Product
Turns Ratio Testers
TRT Advanced Series
-
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
Product
Synchro/Resolver to Linear DC Converter
DC Converter
NAI offers a variety of Synchro/Resolver Converters that continuously transform Synchro or Resolver inputs into digital form. These solid-state modules provide resolution to 16-bit and accuracy to 19.8 arc-seconds, and are error-free up to the maximum specified tracking rate. They are transformer-isolated and operate over a frequency range from 47 Hz to 10 kHz. The modules are specifically designed for rugged defense and industrial applications.
-
Product
Server Products
-
Driving Data Center Transformation Through Innovation. Trust, reliability, proven performance. There are reasons Intel is a global leader and preferred provider of server technology and products. Intel understands the needs of the modern data center and harnesses its years of experience and design expertise to deliver a broad portfolio of innovative server products, systems, and solutions to help businesses grow and be competitive in the market.
-
Product
64-Channel 500kSa/s USB Modular Multifunction Data Acquisition
U2356A
Data Acquisition Module
The U2356A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2356A to simulate simultaneous analog input acquisition.
-
Product
Transformer Demagnetization Tester
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
Product
Horn Antenna
-
Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.
-
Product
Split Core Current Transformers
LZCK-55
-
Beijing GFUVE Electronics Co.,Ltd.
Outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
-
Product
Automated Test Equipment
-
Viewpoint Systems offers design verification and manufacturing quality inspection systems to help customers reduce human error in repetitive tests, increase testing speeds, and ultimately get products to market faster at a lower cost. Viewpoint Transforms Test from Design to End-of-Line. Our R&D test systems are designed with the flexibility to validate ever-changing prototypes while accelerating your development schedule.
-
Product
Incremental Transformer Solutions
TRANSPORT X
-
The Kelman TRANSPORT X is a compact portable Dissolved Gas Analysis (DGA) system which can be used to analyze oil samples for all dissolved fault gases and moisture. If abnormal levels are detected, it further provides a diagnostic using various IEEE/IEC approved interpretation rules.
-
Product
AC/DC Laboratory Power Supplies
-
PeakTech Prüf- und Messtechnik GmbH
This AC / DC laboratory power supply has two separately adjustable outputs which can dispense AC/DC voltages from 0 - 30 V as well as DC/AC current 0 - 6 A. Due to the possibilities offered by this device, it is also suitable for the maintenance of small AC circuits, transformers and lights.
-
Product
Contact Resistance Tester
JYL-200B/100B
-
Product description: JYL-200B/100B contact resistance tester can measure contact resistance of high voltage switches and circuit breakeres, also can test primar side resistance of transformer and grounding wire in groups
-
Product
Transformer Polarity Checker
865
-
This instrument is used to check the correctness of polarity markings on transformers. In operation, the two leads carrying the test current are connected to one of the transformer windings. The other two leads from the indicating meter are connected to the other winding.
-
Product
HV AC Voltage Test Systems
-
Fivestar HV Testing Equipment Co., Ltd.
FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.
-
Product
Transformer Performance Tester
JYM
-
JYM insulation resistance tester is used for on-site insulation resistance measurement. The instrument has built-in positive and negative bipolar high-voltage power supplies, with large output power and strong load capacity. It is suitable for insulation resistance measurement of samples with large capacitance, such as power transformers and cables.
-
Product
External DC12V Power Gem Tester
-
Fuzhou Zhongtuo Optoelectronic Co.,Ltd
12V power supplies (or 12VDC power supplies) are one of the most common power supplies in use today. In general, a 12VDC output is obtained from a 120VAC or 240VAC input using a combination of transformers, diodes and transistors.
-
Product
SELV laboratory power supplies
-
PeakTech Prüf- und Messtechnik GmbH
A linearly regulated, stabilized laboratory power supply with a safety transformer. It is ideally suited for teaching aids, schools and universities and offers safe use but also a very good price / performance ratio.
-
Product
Inverter
INV 500VA to 10kVA
-
*19 "inverter up to 4000VA*Efficiency> 88%*Can be connected in parallel*Without 50Hz transformer*robust IGBT output stage
-
Product
AC Reference Generators
SR22
-
Computer Conversions Corporation
The SR Series are miniature, low cost AC reference generators designed to supply 26 or 115 volt excitation to synchros or resolvers in military and industrial control applications. They accept +/-15V DC and provide up to 5VA of transformer isolated output power. These converters are packaged in PC card mounting modules 2.6”x3.1”x1”H
-
Product
DC Resistance Tester
DCSS502BC
-
Resistance meter is designed to measure copper resistance of transformers, wires, cables, other conductors and other coil products etc. It is widely used of low resistance measurement of switches, heater wires, transformers, relays, motors, electric films and PC circuit boards, wires, cables, etc. With reliable Good/ NG judgement, it is a premier resistance meter for the use in production line or QC department.
-
Product
Transformer Testing
-
Haomai Electric Power Automation Co.,Ltd.
1)Test Standard:IEC60076 & IEEE C57.12.90 2)Voltage ratio measurement of transformer 3)Turns ratio measurement of transformer 4)Group vector measurement of transformer
-
Product
Gas-insulated AC Test System
-
Yangzhou Power Electric Co., Ltd
The test system is used to do AC voltage withstand test and PD measurement for high voltage insulation products, combined electrical equipment, instrument transformers, etc.
-
Product
Decoking System
-
Discover how our hydraulic decoking systems have transformed hydraulic decoking into an increasingly reliable, efficient and automated process.
-
Product
USB-485/2, 2-Port, USB, RS485/RS422 Serial Interface Device
778476-02
Serial Interface
The USB‑485/2 interface transforms your USB port into a single asynchronous serial port for communication with RS485 and RS422 devices. You can use a USB‑485/2 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Equipment Condition Indication
MetalSCAN
-
Condition indication in real-time, so you can schedule maintenance at the right time.MetalSCAN is the leading real-time, on-line condition indication technology designed to alert equipment operators to bearing and gear damage, long before equipment failure. Nothing else comes close. Its advanced capabilities deliver knowledge that transforms equipment failure to predictable and avoidable high cost events. Use MetalSCAN to optimize maintenance schedules, reduce repair costs, increase reliability and improve safety.
-
Product
Oil Purifier
-
Weshine Electric Manufacturing Co., Ltd
Weshine represent the absolute best in the field of transformer oil regeneration and corrosive sulfur removal. Several new features developed inhouse by our research and development department result in the state-of-the-art transformer oil regeneration equipment. Supplemented by our unique corrosive sulfur mitigation process integrated directly into the regeneration process.
-
Product
ANSI Relaying Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
Four Channel Arbitrary Waveform Generator 2.5GS/s 16Bit 1GS Mem 4CH 8 Markers AWG
P2584M
Waveform Generator
The Proteus P2584M, is a PXIe based, 2.5GS/s, four channel arbitrary waveform generator offering technologically advanced options and configurations such as, a dual channel 2.7GS/s digitizer with 9GHz bandwidth, to transform the instrument to an arbitrary waveform transceiver. The P2584M offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
Product
Current Transformer
-
OutputDC 10VLinearityAs graph aboveApplied VoltageAC 2000V, 1min (between aperture and terminals)ImpendanceDC 500V, over 100M (between aperture and terminals)Fire Retardant Level94V0Output Terminals2.54 mm pinAnti-vibration50 Hz 5G
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.