Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
-
product
Easy Sense Software
Easy Sense 2100 is available for use with the UPC2100. Easy Sense 225x is used with the Universal Data Acquisition System(UDAS) or the USB2251. The Software includes a GUI configuration utility that allows the user to set sensor type, gain range, channel, and all other input parameters. The configuration can be saved to non-volatile memory on the card so that the UP2100 or the UDAS can be used in embedded applications.
-
product
Vehicle Pressure Acquisition System
VPAS
The Vehicle Pressure Acquisition System (VPAS) is designed to record and display up to 8 or 16 low pressure measurement points for the investigation of vehicle pressures within the passenger cabin, in HVAC ducting or with respect to the exterior of the vehicle. Validyne DP103 pressure sensors can be ordered with full scale ranges as low as 0.1 in H20 and up to 55 in H20.
-
product
Portable Digital Manometer
PS309
Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.
-
product
Variable Reluctance Pressure Sensor Capable of Range Changes
DP15
An easy-to-replace pressure-sensing diaphragm maximizes the system's functionality by making pressure measurements from 2.22" H2O to 3200 psi in one compact unit. Rugged and reliable, the DP15 pressure sensor provides superior accuracy for measuring low-pressure liquids and gasses, while it withstands the abuse of field and laboratory testing. The ability to change full scale ranges make the DP15 a very cost effective solution for applications that need different pressure ranges or university labs.
-
product
Speed Pick-up
SU63
The Validyne SU63 is an AC inductive speed pick-up used for RPM measurement on high-speed rotating equipment. The SU63 is a tightly-wound coil with a laminated core that can be conveniently mounted on rotating equipment so that the magnetic field of a magnetized nut or part passes through the coil windings. The moving magnetic field produces a voltage within the coil proportional to its rate of change and the strength of the permanent magnetized part. The frequency of this inductive voltage spike is fed into an oscilloscope or counter to determine RPM.
-
product
Multi-Channel Carrier Demodulator
CD280
The CD280 Carrier Demodulator is a complete multi channel system in a small package which houses a plug-in power supply and 4 carrier demodulator circuit boards. The power supply provides regulated 5 Vac 5 kHz carrier power for Variable Reluctance and LVDT transducers , and the carrier demodulators demodulate and amplify the input signals to a 10 Vdc full-scale output. Zero and span adjustments are available for each channel. The system operates from 115 Vac, 50 to 400 Hz, line power.
-
product
Low Range Low Cost OEM Differential Pressure Transducer
P17
The P17 OEM Low Range Low Cost pressure transducer features high sensitivity to very low pressures with full scales available down to 0.1 In H2O. Output signal is 5 Vdc and power can be +5 to +28 Vdc. Zero and Span adjustments are included. The P17 has a robust steel sensor construction.
-
product
HVAC Pressure Transmitter
DP850/851
The DP850/851 transmitters are designed for low pressure measurement in HVAC applications. The DP850 is available in full scale pressure ranges as low as 0.25 inH2O and the DP851 can be ranged to 0.025 inH2O full scale. Both models are available in 4-20 mA or 0 to +5 Vdc signal output options.
-
product
Draft Range Trasmitter
DR800
The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.
-
product
Single-Channel USB Carrier Demodulator
CD17
The Validyne model CD17 is a USB-powered carrier demodulator for Validyne variable reluctance pressure sensors such as the DP15, DP45 and DP103. The CD17 allows any Validyne variable reluctance sensor to be used directly with a PC via the USB port. Communication and power via USB interface provides remote zero and span adjustment as well as digital pressure readings in mV/V. Drivers and software for the USB interface are included.
-
product
Universal Data Acquisition System
(UDAS/USB2250)
The Universal Data Acquisition System(UDAS) Sensor Interface provides real world data acquisition for your PC via the USB port. 16 sensor inputs in any mix or combination are accepted by the UDAS. No external signal conditioning is required. The UDAS includes configuration and data acquisition software.
-
product
General Purpose Basic Carrier Demodulator
CD15
The CD15 Sine Wave Carrier Demodulator operates with variable reluctance transducers to provide a DC output signal for dynamics as well as steady state measurements. A 5kHz sine wave excitation is applied to the two inductance ratio arms of the transducer and the resulting output is demodulated and amplified using the latest integrated circuit techniques. The DC output is obtained from an active filter circuit and gives a uniform response from steady state to 1000 Hz. The low impedance sine wave excitation allows operation with the transducer located over 1,000 feet from the CD15.
-
product
Pressure Transducers with CAN Bus Interface
P66
The Validyne model P66 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via CAN Bus provides remote zero and span adjustment as well as digital pressure readings in engineering units or pressure counts.
-
product
Low Pressure Variable Reluctance Sensor
DP45
The Validyne DP45 Very Low Differential Pressure Transducer is designed for extremely low pressure measurement in the order of 1 inch water column. This instrument is used extensively in connection with flow measurements where dynamic response at low flow rates is required. Dynamic line pressure effects are minimized due to the combination of low internal volume, symmetrical construction, and small volumetric displacement inherent in the DP45 design.
-
product
Network Sensor Interface for USB Pressure Transducers
SI314
The Validyne model SI314 is a network interface that connects our model P61 USB pressure Transducer to your smart phone or network web browser. The SI314 supports Ethernet and Wi-Fi connections and will display current pressure readings and transducer status on any web browser or via smart phone. The SI314 also displays the transducer temperature, date of calibration, model and serial numbers and these can be viewed wirelessly or by Ethernet connection. The SI314 makes your P61 accessible from anywhere in the world. Data logging of pressure data is configured via a web browser or smart phone and readings may be stored once per minute to once per hour. A thumb drive or memory card collects the data in comma separated file format(csv) for download to your computer. The data may also be accessed via the network. A graph of the data is also generated on request. A Twitter function allows pressure data to be tweeted from the SI314 at user-defined intervals. The transducer zero and span calibration adjustments are password protected and operated via browser buttons. No potentiometer adjustments are required to calibrate the P61 transducer. Contact our Sales Department for a link to the Demo!