Wind
See Also: Wind Tunnels, Anemometers, Wind Turbine, Wind Speed, Turbulence
-
product
AUTOMATIC WINDING TEST SYSTEM
VE9036SU
6 CHANNEL Microprocessor based Automatic Test System for Automobile Coils, Magnetos, Alternator, Motor Winding. Can Test : Impulse Winding Tester (IW), AC/DC HiPot, Insulation Resistance (IR), Inductance (L), DC Resistance (DCR)
-
product
Fiber Bundling Tester
DRK022A
Shandong Drick Instruments Co., Ltd.
By winding and unwinding the carbon fiber, the bundling of the carbon fiber is detected.
-
product
Coating Thickness gauges.
PELT gauges provide data for the precise control of exacting coating-applications including for automotive paints, wind turbine blade protective coatings, steel coil coatings, and shipping container anti-corrosion coatings. PELT gauges measure coatings on substrates including steel, aluminum, plastics, carbon fiber, composites, glass, and wood.
-
product
Magnet Testing
MHLS
The MHLS is extremely flexible to use thanks to its compact and robust design. The development of ever more efficient electric motors in areas such as automotive engineering and wind energy is playing an ever increasing role, where the highest precision and quality of the magnetic components used is crucial, particularly in the energy and mobility transition.
-
product
DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET
International Biological Laboratories
This test set provides a continuously variable output voltage at double frequency to test the insulation between turns of coils, layer to layer, terminals of windings with either uniform or graded insulation and also between the windings and earth, with graded insulation of both Distribution and Power transformers.
-
product
Pull tester with uplift kit and pulling plate
UPLIFT 2000
The Uplift portable tester was designed in conjunction with SPRI, for testing on the field the uplift resistance of adhesion. Easily test the attachment of the tile to underlayment and determine whether the uplift resistance performance meets the minimum wind load requirements.
-
product
Helix Virtualization Platform
Wind River® Helix™ Virtualization Platform consolidates multi-OS and mixed-criticality applications onto a single edge compute software platform, simplifying, securing, and future-proofing critical infrastructure solutions in the aerospace, defense, industrial, medical, and automotive markets.
-
product
AC/DC Withstanding Voltage& Resistance Tester
TH9201S
Changzhou Tonghui Electronic Co., Ltd.
TH9201S AC/DC withstanding voltage & insulation tester is a kind of Hipot Tester. Due to simple and compact structure, mature technique, brand new structure and operating interface, the operation becomes more convenient, and more practical functions are included as well. TH9201S can be widely applied in transformer, device, component especially for winding safety inspection.
-
product
Primary Current Injection Test Set
T 2000
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
product
Digital High Frequency Surge Testers
C Model
These Digital High Frequency Surge Testers are the ultimate in ruggedness & durability. Fourteen / sixteen gauge steel construction and mobility on 6" heavy duty rubber wheels makes it a favorite for use in harsh industrial environments. The performance of PJ's exclusive/unique High Frequency Technology is capable of testing the integrity of any turn-to-turn insulation, including low inductance windings.
-
product
Cable Electric Resistance Tester
MR 270 C-A
The MR270C-A is specially designed for electric resistance measurements in cable industry applications and inductive loads (transformers, motors). It is perfectly fit both for measuring the meter resistance in connection with a corresponding resistance measurement holding device or for final acceptance control of power cable reels. In the case of cable reels, which often have a cable length of several kilometers, both the compensation of the inductive component and the ability to perform measurements in the presence of high noise levels are important. This also applies to the winding resistance of transformers and motors.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Static & Lighting Chokes
Lighting chokes are used to pass tower lighting voltages across the base insulator of a series-fed tower without appreciably altering the tower impedance. LBA TC-300 general purpose tower lighting chokes are provided for three wire 110/220 VAC circuits. Maximum current is 25 amps. These chokes are rated for peak base voltages to 10,000 volts, and present a typical reactance of +j5000 ohms at 530 kHz. Bypass capacitors are provided on each winding.
-
product
3-Axis Ultrasonic Anemometer
HD2003
HD2003 is a 3-axis static anemometer for measuring wind speed and direction, U-V-W cartesian components of speed, wind gust, sound speed, sonic temperature, air temperature, relative humidity and barometric pressure.
-
product
Winding Resistance Meter
TRM 25
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
product
Ruggedized Ethernet Data Acquisition Systems
Series 7000
The Series 7000 Ruggedized Ethernet DAS brings new capabilities and levels of performance to transducer data acquisition. The ruggedized system is designed for installation in wind tunnels, engine test stands and other facilities where it is desired to locate the DAS on or near the test article, reducing installation and cable costs while improving signal quality and reliability. Each unit is a network appliance which conditions, amplifies and digitizes outputs from transducers. Multiple units are easily combined and distributable for larger installations. Real-time temperature Compensation of gain offset and Excitation Voltage, quality signal conditioning with high gain and a 24-Bit A/D per channel provide a high accuracy and high resolution DAS that will perform across a wide operating range.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Surge Tester
They are designed to detect quality defects in the insulation between winding turns, ensuring the reliability and performance of electrical components.
