Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
Resistance Calibration
-
Process Instruments maintains fractional part-per-million accuracy with a state of the art resistance calibration facility. Specialized services include precision resistor manufacture, resistor and shunt repair, characterization of alpha and beta temperature coefficients and the determination of barometric effects on resistance values.
-
Product
Robot Calibration
-
Achieve improved absolute robot positioning accuracy via dynamic robot calibration using API’s Laser Tracker and Active Target a self-orienting motorized 360° rotation SMR.
-
Product
Test Equipment Calibration
-
ISO:17025 AccreditedANSI Z540-1-1994 AccreditationA2LA Certificate 2374.01
-
Product
Humidity and Temperature Calibration
-
The most comprehensive temperature, humidity and dew-point calibration offering on the market today.
-
Product
Electrical Calibration
-
Beijing GFUVE Electronics Co.,Ltd.
Checking condition , performance , sensitivity and accuracy of any electrical device.
-
Product
Lens Calibration
SpyderLENSCAL
-
A fast, reliable method of measuring and adjusting the focus performance on your camera and lens combinations.
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Platforms
-
The use of switching systems to route instrumentation and stimulus signals to appropriate test points on a unit under test has a very crucial role to play in most electronics test systems. The sharing of test resources, connection of calibration references, load management, and many other functions are all managed by the switching system, the switching system acts as the interface between the unit under test (UUT) and the test equipment.
-
Product
NIST Calibration for D400A-AT
D400A-AT-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
VFL Power Meter -- VFL & OPM
TM203N
-
◇ Self Calibration◇ Self Auto Off◇ High Accuracy, high ,High sensitivity, high linearity-◇ Stable VFL Output◇ Set the REF Value◇ Real-time display of the power consumption◇ Interchangeable connectors: FC/ SC◇ Rubber Out shell, increased the protective properties for field work
-
Product
Calibration Blocks
-
Are used to assess and refine measurement equipment's correctness, and these calibration blocks come in various sizes and shapes.
-
Product
VisualIMPACT Software
-
CEAST VisualIMPACT software is designed to control CEAST Pendulums and Drop Tower Series, manage tests and offer a user-friendly interface when using the Data Acquisition System. It records force and absorbed energy data related to impacts, visualizes and helps analyze the results and calculates resilience. The operator is guided through parameters setup by means of tables describing strikers and specimens that are filtered according to the test type and international standard selected. In the case of instrumented tests, many possibilities for data analysis and visualization are made available. The results are shown through comprehensive and customizable graphs and can be filtered by break type (only specimens with a selected break type are shown). Working with groups of test, the software performs a statistical analysis, and the operator can pick and discard single test results. Different measurement units can be selected. It is possible to print reports and to export data totally or partially. Recent improvements include the possibility to set a number of user profiles, including graphic settings, default printing options, advanced parameters for data analysis and so on, switching quickly from one another when looking at results. The introduction of a new Data Acquisition System (CEAST DAS 64K) in the Impact product line has also triggered a number of new capabilities for the SW, which is now able to process a more comprehensive calibration file for instrumented tups and hammers and manage DAS configurations with a wider range of data acquisition channels.
-
Product
Luminance Colorimeter
XYL-VI
-
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.
-
Product
PCI Strain Gauge Simulator Card, 4-Channel, 350 Ohm
50-265-014
Strain Gauge Simulator
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
20 GHz Differential Probe with ProLink Interface
DH20-PL
Interface
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Impulse-Calibration-System
KAL1000 Series
-
The impulse calibration system KAL1000 is a modular system to perform tests on complete impulse voltage measuring systems and on digital recorders for the measurement of high impulse voltages and impulse currents. The modular design allows an optimal KAL-configuration depending on the actual application.Additional, this modularity allows to up-grade or modify and existing KAL1000 system in case of changing or additional requirements
-
Product
Cable Length Meters
CLM-1000
-
*Measures these AWG wire gages: 18, 16, 14, 12, 10, 8, 6,4, 2 , 1/0, 2/0, 3/0, 4/0*Measures these kcmil wire sizes: 250, 350, 400, 500, 600, 750, 1000*Eight user-programmable settings for other gages*Powered by (6) 1.5V AA batteries*Replacement calibration rods (pair) available as CLM-ROD, UPC 02721*Replacement Kelvin clips (pair) available as CLM-CLIPS, UPC 02722*Feet
-
Product
Humidity Sensors
-
A humidity sensor is a device that detects and measures water vapor. TE Connectivity (TE) manufactures a complete range of calibrated and amplified RH sensor products to measure relative humidity. Based on our robust capacitive technology, these humidity detectors provide accurate measurement of dew point and absolute humidity by combining relative humidity (RH) and temperature (T) measurements.
