Time Standards
An absolute criterion for measuring time.
See Also: Time, Time Reference, Timers, Time Interval, GPS Time, Time Code, Time Domain, Timing, Hydrogen Masers, Atomic Clocks
-
product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30U
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4B
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Standard - 5.00 (142.00) - 8.30 (235.00) Feed Through Probe
P3325-0
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 645Overall Length (mm): 16.38
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25UN-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1J-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard Voltage 9 Pin D-Type Cables - Connector to Unterminated for Pickering
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1C1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
PCIe Digital Waveform Acquisition with Programmable Threshold - 720 MBit/s Internal Sampling Rate Timing, 700 MBit/s External State Clock
M4I.7730-X8
The M4i.77xx-x8 series digital waveform acquisition (logic-analyzer) cards include versions with 32 synchronous channels, either single-ended with programmable threshold levels or differential. The large onboard memory can be segmented to record different waveform sequences. While the M4i.77xx cards have been designed using the latest technology they are still software compatible with the drivers from earlier Spectrum digital acquisition cards. Therefore existing customers can use the same software they developed for a 10 year old 60 MS/s digital input card also for an M4i.77xx series 720 MS/s logic analyzer.
-
product
IEC60335 Standard Electrical Temperature Tester
CX-w15
Shenzhen Chuangxin Instruments Co., Ltd.
Standard Test corner/room conform to IEC60335-1:2004. and GB4706.1-2005. can be used to the temperaturetest of all kinds of electronic products supply, in conformity with the standards requirement of the environmental conditions.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.81 (23.00) - 4.50 (128.00) Battery Probe
CP-059-026
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.00Mechanical Life (no of cyles): 100,000Overall Length (mil): 221Overall Length (mm): 5.61
-
product
High Frequency Standard Capacitor
GenRad 1403 Series
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
product
Standard Voltage 37-Pin D-Type Connector & Cable Accessories
The Standard Voltage 37-Pin D-Type connector is used on PXI switching products to provide a medium density connector solution.Connection solutions for modules with High Voltage Rating D-Type connectors are also available.
-
product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H150-1
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
Open Standard Module (OSM)
Advantech's OSM, the SGeT standard for PCB soldering design with NXP platforms, boasts an ultra-low power, miniaturized design for AIoT endpoints.
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I40-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1C
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Time Domain Reflectometer
STEP TDRS
Cable Measurements: Distance, Fault Types, Distance to Faults, Impedance Readings, and Loop Resistance.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25H-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Single Or Dual Stream MIL-STD-1553A/BTest And Simulation Module For Standard Ethernet
ANET1553-x
The ANET1553-x is a member of AIM’s new line of Ethernet based modules for analysing, simulating, monitoring and testing MIL-STD-1553A/B databuses. For wireless applications, an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
product
Cable Fault Locator With Time Domain (Intelligent Bridge)
GT00ZD00ZY
GAOTek Cable Fault Locator with Time Domain has a reflectometer to locate faults in metallic cables and Intelligent bridge for tesing the broken line
-
product
STANAG3910 Electrica lTest And Simulation Modulefor Standard Ethernet
ANET3910-EN
STANAG3910 Electrical Test and Simulation module for Standard Ethernet. The ANET embedded Linux operating system gives the unique capability to run the optional PBA.pro Engine right in the box.Another option is the ANET-ADK onboard software development kit where users create run-time applications to execute right in the box. For wireless applications, an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard VXI Module Shield Kits With Address Switch Opening
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Clamshell design fits C-size modules with 96-pin connectors.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Address switch opening on component side shield.* Complimentary layout support includes PCB design template and CAD layout files.
-
product
Time Code Processors
TSync
Safran Federal Systems' TSync time code processors are complete, synchronized timecode reader/generator boards and peripheral slot cards, offering flexibility and easy integration for mission-critical embedded applications.
-
product
Standard Gain Horn Pyramidal Horn Antenna
Elva’s SGPH series of standard gain horn antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
product
Inductance Standard
1482 Series
The GenRad 1482 Standard Inductors are the standard of choice in metrology labs. Used today by national metrology institutes and primary standards bodies around the world, these inductors have no peer or equivlent.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1J
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64





























