A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
Categories
-
product
Pressure Transducers with Serial(485) Interface
P855
The Validyne model P855 is a digitally compensated differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments.
-
product
Vehicle Data Acquisition System
VDAS
The Validyne VDAS integrates all your data acquisition requirements for vehicle testing into one compact, rugged system. Up to 300 vehicle sensor channels can be accepted by the VDAS so that time consuming change-outs of instrumentation packages can be minimized. The same VDAS is easily shared by several test groups; system configurations can be saved and re-loaded as needed.
-
product
Low Range Low Cost OEM Differential Pressure Transducer
P17
The P17 OEM Low Range Low Cost pressure transducer features high sensitivity to very low pressures with full scales available down to 0.1 In H2O. Output signal is 5 Vdc and power can be +5 to +28 Vdc. Zero and Span adjustments are included. The P17 has a robust steel sensor construction.
-
product
Pressure Transducers with CAN Bus Interface
P66
The Validyne model P66 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via CAN Bus provides remote zero and span adjustment as well as digital pressure readings in engineering units or pressure counts.
-
product
Multi-Channel Carrier Demodulator
CD280
The CD280 Carrier Demodulator is a complete multi channel system in a small package which houses a plug-in power supply and 4 carrier demodulator circuit boards. The power supply provides regulated 5 Vac 5 kHz carrier power for Variable Reluctance and LVDT transducers , and the carrier demodulators demodulate and amplify the input signals to a 10 Vdc full-scale output. Zero and span adjustments are available for each channel. The system operates from 115 Vac, 50 to 400 Hz, line power.
-
product
Single-Channel DC Powered Carrier Demodulator
CD16
The CD16 Miniature Carrier Demodulator is designed to deliver a 0 to 5 Vdc output from a variable reluctance transducer and operate from unregulated 9 to 55 Vdc power. A square wave excitation of 5 kHz is furnished to the transducer and the solid state integrated circuit amplifier and demodulator converts the transducer signal to an analog dc output. Zero and Span adjustments are made through access holes in the case.
-
product
Digital Display for the Transducers and Transmitters
PS57
The PS57 is a combination power supply and 4 1/2 digit LED display for the P55/P855 family of pressure transducers and transmitters. The PS57 accepts 110 VAC power and provides the required 24 Vdc excitation for the transducer. The transducer signal is received and displayed directly in engineering units with bright 0.56 high red LEDs. The user can re-scale the display and set the decimal point by configuring internal jumpers. The analog output of the transducer, 5 Vdc or 4-20 mA, is available on rear-panel terminals.
-
product
Draft Range Trasmitter
DR800
The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.
-
product
Wet-Wet Differential Pressure Sensor
DP303
The DP303 features "take-apart" construction enabling the user to easily disassemble the unit for cleaning or to change full scale range by exchanging the sensing diaphragm. As noted from the Pressure Range/Diaphragm Selection Chart on the reverse side of this Data Sheet, a family of interchangeable diaphragms are available to cover virtually any full scale pressure range from 0.08 psid full scale to 5,000 psid full scale-all rated for operation at 5,000 psig line pressure!
-
product
Portable Carrier Demodulator with Digital Display
CD379
The CD379 is a portable, completely self contained digital transducer indicator. In addition to the front panel liquid crystal digital display, the unit also provides a 2 Vdc analog output suitable for recording, remote display or control purposes. The unit is for use with all variable reluctance transducers and features solid state electronics, 3 1/2 digit liquid crystal display and battery pack with six 1.5V penlight cells for truly portable operation. The unit can also be powered from an external DC power supply or AC battery eliminator (converter) module.
-
product
Very Low Pressure Variable Reluctance Sensor
DP103
The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.