-
Product
Transducer Calibration
m+p SensCal
-
Regular transducer calibration is an essential requirement for maintaining the accuracy, reliability and repeatability of the results obtained from a measurement system. m+p international’s m+p SensCal program provides a quick and simple process for calibrating accelerometers (piezo-electric with charge output or IEPE, piezo-resistive, capacitive) in your laboratory, as well as velocity or displacement transducers.
-
Product
Continuous Time Interval Analyzers
GT668PXIe-40
-
GuideTech’s GT668PXIe-40 PXI 3U form factor, meets industrial standard chassis with an expandable platform, achieving optimal test system at low cost. High accuracy 50MHz time base with NIST traceable calibration. Some of the GT668PXIe-40 measurements include Jitter measurements, PLL & Clock Jitter, Spread Spectrum Modulation, PLL Lock Time, Frequency, Period, Pulse Width, Skew, Tpd, Rise/Fall Time, Time Interval Error and more.
-
Product
Acceleration Pickup Calibrator
VX-1100A
-
VX-1100 is for a piezoelectric type accelerometer which is widely used for measuring vibration. This compact calibrator is effective for checking operation(sensitivity) sensors before measurement to acquire accurate data.Built-in sensor amplifier and display in one unit allows direct reading of the sensitivity. This calibrator excites the sensor at a frequency of 159 Hz and acceleration of 10 m/s2 rms, and the sensor outputs can be used as calibration signals for a vibration measuring system.
-
Product
Calibration Hand Pumps
-
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
Product
Laboratory Centrifuges
-
Centrifuge systems are designed for the development, test, evaluation and calibration of accelerometers and a variety of inertial devices. Centrifuges provide a cost-effective solution for simulating high-"G" environments in the laboratory. They support testing of devices such as MEMS-based Inertial Measurement Units (IMUs), low-cost quartz or silicon sensors, Ring Laser Gyros (RLGs), Fiber-Optic Gyros (FOGs), fuzes and crash sensors.
-
Product
Capacitive Discharge Testers
-
For IEC Testing of residual voltage after plug disconnect. The CDT-240 disconnects the line at the voltage peak and analyzes results to the requirements of various Standards, allowing quick results. Scope output for viewing decay waveform. Presets for EN 61010, EN 60065, EN 60950, EN 60601-1 and EN60335. Recommendations for Pluggable Type B equipment. NIST calibration supplied; A2LA calibration available. 16A option for testing large equipment.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
-
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
NDT Testing Instruments
-
Portable vibration calibrator, digital Brinell hardness tester, digital low load Vickers hardness tester, Rockwell hardness meter
-
Product
TEM Cells
-
Transverse Electro Magnetic (TEM) cell or Crawford cell (named after its inventor) is used to generate accurate electromagnetic waves over a wide frequency range: DC (0 Hz) to GHz., EM waves generated in the cell propagate in transverse mode and have the same characteristics as a plane wave. It can be used to calibrate E-field broadband probes for testing radiated E-field immunity as well as for measuring radiated emission from a product with a spectrum analyzer/EMI receiver.TEM cell generates a consistent electromagnetic field for testing small RF devices such as wireless pagers, receivers, portable phones, etc.
-
Product
Model AM-IIIB: Paper Moisture Meter
AM-31B3
-
Portable digital paper moisture meter to measure single sheets. Permits instant and non-destructive moisture detection measurement on all types of paper and paperboard. Pre-programmed with 11 different Calibration Curved with option to select a field. Fast and accurate. Uses Radio Frequency to minimize effects of pH and temperature variations
-
Product
Phase Noise Generator / Calibrator
PNG-A
-
Noise eXtended Technologies S.A.S.
The PNG-A is a high precision generator used in Test and Measurement instruments calibration. It is a Signal Generator with precisely computed phase and amplitude noise characteristics. With its wide frequency offset range, 1Hz to 1 MHz offset, and its programmable Phase and Amplitude noise in real time, this is the ideal standard to calibrate phase noise analyzers, Signal Source Analyzers and Spectrum Analyzers.
-
Product
LCR Meter
M162
-
M162 LCR meter is a great complimentary tool to most multi-meters. Regular multi-meters are good in many way. But they usually have rather limited or even no ability for capacitance, inductance, and sub-ohm resistance measurement. The addition of a M162 LCR meter will overcome this deficiency. The DIY kit version of M162 is very easy to build. No special calibration is required to achieve ~1% accuracy.





