-
product
Tide Gauge
TideMaster
The Tidemaster is the cost-effective way to accurately record water height, with the added option of gathering meteorological data using its ultrasonic wind speed and direction sensor.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Current Transformer Testers
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
product
Core Fusion Splicer with Dual Observation
STC-OFS701H
Shanghai Stone Communication tech Co., Ltd
The smallest Core to core fusion splicer with dual observation Weight 1.2kg only 3.5 inch TFT color LCD monitor with X & Y view simultaneously Fiber core can be displayed clearly with large magnification Alignment mode: Core, cladding and manual alignment 9 seconds splice time and 30 seconds heat time Friendly operation interface and smart menu Operation with Max wind velocity of 15m/s Operation with max 5000m above sea level Typical 120 cycles with battery
-
product
Core Loss Testers
S30 and S30S Series
Stacks built with punched laminations can have a lot of quality issues. Even though the lamination material is tested in sheet format before any process, that alone is not sufficient to guarantee good quality stators. Wear and tear of the punch, bad welding, bad insulating coating in annealing add to the magnetic losses in the stator. It is always advisable to test the stator core in it's final format before winding to ensure good quality throughout the production batch.
-
product
Impulse Winding Tester
TH2883S8-5
Changzhou Tonghui Electronic Co., Ltd.
TH2883 series products are newly developed impulse winding testers by Tonghui. This product line makes Tonghui as the first provider of impulse winding tester from low voltage of 30V to high voltage of 10kV, single channel to multichannel (Max.:8 channels) in this industry. The instrument adopts popular 32 bit CPU and high density SMD technology, 65k color 7-inch TFT wide display screen, bringing ease for your eyes and convenience to your operation. The impulse voltage of100V~5000V, maximum 8 channel sweep test, maximum 20 test procedures, sampling rate of 200Msps, memory depth of 6k bytes makes your test accurately.The usage of standard sample average, application of demagnetized impulse, high bandwidth analog acquisition circuit, technology of high-fidelity corona extraction as well as the opening of non-destructive test reflect the design philosophy “customer-oriented, share the future technology with you” of Tonghui.
-
product
Electrical Safety Test Solutions
Hipot Analyzers with 500VA output rating can be used to test and analyze the withstand voltage of high power and leakage current for the products like motor stators and rotors with high parasitic capacitance. Corona detection can be used for turn-to-turn or turn-to-ground test to avoid winding insulation failure from corona discharge.
-
product
Full 4-Quadrant Grid Simulator
TC.ACS
The increasing number of alternative power sources like solar, wind driven or biological energy systems call for consistent and well demanding regulations for energy feed into the utility grid. Manufacturers of such systems have to test and to prove the compliance of their equipment. Grid simulators form an electronic equivalent circuit for the grid, but allow to vary all relevant parameters in order to test the behaviour and response of the equipment under test.
-
product
Certified Solutions
Advantech has several certified products for the railway automation or power & energy automation, such as IEEE 1613 controllers, EN50155 switches and IEC 61850 substation controllers. All these certified solutions are for the transportation or power & energy industries. The certified products are verified by individual third party organizations to help your system work more reliably in substation automation applications. EN50155 certified solutions, including EN50155 switches, are designed for passenger information system, the IEC 61850-3 and IEEE 1613 certified solutions, such as IEC 61850 substation controller and IEEE 1613 controller, are suitable for substation automation and wind power grid automation, the Det Norske Veritas (DNV) certified solutions which are integrated with ECDIS, are ideal for navigation applications. The certified solutions Advantech offers means engineers can create reliable and safe working environments.
-
product
Armature Tester
Qingdao AIP Intelligent Instruments Co., Ltd
This tester is suitable for online or offline detection of various armature electrical properties, such as power tool motors, garden tools, vacuum cleaner motors, small household appliance motors, automobile motors, fitness equipment motors, permanent magnet micro-motors, etc. The tooling of the tester meets the requirements of arbitrary placement of the armature, and can automatically and accurately sort/track faulty solder joints; the equipment startup methods include buttons, remote control, and sliding cover; it meets the armature test of special processes such as double insulation, and automatically identifies solder joints, winding short circuit/open circuit , winding errors, poor welding and other problems; the tester can also automatically count the number of tests, the number of defectives and other data, which is convenient for quality management analysis.The tester test items mainly include:bar-to-bar resistance, diagonal resistance, welding resistance, insulation resistance, ac hi-pot, surge.
-
product
STDETransformer Demagnetizer
STDE
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
product
Transformer Winding Resistance Meters
TWA Advanced Series
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.