Filter Results By:
Products
Applications
Manufacturers
EMI
unintentional signal interference originating within or outside the system or circuit. Also known as: Electromagnetic Interference
See Also: Interference, Interference Generators, EMI Receivers, RFI, EMC, LISN
- 
			
		
			product Antenna, Ridged GuideEM-6961 | 0.9 GHz – 18 GHz The EM-6961 Double Ridged Guide Antenna is a linearly polarized broadband antenna designed and built specifically for EMI measurements and specification compliance testing. 
- 
			
		
			product EMI ReceiverKH3931 Beijing KeHuan Century EMC Technology Co,.LTD * Detection frequency range: 9KHz-30MHz * Frequency stability: 1X10-6 * Frequency resolution: (9kHz ~ 150kHz): 30Hz; (150kHz ~ 30MHz): 1kHz * Test error: ±2dB * Corresponding characteristics of pulse: in line with national standard GB/T6113.1-1995 * Detection time constant: in line with national standard GB/T6113.1-1995 
- 
			
		
			product Handheld Power & Energy MeterNova 7Z01500 *Compatible with all standard Ophir Thermopile, Pyroelectric & Photodiode sensors.*Single shot energy measurement with thermal sensors.*Optional RS232 computer interface. Works with Ophir's StarCom32 application.*Power and energy logging with graphical display and statistics.*Laser Power Measurement averaging.*Easy to use soft keys, menu driven.*Screen graphics.*Backlight & rechargeable battery.*Analog output.*EMI rejection.*LabVIEW software included. 
- 
			
		
			product 400W to 600W - Single OutputCUS600M Series *400W (600W Peak) Convection Cooled*600W with Forced Air*Medical Certifications (2xMOPP)*Class B Conducted and Radiated EMI*Suitable for Class I and Class II installations*Compact 3 x 5 x 1.46" size 
- 
			
		
			product EMI Test ReceiverESL The R&S®ESL EMI test receiver combines two instruments in one, measuring EMC disturbances in accordance with the relevant standards and also serving as a full-featured spectrum analyzer for diverse lab applications. The combination of very good RF characteristics and all of the important functions needed for fast, precise measurement and evaluation of the EMC of a device under test in accordance with commercial standards is unmatched in this instrument class. 
- 
			
		
			product EMI Check & Resonance Analysis SoftwareEMI Stream At the placement design stage, EMI Stream software examines optimal locations for parts by using actual .dsn files and verifies the effects of the proposed EMI solution. EMI Stream can analyze resonance which occurs between the power and ground planes by analyzing the resonance which occurs and changing the locations of capacitors. 
- 
			
		
			product Real-Time Spectrum AnalyzersRSA 3000 Series The RSA3000 real-time spectrum analyzer with real-time analysis and sweep analysis capabilities, optional EMI measurement application software (EMI), with excellent performance and specifications. Its frequency range is 9kHz to 3.2GHz, and it is available with the tracking source "-TG" model, which can be widely used in enterprise R&D, factory production, education and teaching. 
- 
			
		
			product Near Field Probes 30 MHz up to 3 GHzRF2 set The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. 
- 
			
		
			product EMI TestingIndependent Testing Laboratories ITL offers compliance and qualification testing for virtually any type of electronic product or system. 
- 
			
		
			product PreamplifiersCom-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification. 
- 
			
		
			product Auxiliary DeviceMornsun Guangzhou Science & Technology MORNSUN provides high quality EMC auxiliary devices: EMC filter, surge suppressor, pulse suppressor, EMI filter, etc. 
- 
			
		
			product Emissions Test SystemPC-114 Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing. 
- 
			
		
			product Ground Pro MeterVerifies Critical Grounding Parameters of a FacilityMeasures AC voltage, DC voltage, EMI voltage and AC impedanceProvides Accurate Measurements of Ground Impedance on a Working ToolMeets ANSI/ESD S20.20 requirements for AC impedanceIdentifies Potential EOS Generators 
- 
			
		
			product InvertersAnalytic Systems has been producing Pure Sinewave Inverters since 1994. Originally designed for running navigation computers on commercial and fishing vessels, the line has evolved into a range of models with power outputs from 300 to 3600 watts featuring Digital Signal Processor control. High power MosFet technology creates a low voltage Sinewave that is fed into a compact toroidal step-up transformer to produce a very clean low EMI AC output. Northrup Grumman evaluated inverters from all major manufacturers and chose the IPSi series by Analytic Systems for their Army portable command centers for precisely this reason. 
- 
			
		
			product 300W to 500W - Single OutputCUS500M1 Series *300W (500W Peak) Convection Cooled*500W with Forced Air*Medical Certifications (2xMOPP)*Class B Conducted and Radiated EMI*Suitable for Class I and Class II installations*Compact 3 x 5 x 1.46" size 
- 
			
		
			product Silicon OscillatorsAnalog Devices silicon oscillators are frequency programmable via pin-strapping, or through the resistor connection or serial interface (SPI or I2C). These solid-state clocks are well-suited for general-purpose usage, such as PGAs, ASICS, microprocessors, or UARTS, and they operate from 1 kHz to 170 MHz. Silicon oscillators are also ideal switching regulator clocks as they provide synchronization and EMI reduction (via spread spectrum). 
- 
			
		
			product ITA, G10x, 15 Module, Removable Backshell, Keying Feature410104773 The adaptable G10x ITA integrates a wide variety of I/O options in various module configurations that allow engagement of up to 3,200 signal contacts. The G10x ITA has a removable backshell that also reduces electromagnetic interference. 
- 
			
