LXinstruments GmbH
The LX instruments GmbH was originally founded in 2006 as a solution provider for all questions relating to instruments and systems of electronic measurement technology. Schwerpunktmäßg our systems are based on the LXI Standard (LAN based Extensions for Instrumentation), an open industry standard.
- +49 (0) 7032 / 895 93-0
- +49 (0) 7032 / 895 93-18
- info@lxinstruments.com
- Rudolf-Diesel-Str. 36
Nufringen, 71154
Germany
-
product
PXI RS232 Interface Galvanic Isolation
PXI‑8432/4 - OTP2-Modul-Nr196
The PXI‑8432/4 module is a high-performance, dielectric-proof interface for high-speed communication with RS-232 devices. The module offers data transfers via the high-speed DMA interface, multithreading and multiprocessor support. NI serial ports appear as standard COM ports for compatibility with programs that use serial communications.
-
product
Multi Channel Optical Fibre Verification
The multi-channel optical fibre test system is used in the development and qualification of single mode optical fibres. The fibres are exposed to environmental influences in a climatic chamber in order to analyse the data on insertion loss and reflection. In addition, the current temperature in the climatic chamber is documented. Insertion loss measurement is performed with the help of an optical power meter, laser sources and optical switches. An Optical Time Domain Reflectometer (OTDR) from Exfo is used for the reflection measurements. The system was designed for the simultaneous characterization of 15 sample fibres and one reference fibre.
-
product
PXI Infrastructure PXI Mainframe / Components
OTP2 module no.182
PXI offers the optimal approach to validation and production testing. You can meet timing, synchronization, and throughput requirements across devices. PXI is a robust PC-based platform for measurement and automation systems, supported by software. PXI combines PCI electrical bus characteristics with CompactPCI's modular Eurocard packaging, and then adds special synchronization buses and important software functions.
-
product
High-Voltage Test Hood with Integrated Hipot
LX-HVE900IS
Large test room with a hood made of sturdy, highly insulating and transparent plastic, which guarantees a clear view of the test item and the signal lamp during the test. The system is operated on the test device. Alternatively, test sequences stored on an integrated computer can be started automatically by closing the hood. The test sequence can be fully followed on the monitor.
-
product
Test for Pacemakers
VXI-based functional test system for testing implantable medical electronic products. The system is equipped with a Virginia Panel Series 90 adapter interface and can be operated standalone as well as on handling systems. Based on the previously developed matrix-based standard architecture, a large number of systems were supplied. The system function can be verified at any time via an automated self-test.
-
product
TSCOE4 Operator Interface Software Module
The TSCOE4 Operator Interface provides a graphical user interface for the operator or the implementer in a production environment. It permits selecting the test sequence and supports parametrization of the test. During the test sequence, the current measurement values are displayed in relation to the relevant limits and the pass/fail evaluations for each individual test. After completion of the test sequence, the global test result is visualized.In addition, there are online statistics available to the user, which show the measurement value distribution within the current batch.The editor which is supplied with the product makes it possible to adapt the user interface language to any new deployment location. Several languages – German, English and Chinese – have already been implemented and are available out of the box.
-
product
PXI Digitizer 16-Bit, 20MSa/s
M9217A
The M9217A PXIe Digitizer is a single slot with 2 isolated input channels that supports up to ±256V and a sample rate of 20MSa/s and 16-bit resolution.
-
product
PXI Interface Cards
PXI is a modular instrument system designed to take advantage of fast data interfaces based on PCI and PCIe bus systems. Due to the large number of different PXI interface cards, the individual test system can be designed for almost all applications.
-
product
Isolated D/A Converter 8 Channel, 250kSa/s
OTP2 module no.187
The PXIe‑4322 is a channel-isolated analog output module with built-in signal conditioning. The module provides accurate, simultaneous dynamic voltage and current outputs. By combining signal conditioning and D/A converters in one device, the PXIe‑4322 isolated analog output module offers smaller dimensions and higher measurement performance. In current mode, the module operates in all four quadrants, allowing current to be drawn and sourced. Thanks to isolation and outputs for higher voltages and currents, the module is particularly suitable for applications in the automotive sector.
-
product
Self Test Application Adapter and Software
OTP2-Modul-Nr210
In order for the system to carry out a self-test, it requires a suitable adapter and software that is tailored to the test system. A self-test is often very helpful and recommended if a system has not been used for a long time or also to see whether the test system is working properly with the specified parameters.
-
product
Pneumatic Subsystem
OTP2-Modul-Nr050
With the pneumatic subsystem, a roller terminal, a maintenance unit, a main vent, a pressure reducer and 8 2/3-way vents are installed in the system. The extension of the module can create new possibilities for your test system.
-
product
High-Voltage Test Hood
LX-HVE600
The bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 640 * 716 * 640mm Usable test space (W * D * H) approx. 450 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "
-
product
TMS Test Management Software
LX TMS
To diagnose and analyze electronic components and devices, various tests are required in development, production and service. Equipped with all the necessary standard functions, the test sequencer developed by LXinstuments meets all criteria for a successful and smooth test process. The test item ( DUT ) is examined under various operating conditions for its properties, function and usability. Typical areas of application can be found where the usual complexity of test sequences has to be processed. The test sequencer is therefore suitable for small and medium-sized systems where special functions of other sequencers are not required. The free, cross-platform, open source developer platform .NET serves as a starting point. The integrated WPF (Windows Presentation Foundation) framework ensures a user-friendly program interface.
-
product
PXI Rackmount Material for Installation
OTP2 module no.180
Materials required for flush mounting the PXI mainframe, also required for mounting the signal routing box
-
product
Isolated Digital I/O 60VDC, 150mA
OTP2 module no.186
The National Instruments PXI-6528, PCI-6528, and PXI-6529 Digital I/O Modules are isolated digital I/O interfaces for PCI and PXI. These modules can use inputs from NI 6528 and PXI 6529 devices to capture the status of sensors, actuators, and logic devices. NI 6528 devices have 24 SSR outputs for switching external devices with input currents up to 150 mA. The NI 6528 and PXI-6529 devices are suitable for a variety of applications, from automotive development and industrial factory automation to aerospace, laboratory research, and biomedical applications due to their high current handling capacity and isolation.