Wind
See Also: Wind Tunnels, Anemometers, Wind Turbine, Wind Speed, Turbulence
-
Product
400/5A CHEAP SPLIT CORE CAST RESIN CURRENT TRANSFORMER
LZCK310-10
-
Beijing GFUVE Electronics Co.,Ltd.
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
-
Product
Dynamic UPS
ROTOBLOC® RBT SERIES 400 - 2000 kVA
-
The RBT system consists of a standard synchronous generator with no special windings and a simple steel flywheel. The low speed shaft extends bearing life and reduces maintenance. The ROTABLOC® machine is very robust as critical functions do not use fragile components such as power electronics, power capacitors, electro-chemical batteries, active magnetic bearings, electro-mechanical or mechanical friction clutches.
-
Product
AUTOMATIC WINDING TEST SYSTEM
VE9036SU
-
6 CHANNEL Microprocessor based Automatic Test System for Automobile Coils, Magnetos, Alternator, Motor Winding. Can Test : Impulse Winding Tester (IW), AC/DC HiPot, Insulation Resistance (IR), Inductance (L), DC Resistance (DCR)
-
Product
TRANSFORMER WINDING RESISTANCE METER
-
International Biological Laboratories
This Test set is suitable to measure winding resistance of transformers, single or 3-phase, star or delta connected upto several MVA.Two independent displays read the resistance of both primary & secondary windings simultaneously. However, primary or secondary winding can also be measured separately.
-
Product
Automatic Production Tester for Electric Motor Stators
MTC 3
-
The fully automatic MTC3 stator testers test your windings reliably and quickly for possible insulation faults via our patented surge voltage test.After connecting the test object completely the test is performed with an automatic switching of the connections and the test methods. The MTC3 evaluates each test step. At the end of the complete test process it provides a clear and reproducible GO or NO GO-statement.
-
Product
Millohm & LCR
-
Help prevent failures in motor windings, generators and transformers with a quick and easy resistance test using an Amprobe milliohm meter. To efficiently inspect and verify electronic components for quality control, choose an Amprobe LCR tester.
-
Product
Air Quality Monitoring System
-
A system that measures metrological parameters such as wind speed, wind direction, rainfall, radiation, temperature, barometric pressure and ambient parameters.
-
Product
Wound Component EST Analyzer
19036
-
Chroma Systems Solutions, Inc.
The industry’s first Wound Component Electrical Safety Test (EST) Analyzer that combines impulse winding, AC/DC hipot, insulation resistance and DC resistance test measurement functions. Chroma’s 19036 Wound Component EST Analyzer has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement with a maximum output of up to 40 channels. Capable of outputting and measuring AC100mA/DC 20mA, Chroma’s 19036 is suitable for testing to high power motor standards such as UL 1004-1.
-
Product
Vehicle Test Chambers
-
Our dynamometer chambers feature dependable mechanical refrigeration, superior air flow, and expansive control systems. Our dynamometer drive-in vehicle test chambers are designed to integrate directly with a dynamometer system, while simultaneously exposing vehicles to a wide variety of environmental conditions including temperature and/or humidity, rain, wind, and more. Our control systems allow for precise temperature and humidity testing while meeting your exact specifications.
-
Product
Turns Ratio Testing
-
The transformer turns ratio test, or TTR test, confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Megger’s range of TTR testers are robust to withstand the harsh conditions that some transformer testing in. The range includes varying features to simplify and speed up testing as well as 3 phase TTR testers and PT and CT TTR testers.
-
Product
Wave Buoy
MOTUS
-
The MOTUS (movement in Latin) Wave Buoy is a perfect solution for collecting environmental data in coastal areas.Collect reliable environmental data with MOTUS Wave Data Buoy.The MOTUS (movement in Latin) Buoy is a perfect solution for collecting environmental data in coastal areas for all-year deployments. The platform used for collecting data is a robust buoy which has proven to be an excellent platform for providing high accuracy and reliable meteorological and oceanographic data. The wave buoy can effectively combine various Hydrological and Meteorological parameters. Basic parameters such as wind, waves, and currents can easily be expanded to include sensor packages with different water quality sensors. Data is controlled and synchronized by the data management systems that Xylem Analytics offers, which also controls and powers real-time communication. This provides a low-power efficient system offering long-term deployment capabilities.The MOTUS Wave Buoys combine our ultra-low power and field-proven solutions from developing oceanographic and water quality sensors. We have 60 years of experience operating in the industry, providing you with an optimal platform based on the buoy, a rugged, lightweight polyethylene buoy deployed in more than 40 countries all over the world. By selecting Xylem as your partner in your projects, you are on track for the lowest overall cost of ownership and a versatile platform that can be tailored to your needs. The MOTUS Buoy is developed for both scientific and commercial use.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Fiber Optics
-
The Neoptix product line includes fiber optic temperature sensors for transformer windings temperature monitoring and for laboratory, industrial, and medical applications.
-
Product
Transformer Turn Ratio Meter
-
A specialized, highly accurate diagnostic instrument used to measure the ratio of primary to secondary winding turns in transformers.
-
Product
Low Voltage Single Phase
600V Class
-
These transformers are encased in a thermoplastic case with the core and windings encapsulated in resin. They are designed for line-to-line operation but may also be used in line-to-neutral or line-to-ground configuration at 58% of rated voltage. It is recommended that a 1.6 Amp fuse be used in the secondary to protect the transformer.
-
Product
Anemometers
-
Sper Scientific offers a wide selection of anemometers for directly measuring wind and air velocity. They will tell you all you need to know about the speed of the wind, the temperature, even humidity and heat stress information. The extraordinary range of uses that our meters provide have made them required equipment in a wide range of professional settings. Firefighters, farmers, HVAC technicians and military personnel all over the world use these meters to gather accurate, real-time data.
