSEUDO Differentials• Single-ended or 4 differential channels• True bipolar analog input ranges: ±10 V, ±5 V, selection applies to all Channels• Analog Input Clamp Protection• 1MΩ Analog Input Impedance• Programmable 2nd Order Anti-alias Analog Filter• Over-sampling capability with digital filter• 8Kx16 SRAM• PCIexpress compliant
-
Product
mAEStro Audio Digital to Analog Converter
-
The mAEStro ADAC-100 receives AES/EBU (AES3) or S/PDIF digital audio and converts it to two channels of analog audio. It automatically detects sample rates up to 96kHz with low-jitter clock recovery. Two balanced line-level audio outputs are provided on XLR connectors on the rear panel. For convenient monitoring, a stereo headphone mini-jack and volume control are provided on the front panel.
-
Product
Rad-Hard Power Management
-
ST offers a comprehensive range of QML-V rad-hard power management solutions for space applications including linear voltage regulators (low-dropout regulators), point of loads (switching DC/DC converters), PWM controllers, gate drivers, and an industry-unique integrated current limiter.
-
Product
SparkFun I2S Audio Breakout
MAX98357A
-
The SparkFun I2S Audio Breakout board uses the MAX98357A digital to analog converter (DAC), which converts I2S (not be confused with I2C) audio to an analog signal to drive speakers. The I2S Audio Breakout converts the digital audio signals using the I2S standard to an analog signal and amplifies the signal using a class D amplifier which can deliver up to 3.2W of power into a 4Ω load. The board can be configured to output only the left channel audio, right channel, or both.
-
Product
VLSI Test Systems
Test System
50/100 MHz clock rate50/100 Mbps data rate1024 I/O pins (Max :1280 I/O pins)Up to 1024 sites Parallel testing32/64 M pattern memoryVarious VI sourceFlexible HW-architecture (Interchangeable I/O, VI, ADDA,)Real parallel trim/match functionTime & frequency measurement unit (TFMU)High-speed time measurement unit (HSTMU)AD/DA test optionSCAN test option (max 1G M/chain)ALPG test option for embedded memorySTDF tools supportTest program/pattern converter(J750, D10, V50, E320, SC312, V7, TRI-6020, ITS9K)User friendly windows 7 environmentCRAFT C/C++ programming languageSW (Software) same as 3380P & 3360P
-
Product
Analog to Digital Video Converter/Embedder
SDI Pro VADC-100
-
The SDI Pro VADC-100 converts composite analog video to SDI video and embeds two channels of analog audio.
-
Product
Embedded LO Capability
S97084B
-
The S97084B tunes the analyzer’s receivers to the output frequency of the converter under test without the need for access to internal LOs or a common reference signal
-
Product
12 A/D Channels (±25mA FSR); 24-bit Sigma-Delta
AD3
-
Module AD3 features 12 channels with up to 24-bit Sigma-Delta A/D converters for each individual channel. The maximum programmable, expected full-scale range input for the AD3 module is ±25 mA respectively. The A/D converters have programmable sample rates of up to 256 kHz.
-
Product
RF & Microwave
-
Data Patterns has a strong RF and Microwave engineering capability, featuring a team of enthusiastic engineering talent, substantial investments in RF test and measuring instruments, and attitude to utilise the latest technologies.An in-house manufacturing capability and an insatiable demand for fulfilling requirements of Radar, Electronic Warfare and Communication domains, Data Patterns has developed a whole line of building blocks including TR Modules, Up and Down Converters, Power Amplifiers, Transmitters, Combiners and Dividers for specific requirements. A list of products is given below.
-
Product
Sensor Amplifier
UVM-SB
-
This is the relay amplifier box for the multi-point type UV monitors. Received UV light intensity is converted to electric signal for transmission. This allows distance between the light receiving inlet and the controller to 10 meters maximum.
-
Product
DC-DC Charge Pumps
-
Charge pumps – inductorless boost converters – from ams operate at up to 90% efficiency.
-
Product
isoPower
-
Analog Devices isoPower® technology utilizes proprietary iCoupler® chip scale transformers to integrate isolated dc-to-dc converts with data isolation into a single package. This enables designers to implement isolation in designs without the cost, size, power, performance, and reliability constraints found with optocouplers. With more than one billion channels shipped into the field, these magnetically isolated products are a safe, reliable and easy-to-use alternative to optocouplers.
-
Product
Temperature and Humidity Bar Type Transmitter
T3417
-
Relative humidity, temperature sensors at 700mm stem. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Frequency Converter Upwards
UPCONVERTER 10 GHz VXI
-
The UPCONVERTER 10 GHz control software is VXI Plug & Play and does not depend on the module version. The software allows for automated calibration and verification of the main characteristics of the device.
-
Product
Transmitter (Export Only)
SMDB
-
The input section features the unique servo bias input circuitry with a standard TA5M type jack for use with electret lavaliere mics, dynamic mics, or line level signals. A DSP-controlled analog audio limiter is employed before the A-D converter. The limiter has a range of more than 30 dB for excellent overload protection and a dual release envelope that makes the limiter acoustically transparent while maintaining low distortion. The limiter recovers quickly from brief transients, with no audible side effects, and also recovers slowly from sustained high levels to keep audio distortion low while preserving short term dynamics.
-
Product
Comb Generator, 10 MHz to 67 GHz
U9391G
-
The Keysight Technologies, Inc. U9391G comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
Product
High Precision Compression Type Load Cell
ZR
-
A high-precision compression-type load cell is a sensor that accurately measures compressive (pushing) forces, designed for applications requiring very tight accuracy and reliability. It works by converting a downward force into an electrical signal, often using strain gauges to measure deformation, and is used in demanding fields like calibration, manufacturing, and medical equipment.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
System Control Modules for 34980A
-
The 34980A System and Control modules provide additional measurement and control capabilities that are typically used in test applications. Choose from modules that include digital I/O with programmable polarity, D/A converter with onboard memory to create waveforms, and frequency counter/totalizers.
-
Product
PXIe Down Converter: 4 Channels, 2-16 GHz RF, 0.01-2.4 GHz IF
M5201A
Downconverter
Single-slot PXIe low-IF downconverter module with a 2 to 16 GHz RF input frequency range and 0.01 to 2.4 GHz IF range
-
Product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
-
High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)