-
product
Instrument Maintenance & Diagnostics Software
Instrument Maintenance and Diagnostic Software monitors instrument health and provides email-based alerts, notifying you when to consider replacing key consumables, when to perform preventive maintenance, and when an instrument stops running anywhere in your lab. This software is also designed to track inventories, manage schedules, aggregate data, provide resource visibility, and integrate with other lab systems.Monitoring is available for a wide range of instruments and allows you to capture lab-wide instrument utilization data across all of your workflows. These capabilities are designed to deliver reduced downtime and sustained instrument performance, driving simplification, optimization, and transformation of lab operations.
-
product
Load Length Meter
Design for finding out the total voltage of neon tubes in a circuit, help to Choose correct rating of neon transformer;- Easy to use just like a neon transformer;- With color LED indicators, clearly shows the test result;- With build-in over voltage protection circuit.
-
product
Open Loop Current Sensor
C03 30A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
STDETransformer Demagnetizer
STDE
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
product
GPIB-RS485, GPIB Instrument Control Device
779733-04
Serial, RS485/RS422 GPIB Instrument Control Device - The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 … serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.
-
product
Distributed Control Systems
As the heart of plant-level digitalization, ABB's Distributed Control Systems (DCS) are designed to transform your multi-faceted, 24/7 process operations. Our market-leading control architecture constantly monitors and drives plant productivity, maximizing asset utilization, process efficiency and production quality. A focus on availability, safety and cyber security ensures the protection of your people, assets and equipment. And by maintaining tight controls over raw material consumption, plant energy levels and waste by-products, ABB DCS solutions help to significantly reduce environmental impact.
-
product
Transformer Winding Resistance Meters
TWA Advanced Series
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
product
LCR Meter
SS10X Series
LCR Meters are basic passive component testing equipment, can be used in quality management department or production process for quality inspection. Like as: transformer, inductor, resistor, capacitor, relay, motor, generator, electric valve, contactor, cable, wire, etc. This series LCR meter, offering different kind of testing fixtures, can improve testing precision and reduce the difference value of error code, being an economical and useful basic testing instrument.
-
product
Variable Transformer DC Power Supplies
Variable DC power supplies are AC to DC power supplies with a variable DC output. The output can be varied with a Variable Transformer (also known as variac). The Variable Transformer can be adjusted manually or with a motorized control. The AC input power can be single phase or three phases. With single phase AC input, the DC output ripple is very high (50%). With three phase AC input, the DC output ripple is low (5%). This would be a key benefit for selecting three phase AC input instead of single phase.
-
product
Transformer Performance Tester
JYM
JYM insulation resistance tester is used for on-site insulation resistance measurement. The instrument has built-in positive and negative bipolar high-voltage power supplies, with large output power and strong load capacity. It is suitable for insulation resistance measurement of samples with large capacitance, such as power transformers and cables.
-
product
USB-485/4, 4-Port, USB, RS485/RS422 Serial Interface Device
778476-14
The USB‑485/4 interface transforms your USB port into a single asynchronous serial port for communication with RS485 and RS422 devices. You can use a USB‑485/4 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
product
Mobile Computing Solutions
Advancements in mobile technology are transforming field service operations. Mobile computing devices provide real-time data access, enabling field workers to make informed decisions on the spot. This streamlines workflows and improves efficiency to ultimately optimize quality and increase productivity.
-
product
PCIe-Mini Module
PCIe-Mini-1553-2
The ALPHI PCIe-Mini-1553-2 uses DDC Total-Ace communication device as its 1553 bus controller, or remote terminal with concurrent Bus monitor terminal. Dual controller has a Dual redundant channel with built in transceivers and transformer. The controller has the capability to emulate up to 31 RT addresses simultaneously. The PCIe-Mini-1553-2in RT mode can filter on RT address, T/R, Subaddress. The PCie-Mini-1553-2 is offered is extended temperature. The board format is a full PCIexpress Mini board.
-
product
Insulating Oil Testing
Weshine Electric Manufacturing Co., Ltd
Weshine represent the absolute best in the field of transformer oil regeneration and corrosive sulfur removal. Several new features developed inhouse by our research and development department result in the state-of-the-art transformer oil regeneration equipment. Supplemented by our unique corrosive sulfur mitigation process integrated directly into the regeneration process.
