Temperature
a measurement of heat or cold.
-
product
Loss Tangent M in Dielectric Oil
TAND220A
The measuring instrument type TAND220A complies with the international standard IEC 61620. The instrument is based on the so-called "low-amplitude, low-frequency alternating current square wave method" and allows accurate measurements of conductivity and relative permittivity. Conductivity measurement in the range of 0.01 pS/m to 20,000 pS/m allows the use of this instrument for quality control of high resistivity liquids even at room temperature. The TAND220A works with a low test voltage and also with a low test current so that it does not represent a danger for the operators.
-
product
Thermal Microscope Stage
TS-4MP
With our TS-4MP Thermal Stage, a specimen on a microscope slide or culture dish can be maintained at any temperature between -20°C and +60°C. Setup is easy, takes little time, and the controller will regulate the stage temperature to within +/-0.1°C
-
product
Pressure Testing
Types of Pressure Testing Performed at GTS:*Hydrostatic Pressure Testing*Leak Pressure Testing*Burst Pressure Testing*External Pressure Testing*Pressure Testing at Temperature Extremes*Vacuum Pressure Testing*Differential Pressure Testing*Cyclic Pressure Testing
-
product
High Resolution Handheld Infrared Camera
FLIR T650sc
The T650sc infrared camera offers thermal and visual imagery, excellent spot size resolution, and reliable temperature measurement accuracy —all at an affordable price. Technicians, engineers, and scientists will appreciate features such as a built-in digital camera, voice annotation, laser target locator, GPS, Multi Spectral Dynamic Imaging (MSX®), UltraMax™ image enhancement, auto-image rotation, and more. The tiltable IR unit gives you great flexibility and allows you to conduct your experiments fast and in a comfortable position.
-
product
Oxygen-free Voltammetry cell
SVC-3C
By using SVC-3C oxygen-free Voltametry cell, researchers can get rid of influence of oxygen in the cell by bubbling nitrogen gas, and also run the experiments at low temperatures.
-
product
10 MHz to 55 GHz Noise Sources
CNS346 Series
The Spanawave CNS346 Series is designed for precision noise figure measurement applications. The superior VSWR characteristics reduce multiple reflections of the test signals and significantly increase the measurement accuracy of most noise figure set-ups. The CNS346 Series noise sources have broadband coverage and extremely good temperature and voltage stability, for the finest noise figure meter-compatible laboratory standards. Outputs of 6, 15.5 and 22 dB ENR are available, allowing the units to accurately measure noise figures up to 20 ,30 and 36 dB respectively.
-
product
Low Noise Amplifiers for Radio Amateurs
Our Low Noise Preamplifiers are remarkable for extremely low noise, excellent SWR, high efficiency and a high IP3. The Low Noise amplifiers are especially selective and absolute stable therefore oscillation is avoided. Even if you have a bad SWR. This is the reason why radio amateurs and club-stations all around the world trust in Kuhne electronic equipment. The products are perfect for use in contests, EME, MeteorScatter, Aurora and Tropo DX. Small mechanical measurements and technical innovations from the professional sector, e. g. milled aluminium cases, enable high temperature stability and tower mounting. Numerous contest victories, records and first contacts with a country were and are achieved with Kuhne products. Don't compromise and get technology from Kuhne electronic!
-
product
Refractometer Calibration Oils
Calibration Oils are one of the most commonly used materials for calibrating refractometers as they have good traceability, particularly to NIST. Having a high temperature co-efficient, Calibration Oils are best used where strict temperature control is adopted either by Peltier or external waterbath between 10 and 75 °C as well as with refractometers operating at ambient by making use of supplied tables or an RI/°C Temperature Calculator as long as the prism temperature is reliably known.
-
product
Chloride Test System
C-CL-2000
The C-CL-2000 produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reaction of a weighted sample placed in an extraction liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight - is covered.
-
product
High Temp Lab Dyeing Machine
TD220
TESTEX Testing Equipment Systems Ltd.
Suitable in various galley proofs dyeing and the laundering firm test. The highest operating temperature reaches 140 oC. Equipped with programmable micro computer control system, repeatable working condition. May simulate the actual operating conditions.
-
product
Handheld Economic Process Calibrator
VA701
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This Multifunction calibrator combined voltage. current .resistance .thermocouple temperature .RTD in one device.
-
product
Mini Coax, Contact, ITA, RG178
610103130
Primary mating contact 610104141. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 milliohms @ 0.5 Amp & always < 10 milliohmsCable Specifications RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
COM Express Type 10 Mini Module With Intel® Atom® X5 And X7 Processor
CEM310
The CEM310, a COM Express Type 10 Mini module, supports Intel® Atom® x5 and x7 processors (codename: Apollo Lake) in a board size of 84mm x 55mm. It has 8GB of DDR3L onboard memory and an optional 64GB eMMC memory. The Intel® Atom®-based COM Express Type 10 Mini module comes with a variety of I/O and expansion options including four PCIe x1 lanes, one Gigabit LAN port with Intel® i210IT Ethernet controller, two USB 3.0, eight USB 2.0, two SATA-600, four digital I/O channels, HD Codec audio, one DDI, one LVDS, one LPC, one SPI, two serial TX/RX and one I2C to meet customer requirements. Aside from the rich I/O options, the CEM310 has a wide voltage input range of 4.75V to 20V to meet the varying voltage input requirements for automotive or transportation applications. In addition, it supports an extended operating temperature range from -20ºC to +70ºC or optional -40ºC to +85ºC to ensure stable and reliable operation in harsh environments. The CEM310 supports watchdog timer, hardware monitoring functions, SMBus as well as smart battery (optional).
