Insertion Loss & Return Loss
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
Multiplexer Module
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
Two-Way Optical Loss Test Set
KI23427OLF-INGAAS-APC
-
A Two-Way Optical Loss Test set (OLTS) that's perfect for medium to ultra high fiber count loss, length and optical return loss testing applications on single mode fiber with an APC connector at triple 1310 / 1490 / 1550 nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use. The 650 nm VFL is on a separate port.
-
Product
Signal, Insert Bundle, ITA, QuadraPaddle, SIM, Right Angle and Pass-Thru
510181107
SIM Insert
Signal, Insert Bundle, ITA, QuadraPaddle, SIM, Right Angle and Pass-Thru.
-
Product
Signal/Mini Power/ Mini Coax, Module Insert, ITA, i2 MX, TriPaddle, 8/8 Position
510144005
ITA Module
Signal/Mini Power/ Mini Coax, Module Insert, ITA, i2 MX, TriPaddle, 8/8 Position
-
Product
Magnet & Integrated Variable Temperature Sample Space With DR Insert
-
Adapted MCK model DR inserted into 50 mm 1.6 K300 K VTI VTI cooling power used for condensing stage of DR Versatile solution as the magnet system can also be used with other inserts and measurement probes including He3, heated probes, rotator, VSM etc.
-
Product
Channel Insertion & Encoding
-
ATX’s encoder products provide a cost-effective and space-efficient solution for digital transmission and/or insertion applications. ATX’s fully integrated wall or rack mount “single unit” line of products are ideal for inserting security camera video into MDUs, inserting barker or information channels into hotels and other commercial properties, for digital simulcast applications, and for digital delivery of PEG or hub site specific programming.
-
Product
Free Room Temperature Bore magnet with Insertable DR
-
Room Temperature magnet bore 50 mm sample space in DR Suitable for use with Leiden DR type CF200, CF450, CF650 or CF1000 DR
-
Product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
Fault Insertion Unit
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
Product
Adapter Rails (for High Speed Inserts), i2MX, Receiver, 88 Pos, 11 Slot
510143001
Receiver
Allows use of SIM VTAC patchcords in an i2MX receiver. Accommodates 11 single-slot inserts.
-
Product
Two-Way Optical Loss Test set
KI23422OLV-INGAAS
-
A Two-Way Optical Loss Test set (OLTS) that's perfect for medium to ultra high fiber count loss, length and optical return loss testing applications on single mode fiber at 1310 / 1550 nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-193A-002-HI
Fault Insertion Unit
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
4 Way Fiber Optic Return Path Receiver (low Optical Input)
MX4RR-LI
-
The MX4RR-LI transforms return optical signals to RF signal output. The standard 1U chassis integrates 4 independent receiver modules, it can receive up to 128 return optical signals from burst mode mini-nodes or services for 128 RFoG optical network units (ONU)-Mini-Nodes.
-
Product
VTAC Right Angle Insert
-
Modular and compact, VTAC right angle inserts are used to provide a high speed data connection to a PCB.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
Silicon Steel Sheet Iron Loss Tester
DX-30SST
-
DX-30SST Silicon Steel Sheet Iron Loss Meter adopts SCM technique and analog electronics technique, the magnetic circuit of permeameter adopts low loss silicon steel iron core, it is a small tester for measuring the characteristics of silicon steel sheet, met the requirements of tracing the brand of silicon steel sheet.
-
Product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A
40-192A-012
Switch Module
The 40-192A-012 is a PXI fault insertion switch using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
Digital Iron Loss Tester
VDW 2065A
-
VEER make Digital Iron Loss Tester VDW-2065A is portable & easy to use Instrument which is very useful to find Watt loss of Electrical Steel immediately. Internationally accepted standard method of testing is Epstein Frame method which needs 30mm x 305mm size & min. 250g material for testing. Stamping And Laminations cannot be tested on Epstein Frame because of size. So, we have designed a direct reading type Single Sheet Tester Called Digital Iron Loss Tester VDW-2065A. It provides very fast testing of final products like Stamping, El & other laminations etc.
-
Product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch
40-190B-002
Fault Insertion Unit
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Guarded Insert For PPMS®
-
The Lake Shore guarded insert can be used alone or with one of our PPMS Hall measurement packages that include the MeasureReady® M91 FastHall controller. Cut your measurement time up to one-half with the M91. Measurements are so fast that time-dependent misalignment errors are eliminated using the patented FastHall™ measurement technique.
-
Product
RETURN PATH SIGNAL GENERATOR
TG-1215
-
Circuit Method : Individual or Simultaneously. Frequency : 20/30/40/50/60MHz(5carriers). LOW BATTERY CONSUMPTION. COMPACT SIZE DESIGN. OUTPUT LEVEL ADJUSTABLE. OUTPUT LEVEL DISPLAY. MAX. 5CARRIES(individual or Simultaneously). PORTABLE TYPE(weight less than 500g). APPLICATIONS: Testing and aligning CATV return band. Testing and adjusting Internet return band.
-
Product
PXI-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module
778572-12
Signal Module
7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
Signal, Module Insert, ITA, i2 MX, TriPaddle ,33 Position
510144006
ITA Module Insert
Signal, Module Insert, ITA, i2 MX, TriPaddle ,33 Position.
-
Product
Receiver, i2 MX, 22 Slot VTAC/SIM Insert, EMI
310130113
Receiver
Receiver, i2 MX, 22 Slot VTAC/SIM Insert, EMI.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI 16x4 Signal Insertion and Monitor Matrix
40-525A-002
Matrix Switch Module
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also available in a 34x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system.
-
Product
VTAC Insert
-
The configurable VTAC high speed data insert features a data transfer rate of more than 12.5 Gbps per differential pair. Gold-plated, self-aligning contacts are specifically designed to reduce crosstalk to increase signal integrity during HSD transfers while maximizing cycle life.Each VTAC insert has a cycle life of over 150,000 without signal degradation.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Adapter Rails (for High Speed Inserts), i2MX, ITA, 88 Pos, 11 Slot
510144001
Adapter Rails
Allows use of SIM inserts in i2MX ITA. Accommodates 11 single-slot inserts.
-
Product
Iron loss Testers
ATS Series
-
Hunan Linkjoin Technology Co., Ltd.
Linkjoin Iron Loss Testers





























