Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Calibration Services
Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).
-
product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-H200-1
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3C
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1Q1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard Resistors for Temperature Measurement
Measurements International Ltd.
High Stability, Split Guard Circuit, Internal Temperature Sensor, Custom Values Available, Includes Calibration Data.
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74C
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1Q1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
product
Electrical Calibration
We offer electrical calibration on a wide range of instruments covering all brands and types of electrical testers. Being the only calibration company in Ireland to have Fluke's state of the art 5320a Multi-product calibrators allows us to match or in many cases exceed the manufactures calibration such as Fluke, Megger, Kewtech etc, but for a lot less cost and downtime to you.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I35-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Calibrator for Battery Charger-Analyzers
VCM-100
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
product
Standard Pitch Spring Probes
Other than spring probes with gold plating, we have spring probe with anti-solder migration coating and plating that were developed by KITA. We also have anti-solder migration material for plunger tip. These are all included in “MARATHON” series. They have wide range of tip type for various use for every popular total length.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25Z-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL DU
The 72-7755 CAL DU from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
product
Standard Digitizer
725S Family
The 725S family is a digitizer capable of recording waveforms along with performing advanced algorithms for online digital pulse processing (DPP). Utilizing DPP Firmware, users can acquire quantitative physical parameters (Integrated Charge, Pulse Shape Discrimination with very fine time resolution, Pulse Height Analysis) as well as read out waveforms with automatic pulse identification and baseline suppression on channel basis (Zero-Length Encoding and Dynamic Acquisition Window). The wide range of DPP algorithms supported by the 725S make it a “must-have” for any type of nuclear physics application.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1UN-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard IR Target Projectors
Santa Barbara Infrared’s 14000Zi Series reflective infrared target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies and 300 Series Target Wheels. SBIR also offers a standard athermal target projector with a 5.7° field of view (FOV).
-
product
Standard Electromagnetic Vibrator
KD-9363-EM
King Design Industrial Co., Ltd.
The purpose of vibration testing is to make a series of controllable vibration simulation in lab, no matter generated by natural or man-made vibration environment; such as waves, tidal flaps, wind, earthquake or rain and so on. It is to test if the product is capable of sustaining the vibration environment exerted from transporting or usage along its effective life cycle; and certify the standard of design & functional requirement of product. The value of vibration testing is to confirm the reliability of products and effectively screen out the bad products in factory; avoiding damages occurred at arrival; and to assess the failure analysis on the non-performing products; expecting to reach a high standard, high-reliability products. The vibration test stresses on the continuity and fatigue; and contributes to the understanding of product’s status under vibration circumstance in a normal environment; and avoids the product’s unpredictable damage caused under certain vibrating frequency for a long time.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4F
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Multifunction Voltage and Current Calibrator
MC140i
Multifunction calibrator MC140i is ideal for calibration of voltmeters, ammeters, DMMs and panel meters. AC/DC voltage 1uV to 1000V. Current 50uA? to 1000A using test coil. Deviation control along readout. 0.0035% basic dc accuracy. 0.03% basic ac accuracy. Supplied with RS232 interfaces. UKAS/NIST Traceable
-
product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-R
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
product
NIST Calibration for D410-A
D410-A-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Standard - 6.00 (170.00) - 14.00 (397.00) Feed Through Probe
P2447-1W
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 225Test Center (mm): 5.72Full Travel (mil): 300Full Travel (mm): 7.62Recommended Travel (mil): 200Recommended Travel (mm): 5.08Overall Length (mil): 1,145Overall Length (mm): 29.08
-
product
Partial Discharge Measurement Calibrator
DAC-CP-2
DAC-CP-2 is a calibrator for partial discharge measurements. The electric charge enables to generate up to max 10000pC. It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).
-
product
Capacitance Standard
SCA Series
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
product
Standard Gain Horn Antenna
KSHA-BJ260-25-2.92L
Standard Gain Horn Antenna, Frequency21.7~33GHz, Gain 25dBi, Linear Polarization, 2.92-Female
-
product
Calibrated, Integral Isolator Noise Sources
Calibrated, Integral Isolator Noise Sources by Pasternack
-
product
Power Calibrator And Protection Relay Test Set
CP11B
Calmet Smart Calibration Devices
Single phase, class 0.02 and 0.05 power quality calibrator up to 120A and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.





























