Insertion Loss & Return Loss
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-212
Fault Insertion Unit
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
Fault Insertion Unit
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
Micro Coax/Micro Power, Module Insert, Receiver, I2 MX, 15 Position
510143009
Receiver Module Insert
Micro Coax/Micro Power, Module Insert, Receiver, i2 MX, 15 Position
-
Product
21-Ch 6A-250VA 2-Bus Fault Insertion
YAV90077
Fault Insertion Unit
21 channels 1 thread 6A 250V 2 Fault Insertion Buses Switching up to 250W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Entry Level Loss Tester
Model:OLT-20
-
OLT-20 Optical Loss Tester integrates laser source module and power meter module in one set, which can perform power testing and link loss testing in optic fiber network conveniently. The typical applications include fiber identification, attenuation and loss measurement, continuity verification and fiber link transmission quality evaluation for installation, routine inspection and daily maintenance of MAN, WAN and CATV systems as well as for lab test and research work.
-
Product
Optical Loss Test Set
KI 23400
-
A Bidirectional Optical Loss Test set (OLTS) that's perfect for medium to ultra-high fiber count loss, length & ORL testing. A pair of compact instruments set new standards of productivity, accuracy, and ease of use.
-
Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
The 42-205-008 (PXIe) is an 8-channel fault insertion switch designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. It is available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
Optical Return Loss Meter
ORL
-
•Four functions in one•Power meter and light source•Return loss meter and insertion loss meter•3 wavelength detection(1310/1490/1550nm)•Rugged, shock and water-proof for field use•Compact size, lightweight and cost-effective•Quick and easy to operate
-
Product
Loss Test Set
HPT-5100
-
The HPT-5100 represents a significant improvement in technology at a competitive price. This high performance loss test set has advanced features commonly found in instruments costing far more.
-
Product
VTAC, Insert Bundle, Receiver/ITA, SIM, Right Angle and Pass-Thru
610151106
SIM Insert
VTAC, Insert Bundle, Receiver/ITA, SIM, Right Angle and Pass-Thru.
-
Product
Advanced Loss Tester
OLT-55
-
ated with Stabilized Laser Source, Optical Power Meter, Optical Loss Tester, ORL Tester and Length Testing functions. It can perform automatic bidirectional loss test on single fiber with Pass/Fail assessment. With rich functions, flexible configuration and excellent user friendly design, OLT-55 is the ideal optical loss tester to completely evaluate the optical fiber link condition in FTTx, LAN and CATV network.
-
Product
20/26 Ghz Coax, Module Insert, Receiver, i2 MX, 5 Position
510143008
Receiver Module Insert
20/26 Ghz Coax, Module Insert, Receiver, i2 MX, 5 Position.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
Fault Insertion Unit
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
Product
Optical Loss Test Set
OLTS
-
Tests for the total amount of light loss on a fiber optic link.
-
Product
Simple Loss Test Kit
KI-TK054
-
660/650 nm source & power meter. Interchangeable HFBR connectors
-
Product
Two-Way Optical Loss Test set
KI23403OLV-INGAAS-APC
-
A Dual Two-Way Optical Loss Test set (OLTS) that's perfect for medium to ultra high fiber count loss, length and optical return loss testing applications on multimode fiber at 850 / 1330nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use. A multimode APC connector on this model is required for reliable ORL test performance.
-
Product
Micro Power Insert, Receiver, SIM, 2 Position, 2 Slot
510180102
SIM Insert
This insert contains 2 micropower contacts and is part of the Infinity Connector system. It is used in the 90 Series SIM Module and occupies 2 of the 34 slots in this module. This insert comes loaded with contacts. Individual contacts sold separately p/n 610142106.
-
Product
Low Loss Combiners
-
*Tunable or band specific low loss combining of Tx and Rx*Typical 0.7dB insertion loss*Optional second duplexer can be installed in the same tray*High power handling with low IM and insertion loss*AISG 2.0 compliant
-
Product
Quad Optical Loss Test Set
KI27624-INGAAS
-
A Quad Optical Loss Test Set used to test power, insertion loss, continuity and faults on multimode and single mode fiber optic systems at 850 / 1300 nm & 1310 / 1550 nm. In a small package, it provides a powerful optical multi-meter style solution to improve test flexibility and productivity.
-
Product
Transformer Loss Measurement Systems
-
Measurements International Ltd.
The Transformer Loss Measuring System stands as a pivotal tool in ensuring the quality assessment of transformers. It plays a vital role in accurately measuring and evaluating the transformer’s performance by assessing both its no-load loss and load loss. Understanding these losses is essential in determining the efficiency and overall quality of the transformer, offering valuable insights for maintenance and improvement strategies.
-
Product
Signal, Module, ITA, i2 MX, 84 position, QuadraPaddle, Crimp
510144002
ITA Module Insert
Signal, Module, ITA, i2 MX, 84 position, QuadraPaddle, Crimp
-
Product
Signal/Mini Power/ Mini Coax, Module Insert, Receiver, i2 MX, TriPaddle, 8/8 Position
510143005
Receiver Module Insert
Signal/Mini Power/ Mini Coax, Module Insert, Receiver, i2 MX, TriPaddle, 8/8 Position.
-
Product
64-Ch 1-Bus Fault Insertion
YAV91082
Fault Insertion Unit
64 channels 1 thread 2A 250V 1 Fault Insertion Buses Switching up 60W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
Loss Test Set, Return Loss Test Set
LTS1315, LTS1315R
-
The KD Optics LTS1315 is a combined mains / battery powered laser source and power meter designed to make attenuation testing in the field easy, reliable and most importantly, consistent. The LTS1315R incorporates return loss measurement (RLM) capability with the ability to switch very easily between dBrel and return loss.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.