Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
“Two-Pressure” Humidity Generation System
9500
The Model 9500 Humidity Generator is a system capable of producing known humidity values using the fundamental, NIST proven, "two-pressure" principle. The 9500 is capable of continuously supplying an accurately known relative humidity, dew point, frost point, parts per million, or other calculated values for instrument calibration and evaluation as well as precision environmental testing.
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Coaxial Termination, DC to 50 GHz
85138B
The Keysight 85138B is a precision, low-reflection dc to 50 GHz load for terminating a 50-ohm coaxial system in its characteristic impedance. It is intended for use as a calibration standard. The Keysight 85138B has a 2.4 mm female connector.
-
product
Peel Force Tester
PT-55
V-TEK Peel Force Testers are built to test, confirm, and record proper sealing strength of cover tape to carrier tape. This ensures parts are secure and protected, yet will release at the designated force. The PT-55 Peel Force Tester incorporates new technology and performance features to make set up easy, maintenance minimal, and calibration accurate. The lightweight design can accommodate 8-120mm tape widths and operates at peel speeds of 120mm/min or 300mm/min.
-
product
HIPOT Insulation Testers
Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.
-
product
Calibrators
TES Electrical Electronic Corp.
Unique mapping function let you calibrate temperature. iCal is a multifunction calibrator and an arbitrary function generator.
-
product
Product Range
ProtIR 204M
The 204M is a transportable CEM based on FTIR technology. Using the 204M for measurements of waste incineration and combustion plant process is as simple using an FTIR can be. With pre-loaded calibration methods for 28 gas species, automatic nitrogen purging, in-built pressure and temperature alarms, analogue and digital I/O it is a complete site-ready back up CEM.
-
product
Electricity Meter Test Equipment
The Reference Standard RS is precision standard meter in single- and three-phase version for electrical power and energy measurement. It is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any true or artificial mode of operation in three phase system and is capable to evaluate individual quantities in any phase
-
product
Application worx
Is a chemometric software package that is designed for calibration development in the field of NIR spectroscopy. AWX is used to predict chemical characteristics of the Near Infra Red spectrum of a sample.
-
product
Data Logger for Temperature and Humidity
DSR-TH
Built-in compact high precision temperature and humidity sensors Selectable USB, RS232 / 485, LAN, wireless communication interfaces High definition LCD with wider viewing angles and redundant operation temperature Support on-line linear and nonlinear calibration Suitable for pharmaceutical, electronic production, biochemistry laboratory, museum management and other applications
-
product
Current Probe Calibrator
KSZ
PMK Mess- und Kommunikationstechnik GmbH
Since Current Probes are often exposed to hard working conditions, a performance check is recommendedbefore every use. These Current Probe Calibrators generate square wave pulses from 0.05 A to 1000 A with an accuracy better 1%. They qualify for calibration and adjustment of Current Probes.
-
product
Precision Capacitance Meter
TH2638
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
product
Blackbody System
IR-518/301
Infrared Systems Development Corp.
The IR-518 Radiation Source provides an accurate, stable source of infrared radiation of known flux and spectral distribution. It can be used as a standard radiation source for the calibration of other laboratory sources, detectors, or other infrared devices requiring calibration against a standard.
-
product
Gauges & Calibrators
Ralston Instruments' gauges and calibrators are born from decades of experience working with technicians, project managers and facilities teams responsible for maintaining metrology instruments.
-
product
Scalar Mixer/Converter Measurements
S93082B
The S93082B scalar mixer/converter measurements enables the highest accuracy for scalar conversion–loss/gain measurements with a simple set-up and calibration
-
product
Insulation & Multifunction Tester (LCD Display)
4153 IN
Standard Electric Works Co., Ltd
Microprocessor-controlled. Measures Insulation Resistance, voltage (AC-DC) measurements with automatic hold facility, diode, ohm, and continuity with a short circuit current of minimum 220mA. Auto-off function. Energy conservation feature. Ener-Save™ limit the test duration to about 10 Seconds. Quick Test and EnerSave™ are unique features. Both saves energy. No moving parts. All calibration are saved internally in a non volatile memory. Easy calibration at any facility around the world. Operates with rechargeable batteries, alkaline or low cost general purpose batteries. Low cost maintenance, calibration, and ownership. Complies to all the latest regulations, including UK.
