Com-Power Corporation
Com-Power Corporation has been a supplier of instrumentation for EMI / EMC Testing (electromagnetic compatibility), telecommunication ( Part68 ) and product safety ( UL / IEC CSA) testing since 1989.
- (949) 459-9600
- (949) 635-0329
- sales@com-power.com
- 1679 Placentia Avenue
Costa Mesa, California 92627
United States of America
-
Product
Spectrum Analyzer
-
Spectrum Analyzer from Com-Power of have a frequency range of 9 kHz up to 3.2 GHz. With their light weight, small size, and friendly user interface, the SPA-900TG offer a bright easy to read display, powerful and reliable automatic measurements, and plenty of powerful features. Applications include broadcast monitoring/evaluation, site surveying, EMI precompliance, research and development, education, production, and maintenance.
-
Product
Bulk Current Injection Probes
-
The Com-Power CLCI-100 and CLCI-400 are precision bulk current injection probes designed for conducted immunity testing. The CLCI-100 covers 10 kHz to 100 MHz, while the CLCI-400 extends up to 400 MHz and complies with MIL-STD-461 and RTCA DO-160. Both models feature split-core ferrites for easy cable insertion and are compatible with calibration fixtures for accurate RF injection and monitoring.
-
Product
Antennas
-
Com-Power EMI / EMC broadband and tuned antennas cover the frequency range of 9 kHz - 40 GHz. Most electronic products are required meet the various international EMC regulatory standards before they are introduced to the market. Com-Power provides a wide range of EMI antennas and accessories. We also have the capabilities to assist you with custom EMC antennas for special applications to meet your exact needs.Contact us today to learn more about our EMC broadband test antennas.
-
Product
LISNs - Single Phase
-
Com-Power single-phase LISNs cover 9 kHz to 400 MHz in five series — 1x, 2x, 3x, 4x, and 5x — with current ratings from 20 A to 100 A for CISPR 16, ANSI C63.4, MIL-STD 461, DO-160, and CISPR 25 conducted emissions testing.
-
Product
EM Clamps
-
The EM Clamp or a Bulk Current Injection Probe (BCIP)can be used for IEC/EN 61000-4-6 tests on ports/cables for which no Coupling/Decoupling Network (CDN) is available.
-
Product
Comb Generators
-
As an EMC testing lab, the accuracy of your results is key to your reputation. Maintaining this accuracy requires properly calibrated quality equipment. Comb generators are an important piece of EMC radiated emissions testing equipment - one that can save you time and money by reducing your reliance on full, annual recalibrations of your site and instrumentation.
-
Product
LISNs - Three Phase
-
Com-Power three-phase LISNs in three series — LI-3P-1X (CISPR/ANSI, 150 kHz–30 MHz), LI-3P-2X (CISPR/ANSI V-AMN, 9 kHz–30 MHz), and LI-3P-4X (MIL-STD-461, 10 kHz–10 MHz) — covering 16 A to 100 A per phase for conducted emissions testing of industrial, commercial, and military three-phase equipment in Delta and Wye configurations.
-
Product
Antenna Kits
-
Com-Power offers five portable antenna kits suitable for offsite EMC testing. These kits are supplied with a custom hard plastic carrying case which has individual compartments for all the included items.
-
Product
Current Probe Calibration Fixtures
-
Calibration fixtures are used for calibration of Coupling Loss/Transfer Impedance of current probes and BCI probes, as well as for the calibration of test levels for conducted immunity/susceptibility tests using BCI probes.
-
Product
Surge Generators
-
Surge Generators by Com-Power Corporation provide you to test your electronics to lightening simulation.
-
Product
LISNs - TEMPEST
-
Com-Power TEMPEST LISNs cover 5 kHz to 1 GHz with two complementary models — LIP-120 and LIP-1000 — rated at 10 A for TEMPEST power line conducted emissions testing in classified government, military, and diplomatic environments.
-
Product
Near Field Probes
-
A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.
-
Product
Tripods For EMC
-
These tripods are a great choice for EMC testing. They are made of non reflective nylon and wood material. The antenna height can be easily adjusted by moving the center slotted rod up or down. The tripods are designed to be portable, so that the antenna can be placed at the appropriate location for testing. The legs can be folded for easy transport and storage.
-
Product
System Controllers
-
System Controllers feature multi-device control, variable speed control, fiber optic interface with antenna mast and turn table, full control via front panel or PC software, on-site antenna calibration, 19" 3U rack-mountable, and a 3-year warranty.