-
Product
Thermal Shock Test Chamber (3 Zone)
-
Guangdong Test EQ Equipment co., Ltd.
- Divided into a high-temperature zone, low-temperature zone, and test zone. The test product is placed in the test zone, and the temperature from the high-temperature zone or low-temperature zone is applied to the test zone for thermal shock. The test product remains static during the test.- Equiped with a touch-screen control interface for easy operation.- Temperature is transferred to the test zone using a wind route switching method to perform thermal shock testing.- The maximum duration of high-temperature or low-temperature shock can reach 999 hours, and the maximum cycle period can reach 9999 cycles.- The system can operate in automatic cycle mode or manually select specific shocks. It can be set to perform two-zone or three-zone shocks, as well as cold-to-hot or hot-to-cold transitions.- The cooling system utilizes a dual refrigeration system, providing fast cooling. Water cooling is employed as the cooling method.- Testing can be performed at room temperature.
-
Product
Ambient Air Quality Monitoring System
AQMS
-
AQMS, the doctor for "Human Health"An Air Quality Monitoring Station (AQMS) is a system that measures metrological parameters such as wind speed, wind direction, rainfall, radiation, temperature, barometric pressure and ambient parameters. The AQMS also integrates a series of ambient analyzers to monitor the concentration of air pollutants (such as SO2, NOx, CO, O3, THC, PM, etc.), continuously. HORIBA also provides mobile monitoring stations that can be used to monitor ambient conditions at multiple sites.
-
Product
High-performance multifunctional AC Power Supplies (CV/CF)
PCR-LE Series
-
The PCR-LE Series is a new line of advanced multifunctional AC power supply that has been developed from our PCR-L/LA Series (linear amplifier type). The PCR-LE Series provides high reliability and can be applied to various applications, by taking advantage of the features that can control broadband waveform freely. Moreover, the PCR-LE Series can be configured as a core device of a test system combined with E-loads and Power Analyzers for “Grid Connection Testing” in regard to dispersed power generation, such as Solar Power, Wind Power, Fuel Cell, and Gas Engine referred to as “New Energy Field”. With various options, the low frequency immunity test and various power enviroment tests are supported. The options for parallel operation and three-phase operation enable you to expand a single-phase system up-to 27kVA, single-phase three wires up-to 54kVA, and a three-phase system up to 81kVA. The system can be applied to a large-scale EMC site for testing of industrial high-capacity air conditioners.
-
Product
Log Periodic Dipole Array
ALP620
-
Skeletal remote antenna for decreased wind loading. The ALP Series antennas are a Log Periodic Dipole Array (LPDA) design that provides a useful directional pattern over a broad frequency bandwidth.
-
Product
2 Axis Ultrasonic Anemometer
HD52.3D… Series
-
Measurement of wind speed and wind direction. It can be combined with RH, temperature, pressure and radiation.
-
Product
Transformer Winding Resistance Meter
10A
-
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
Product
Anemometers
-
An anemometer measures wind speed. Indoors, an anemometer measures air speed, air velocity or air flow. The air flow rate in buildings is often measured in cubic feet per minute (CFM) using anemometers to assess the performance of heating, ventilation and air conditioning (HVAC) systems and equipment.PCE Instruments (PCE) offers a variety of anemometer products to meet the air flow and wind speed measurement needs of professionals in industries such as HVAC, construction, marine and wind power and energy, including hot-wire anemometers, thermo anemometers, pitot tube anemometers, cup anemometers, rotating vane anemometers and impeller anemometers with capture hoods. Plus, hobbyists such as boating, sailing and water sports enthusiasts utilize PCE's accurate and affordable digital handheld anemometer and portable mini anemometer product offerings to evaluate outdoor wind conditions. For meteorological measurements, please see PCE's weather station products.
-
Product
Winding Resistance Tester
JYR20S/10S
-
DC winding resistance testing is regarded as another essential routine screening tool. It indicates problems such as loose, defective or incorrect connections, which cause enough transformer failures each year to be regarded as a failure category of its own.
-
Product
Surge Testers
MTC 2
-
Advanced automatic high precision electrical winding testers for testing products like alternators, stators, transformers, armatures and motors. Available as static or portable units from 6-50 kV.
-
Product
Robust DIN-rail Fanless Embedded System With Intel® Atom™ Processor E3815 As An Intel® IoT Gateway Solution
ICO300-MI
-
The ICO300-MI based on Intel® Gateway Technology has been upgraded with Wind River Intelligent Device Platform XT v3.1. The reliable din-rail embedded IoT gateway platform utilizes the low power Intel® Atom™ processor E3815 and supports DDR3L system memory maximum up to 4GB, delivering high performance and low power consumption. It provides enterprise-grade security and intelligent manageability, yet simplifies the development process and gateway deployment for IoT applications. The intelligent ICO300-MI is a perfect solution for industrial IoT applications such as smart energy, smart factory automation, facility monitoring systems and more.
-
Product
Automatic Three Phase Transformer Ratio Meter
ATRM PLUS
-
*Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.
-
Product
Smart Anemometer
-
Together, they show the latest wind data directly on your smartphone. Using cutting-edge ultrasound technology, the Anemometer reliably measures wind speed and direction in real time.
-
Product
DC Bias Current Power Supply
TH1775
-
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
Product
Transformer Winding Resistance Meters
RMO TW Series
-
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.





