-
product
4 Way Fiber Optic Return Path Receiver (low Optical Input)
MX4RR-LI
The MX4RR-LI transforms return optical signals to RF signal output. The standard 1U chassis integrates 4 independent receiver modules, it can receive up to 128 return optical signals from burst mode mini-nodes or services for 128 RFoG optical network units (ONU)-Mini-Nodes.
-
product
Epoxy Resin Silicon Rubber Outdoor Voltage Transformer
JDZW-10RG
Beijing GFUVE Electronics Co.,Ltd.
Outdoor voltage transformer of the type JDZW-10 is single phase and epoxy resin silicon rubber insulated product, it's used for metering electric energy, voltage control and relay protection in 50/60HZ rated voltage less than 12kV electric system. It can be used for medial voltage AIS, or can be used for medial voltage switchgears. They can operate in all kinds of environments (such as wide range temperature (-50~70℃), high altitude, high humidity, high pollution or salt). This model JDZW-10 outdoor voltage transformer is also as voltage source to supply 220V voltage.
-
product
Transformer Tester
MOTOMEA Distribution Transformer Test Systems: Routine Testing for Production (EOL) and Quality Assurance (QA). Type Testing at Laboratory (R&D)
-
product
Primary Injection Kit
Prima Series
Prima Series is designed for Primary Current Injection Testing of Current Transformers, Protection Relays & Circuit Breakers during their Factory Test, Commissioning and Routine Testing.
-
product
Digital Multimeter
DM3058/E
DM3058 / DM3058E is an economical 5.5-digit digital multimeter. It is designed for the test requirements of high accuracy, multi-function and automatic measurement. It integrates the functions of automatic measurement, multiple mathematical transformations and any sensor measurement. It provides USB, GPIB (DM3058 only), LAN (DM3058 only) and RS232 interfaces.
-
product
Reactive Energy Regulator
MASTER
Lifasa - International Capacitors, SA
It measures the reactive power needs of an installation and gives the corresponding capacitor connection and disconnection orders to keep the cos φ preset. At the same time it allows to measure the main parameters of an installation (voltage, current, harmonics, active power, reactive power, etc.), by using 1 or 3 current measurement transformers.
-
product
16-Channel 250kSa/s USB Modular Multifunction Data Acquisition
U2351A
The U2351A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2351A to simulate simultaneous analog input acquisition.
-
product
Fiber Optics
The Neoptix product line includes fiber optic temperature sensors for transformer windings temperature monitoring and for laboratory, industrial, and medical applications.
-
product
Current Probes
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
product
I2C Isolators
Analog Devices’ family of isolated I2C isolators support a complete isolated I2C interface. This portfolio is based on our iCoupler® chip scale transformer technology. iCoupler is a magnetic isolation technology with functional, performance, size, and power consumption advantages compared to optocouplers. By integrating iCoupler channels with semiconductor circuitry, our technology enables a complete, isolated I2C interface with a small form factor. Our I2C isolators covers applications such as central office switching, networking, and power over Ethernet.
-
product
Rectifier Assemblies for Crane Applications
CEHCO manufactures Transformer Rectifier Assemblies for Crane Applications. We offer standard products and customized solutions.
-
product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
product
Protection Device Testing
The Motwane Manufacturing Company
Power system protection is a branch of electrical power engineering that focuses on protecting electrical power systems to detect and isolate faulty parts. The objective is to keep the power system stable by separating only the defective components while keeping the rest of the network in operation. The device protects the transmission lines, generator transformer, and other electrical apparatus from multiple faults.
-
product
1 A DIGITAL MILIOHMMETER
MO-2Ke
The MO-2Ke digital low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of contacts, switches, transformer and motor windings, etc., using test currents from 1 mA up to 1 A.It uses the Kelvin-type (4-terminals) measurement principle, thus eliminating errors caused by lead and contact resistances.Resistance readings are shown in the alphanumeric display with up to a 4 digit-resolution. It allows to measure resistances of up to 2 kO, with resolution of 0.01 mO.Measurements accuracy is guaranteed by the state-of-the-art system for signal-amplification, offset-free and with long-term stability.
-
product
Transformer Insulation Testing
The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).
-
product
Transformer Turns Ratio Meter
TTRM 102
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.





