-
product
Digital (1kV up) H.V. Insulation Tester
6210A IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
Standard Electric Works Co., Ltd
Microprocessor-controlled. Four insulation test voltages. Insulation resistance; auto ranging on all ranges. Bargraph indicates test voltage; rise and decay can be observed during tests. Visual and audible warning if external voltage is present. Fully protected: crow bar. Carry case. EEPROM calibration.
-
product
NFC Physical Layer Test System
IQnfc+
LitePoint provides turn-key software that facilitates test coil calibration, executes test plan and provides detailed waveform analysis and flexible APIs to customize test flow in the labs.
-
product
Refractometer Calibration Oils
Calibration Oils are one of the most commonly used materials for calibrating refractometers as they have good traceability, particularly to NIST. Having a high temperature co-efficient, Calibration Oils are best used where strict temperature control is adopted either by Peltier or external waterbath between 10 and 75 °C as well as with refractometers operating at ambient by making use of supplied tables or an RI/°C Temperature Calculator as long as the prism temperature is reliably known.
-
product
Reference Magnets
Series MT
The reasonably priced WUNTRONIC standard reference magnets offer the possibility in a simple way of being able to calibrate or to check magnet measuring instruments like Gauss Meter/Tesla Meter with the respectively accompanying probes in a defined magnetic field.
-
product
4-in-1 OSLT Calibration Kit, DC to 50 GHz, 2.4 mm (m)
CK564A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Intelligent Pressure Calibrator
Huaxin Instrument (Beijing) Co., Ltd
Here at Huaxin, we offer a selection of HS602 and HX601B intelligent pressure calibrators. They are high pressure, single range digital pressure calibrators with HART communication capability. Composed of high precision measurement chip, 24V DC power supply, battery charging protection circuit, HART communication module and intelligent digital pressure module, these two pressure calibrators provide a pressure calibration solution for gauges, transmitters, and switches over a wide pressure range.
-
product
Handheld Economic Process Calibrator
VA701
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This Multifunction calibrator combined voltage. current .resistance .thermocouple temperature .RTD in one device.
-
product
Loudspeaker Testing
TTC
The weakest link in your measurement chain is your chamber, the new TTC chambers solve these problems...*Anechoic chambers have massive footprints:The TTC gives you equal or better results with a compact footprint*Achieving repeatable measurements is difficult in an anechoic chamber:The TTC guarantees the microphone and loudspeaker positions*Anechoic chamber accuracy suffers at low frequencies:The TTC is capable of measuring below 20 Hz*Results are not transferable between most test chambers:The TTC meets international standards IEC 60268-21:2018 & IEC 60268-22:2020*Most chambers are difficult to calibrate and awkward to use:The TTC is calibrated and is ready to interface to your microphone and analyzer
-
product
Test Equipment Calibration Services
Custom Calibration Solutions, LLC
Custom Calibration Solutions assists customers in meeting or exceeding individual business goals by striking the ultimate balance between quality objectives and cost. We can optimize any existing test equipment calibration program by combining the use of our proprietary procedures in conjunction with the most appropriate standards for each calibration task.
-
product
Primary Current Injection Sets
Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.
-
product
NI-9215, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783739-01
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
product
Waveguide Cassette
Waveguide cassettes provide easy way for the network analyzer calibration and material properties as dielectric permittivity or (and) magnetic permeability measurements. By changing insertion sections, it is possible to calibrate "Short" and "Thru". Optional cassettes with quarter wave "short" inserters are available. Using this waveguide cassette, it is possible to do vector network analyzer calibration or additional scalar network analyzer calibration. Insertable sample holders supports two measurement methods: the rod in the centre of the waveguide and filled waveguide cross-section.