Microphone Calibration
an accurate sound units of measure to facilitate comparison to and adjustment of instruments.
See Also: Microphone Calibrators, Sound Calibration
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Dimensional Calibration
-
Process Instruments certifies Gage Blocks with a state-of-the-art Pratt & Whitney Gage Block Comparator. Outside and Inside Micrometers, Depth Micrometers, Height Gages, Calipers and Dial Indicators can be repaired and calibrated to manufacturers'' specs.
-
Product
Calibration
-
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
Product
VNA Calibration Kits
-
Vector Network Analyzers are commonly used to accurately determine the RF Characteristics of microwave components. Accurate Testing of microwave circuits means eliminating measurement errors and ensuring repeatable results. This is only possible when the network analyzers can be calibrated with known and true calibration standards.
-
Product
PAT Calibration Checkboxes
-
Seaward's special PAT calibration checkboxes are designed to provide a fast and simple means of confirming that test readings remain effective during those working periods between formal re-calibration.
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Calibrator for Vibration Transducers
HD2060
-
Hand-held calibrator for vibration chains with frequency 15.915 Hz and levels 1 m/s² and 0.1 g, and frequency 159.155 Hz and levels 10 m/s² and 1 g. With LCD display.
-
Product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
-
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Field Strength Calibration Probe
-
Beijing KeHuan Century EMC Technology Co,.LTD
Three-axis omnidirectional 100kHz~6GHz light transmission.
-
Product
Oscilloscope, Calibrated, 2 Channel, 100 MHz, 1 GSPS, 25 kpts, 3.5 ns
72-8710A CAL
-
The 72-8710A CAL from Tenma is a digital storage oscilloscope with 100MHz bandwidth, 2 analogue channels. The digital storage oscilloscope provides a complete set of trigger modes including edge, pulse, alternate and storage modes including set-up, wave, bitmap. It has a 7 inches wide screen LCD display and supports plug and play USB storage device. Communication with and remote control of computer through the USB device.
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
Product
Vibration Calibrator
SV 111
-
SV 111 vibration calibrator is the State of the Art instrument designed for human vibration measurements according to ISO 8041. The design of the calibrator is based on the triaxial reference accelerometer and microprocessor controlled shaker. These both features assure excellent stability of the calibration levels and their frequency independently from mass of the testing object, like also indicate improper test object fixing by monitoring of shaker vibration in all three axis simultaneously.
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
Pressure Calibrator
HPC40
-
AMETEK Sensors, Test & Calibration
The HPC40 Series handheld pressure calibrator is the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -20 to 50°C. You can count on the same accuracy whether measuring pressure, current, voltage, or temperature.
-
Product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL
-
The 72-7755 CAL from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
Product
Energy Meter Calibration
GF312D1
-
Beijing GFUVE Electronics Co.,Ltd.
The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
Calibration Measurement
-
The process of comparing a measuring instrument's readings to a known, more accurate standard to detect and correct errors.
-
Product
Chemical Calibration
-
Trescal provides full Chemical Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Chemical Calibration services can be delivered at your site or at our lab. Accreditations for our chemical calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Calibration Devices For Spring Impact Hammer
CX-TF06A
-
Shenzhen Chuangxin Instruments Co., Ltd.
Calibration Devices for Spring Impact Hammer
-
Product
PROBE MICROPHONE ICP
377B26
-
Open Circuit Sensitivity (at 250 Hz)Frequency Range (+2.2/-4.9 dB)2 to 20000 HzLower Limiting Frequency (-3 dB)Inherent Noise<45 dB(A) re 20 Pa Dynamic Range(3% Distortion Limit)EnvironmentalTemperature Range (Operating)-40 to +158 F-40 to +70 C[5]
-
Product
30KHZ Measurement Microphone
M30
-
Used on countless full-scale concert tours, as well as in scientific research laboratories, tropical rainforests, and rocket testing facilities, the M30 has proven to be a lab-grade audio instrument that can handle any environment.
-
Product
Automatic Calibration Module
ACM2509
-
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Speed-O-Calibrator
16470
-
The Speed-O-Calibrator consists of two sections, control box and drive unit. The control box is stored inside the drive unit for easy portability. The control box weighs less than 6 lbs and is used in the cab of a locomotive to control the speed of the Axle Alternator Drive Unit. The Drive Unit drives the Axle Alternator at various speeds while the user verifies that the correct speed is displayed in the cab. The test system provides a complete test of the speedometer system, including all types and paddle lengths of Axle Alternators.
-
Product
Multi-Axis Calibrator
XM-60
-
XM-60 is a laser measurement system capable of measuring errors in six degrees of freedom along a linear axis, simultaneously from a single set-up. It provides a powerful diagnostic tool measuring all geometric errors in the axis from a single capture. For users of volumetric compensation XM-60 provides quick and accurate method of data population. All measurements are made optically allowing use in any orientation.
-
Product
ICP Electret Surface Microphone
130B40
-
Low-profile surface pressure microphone and preamp, prepolarized
-
Product
Coaxial Calibration Kits
-
Designed to provide accurate calibrations of network analyzers in the DC to 18.0 GHz range.
-
Product
Laser Power Meter Calibration Services
-
Following the successful setup of our UKAS accredited laser testing laboratory we have now set up a calibration laboratory in our Bournemouth premises for the purpose of offering laser power meter calibrations. We are able to undertake NPL traceable calibration of laser power meters at any of the following wavelengths:





