-
product
PLD Systems
Pulsed Laser Deposition
Is a versatile thin film deposition technique. A pulsed laser (~20 ns pulse width) rapidly evaporates a target material forming a thin film that retains target composition. This unique ability of stoichiometeric transfer of target composition into the film was realized first by the research team led by Dr. Venkatesan at Bell Communications Research, NJ, USA, nearly 30 years ago while depositing high temperature superconducting (YBa2Cu3O7) thin films. Since then, PLD has become the preferred deposition technique where ever thin films of complex material compositions are considered. Another unique feature of PLD is its ability for rapid prototyping of materials. The energy source (pulsed laser) being outside the deposition chamber, facilitates a large dynamic range of operating pressures (10-10 Torr to 500 Torr) during material synthesis. By controlling the deposition pressure and substrate temperature and using relatively small target sizes, a variety of atomically controlled nano-structures and interfaces can be prepared with unique functionalities.
-
product
DC/DC Converter 150 W
110RCM150-12DMQ
DC/DC converter with 150 W from Bel Power Solutions | input ranges 43.2 - 154 VDC | output 12 V | operates in temperatures from -40 to +70 °C | provides 10 ms hold up time and built in O-ring FET
-
product
C/I Non-Contact IR
Infrared Thermometer
*Safe, non-contact temperature measurement.*Laser spot indicator shows approximate center of target measurement area*Display temperatures in either Fahrenheit or Celsius.*Adjustable emissivity for optimum temperature reading accuracy on a wide range of materials and surfaces.*Min, Max, Difference and Average temperature functions.*Backlight display for easy readings in any environment.*Auto power off for longer battery life
-
product
Electrochemical Measurements
A portable pH-meter from CHAUVIN ARNOUX is ideal for mobile applications: in the field, in the laboratory or in production. It can be used for quick, accurate, professional measurements of pH, Redox potential and temperature.
-
product
Temperature logger with probe-40 to 125C
TK-4023
Temperature recorder 16,000 readings capacity High accuracy and reading resolution Fast data offload Low battery monitor User-programmable alarms User-replaceable battery
-
product
Multivariable Transmitters
The Multivariable transmitter measures and calculates the mass flow as a function of differential pressure DP as well as absolute pressure and the temperature. Therefore it should be used whenever DP flow measurement needs a compensation of temperature and pressure. The main advantage is to have just one single device in the field instead of several transmitters and a mass flow calculator.
-
product
RTD Thermometers
Precision Platinum Temperature Sensor, High Accuracy With 0.01°C Resolution, Automatic Locked Push-pull Connector For Easy Connection, Large Back Light LCD
-
product
Thermalert Monitoring Thermometer
TH-5
The TH-5 is one of our most economical precision thermometers in the Physitemp product line. The TH-5 offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-5 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
product
Process Control Actuators
SM-6000
*Torque range up to 35,256 Nm (26,000 lbf.ft)*Up to 313° rotation*Double O-ring sealing*Continuous unrestricted modulating duty*Manual override standard*HART®, Profibus® & Foundation Fieldbus® available*Automatic torque limiting*Self-locking drive system to hold in last position and prevent backdriving up to 125% of torque rating*AC input power (1-phase and 3-phase)*Temperature range from -40° F to 185° F (-40° C to 85° C)*Manual override standard
-
product
PCI High Density Pecision Resistor Card, 9-Channel, 3Ω To 52.4kΩ
50-298-033
The 50-298-033 is a high density programmable resistor card with 9 channels which can be set between 3Ω and 52.4kΩ with 1Ω resolution The 50-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems. It is particularly well suited to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.
-
product
Oven Temperature Profile
Temperature profiling provides an effective method for measuring the actual environmental and product temperature during the cure process - essential for ensuring quality finish and a successful cure of a powder coating.
-
product
Capacitors - Beam Lead
Macom Technology Solutions Holdings Inc.
MACOM’s MMI-9000 and 9100 Series Chip Capacitors feature high stand-off voltage and low dielectric loss leveraging nitride/oxide dielectric layers. Gold bonding surfaces, top and bottom provide ease of bonding and minimum contact resistance. MACOMs beam lead capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which are features that produce devices with excellent long-term stability.
-
product
Temperature and Relative Humidity Mini Data Logger with Display
HD206/226/207/227
Minidatalogger Temperature - Temperature/Relative Humidity. Monitoring, reliable over time, working range -30...+80 °C instrument, -40...+105 °C probe with cable.
-
product
Melting-Point Apparatus
Shanghai Selon Scientific Instrument Co. Ltd.
A laboratory instrument used to determine the melting point of a solid by heating it in a sealed capillary tube and observing the temperature at which it melts.
-
product
Buoyancy Level Sensors and Switches
ABB offers a complete line of buoyancy point level switches for just about any chemical, petroleum or general process application. This family of products include horizontal floats, vertical floats, and displacer switches of all kinds. ABB's simple and reliable design offers great flexibility with custom insertion lengths, temperature ratings to 1000ºF/ 38ºC. Pressure ratings to 5000 psig/345 bar, and a wide selection of alloys. The ABB buoyancy switches are the highest quality and cost efficient solution to industrial liquid level point sensing.
-
product
Thermometer Hygrometer Data Logger
S3120
Data logger is designed for record of temperature and humidity. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter.
-
product
Datalogger
S0110E
Temperature datalogger is designed for record of temperature. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper adapter.