		
			product 15W to 960W - Single OutputDPP Series *Low Cost*UL 508 Listed*Convection Cooled*Conducted and Radiated EMI, Class B*Input Transient Protection, IEC61000-4*Conforms to EN61000-3-2 (PFC)*Three year warranty 
- 
			
		
			product EMC AccessoriesComplete your EMC test setup with the essential accessories to compliment the test equipment. Whether it is a LISN (or V-Network) to counteract interference from external power sources on conducted emissions from the device under test, probes to locate the near field sources of radiated emissions, receive and transmit antennas, or tripods for holding antennas in place, the Rohde & Schwarz catalog of EMC accessories provides the additional items you need for EMI and EMS measurements, guaranteed 100% suitable for use with Rohde & Schwarz EMC test equipment. 
- 
			
		
			product DIN-rail Embedded SystemAxiomtek’s DIN-rail fanless embedded systems are suitable for intelligent computing and communication solutions in mission critical environments, such as power plant automation and facility monitoring systems. Axiomtek’s DIN-rail fanless embedded PCs are rugged and have passed heavy industrial EMI/EMS (Electro-Magnetic Susceptibility/ Electro-Magnetic Interference) tests for reliability in hazardous environments. 
- 
			
		
			product Power Line EMI AdaptersHow much EMI noise is on your power lines indeed? How to assess the levels of noise and its properties when it is obviously a bad idea to connect your oscilloscope or a spectrum analyzer directly to your power lines?Our EMI interface adapters provide a barrier for high mains voltages but a straight passage for high-frequency signals so that you can connect your sensitive instrument to power lines for analysis and quantification. We offer plug-in and hand-held adapters which can measure both differential ("normal") and common-mode noise. 
- 
			
		
			product AC Power Line EMI FiltersCleanSweep® CleanSweep® filters block EMI on power lines (both common and differential modes) and, uniquely, in ground, from reaching sensitive equipment. They also reduce EMI "backflow" from a "noisy" source that otherwise would end up on your AC power network. 
- 
			
		
			product IC & TransformerMornsun Guangzhou Science & Technology MORNSUN launched the self-designed electronic integrated circuits according to the different product lines, types of the integrated circuit include AC/DC power supply control ICs, DC/DC power supply control ICs, interface ICs, start-up ICs, contactor power saving controller ICs and digital isolator ICs. MORNSUN IC chip can be widely used in industrial equipment, process control, data acquisition system, building automation, smart meter, etc. Adopting MORNSUN's AC/DC transformers and DC/DC transformers, with the use of its control ICs, can achieve wide voltage input flyback power supply design with multiple protection functions and superior EMI performance. We hope that those power transformers along with the integrated circuits & chips electronics can be an ideal fit for your application needs. 
- 
			
		
			product Signal ConditioningSensors that are used to collect the data from the environment often don’t produce signal of characteristics optimal for an analog to digital converter (ADC) to translate to digital data. Additionally, these signals can be subject to electromagnetic interference (EMI) that introduces noise, having a negative impact on the reliability of the data. To make this analog input readable for the processing unit and dependable enough to give the desired quality of data the signal has to undergo a process of signal conditioning. 
- 
			
		
			product EMI ShieldingParker Chomerics electromagnetic interference (EMI) shielding product family spans a wide variety of uses and applications, including an extensive selection of EMI gaskets, shielded windows, shielded honeycomb air vents, cable shielding products, grounding solutions, shielding laminates, and metal foil tapes. It also includes conductive adhesives, coatings, sealants, greases and inks, as well as conductive plastics. 
- 
			
		
			product Faraday CagesLBA's EMFaraCage® faraday cages are EMI and RFI shielding boxes and RF test enclosures that bring convenience to device testing. Faraday cages are ideal for isolating critical systems in high field RF environments or wherever RF ingress or egress must be minimized. Security, production testing, biomedical research and semiconductor testing are only a few of the many areas where EMFaraCage® faraday shielded enclosures are employed. EMFaraCage® faraday cage enclosure systems are fully featured to support a wide variety of test missions. The standard faraday cages include effective power, dataline and RF signal isolation in large test volumes. EMFaraCage® faraday cages are much more affordable than shielded room solutions and offer the convenience of portability. 
- 
			
		
			product EMI ProductsSophisticated design, manufacture and assembly facilities at Oxley UK production center, include a ceramic production capability for discoidal, tubular, and multiway planar array capacitors, CNC machining, electro-plating, prototype model shop, tool room and dedicated test area. 
- 
			
		
			product Magnetic Resonance InstrumentsIntegrated Dynamics Engineering MRI systems represent a significant investment. As magnetic resonance images can be distorted by electromagnetic fields, frequently the location is isolated by passive shielding to somewhat insulate the detectors from image distorting EMI. But for a fraction of the cost of the machine an active EMI compensation can fully protect the image from damaging fields generated by other electrical equipment, passing traffic, elevators or other nearby equipment. 
- 
			
		
			product ITA, i2 MX, EMI Backshell, with Cable Exit (Shell only, does not include front protective cover or modules)410130114 ITA, i2 MX, EMI Backshell, with Cable Exit (Shell only, does not include front protective cover or modules) 
- 
			
		
			product ITA, G40x, 48 Module, Frame Without Protective Cover, Includes EMI Protection410120361 ITA, G40x, 48 Module, Frame Without Protective Cover, Includes EMI Protection.ITA, G40X 410120246 has been obsoleted in favor of 410120361 with EMI shielding. 






























