Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
One Phase Electric Power/Energy Calibrator
MC133
The MC133 master unit model is a one phase electric power/energy calibrator. It can supply the device under test with single phase precise voltage and current with calibrated phase shift along with DC voltage and current capability. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. Simulated electric power can be set independently for each phase. Frequency can be set from 15Hz to 1 kHz with resolution 0.001Hz to 0.01Hz. The MC133 Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20mA or 10V for direct calibration of various types of power transducers and wattmeters.
-
product
Calibration Services
Trescal US is accredited to ISO/IEC 17025, ANSI/NCSL Z450-1 and ANSI/NCSL Z540.3 through A2LA. Trescal has one of the largest scopes of accreditation in the country for electronic, physical and dimensional domains as well as being a factory-authorized service center for many International manufacturers.
-
product
MTB Calibration Adapter
2450-CAL-30
The MTB Calibration Adapter (Catalog No. 2450-CAL-30)is a socket adapter that’s designed to bring phase A, B, and C current and potentials of a TESCO Multi-Position Test Board to an external RD-30 reference standard for calibration of the Test Board.
-
product
Portable Temperature Calibrators
Portable temperature calibrators (dry-well calibrators) are electronic controllers which automatically, quickly and dryly supply a temperature. Due to the high reliability, accuracy and simple operation, portable temperature calibrators are particularly suitable as a factory/working standard for the automatic testing and/or calibration of temperature measuring instruments of all types. A major advantage is offered by the large sleeve diameters and the fast, stable temperature control, since, as a result of these characteristics, the time for calibration can be used very effectively.
-
product
Standard 1.24 (35.00) - 2.94 (85.00) Battery Probe
CCA-006
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
product
Standard Voltage 37 Pin D-Type Cables - Connector to Unterminated for Pickering
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T75
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Traditional Handheld Refractometer Calibration
104XXVP Series
Two-point NIST Traceable Certified Calibration for the following refractometers: 10430VP, 10431VP, 10433VP, and 10440VP.
-
product
Pressure/Vacuum Calibrators
Compact, completely self-contained unit designed for calibrating and testing pressure gauges, transducers, pressure switches, and other pressure-sensitive instruments up to 2,000 psi with an accuracy of ±0.25% of full scale.
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-7
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-3W1S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
Standard Voltage 37 Pin D-Type Cables - Calibration Cables for Pickering
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 37-pin D-type calibration port connector.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Vector Network Analyzer (VNA) Simulator – Standard
S94050B
S94050B puts flexible S-parameter analysis into your own computer. Dive deeper into measurements captured on a network analyzer or develop and optimize test programs before deploying them onto an instrument.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1V-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
product
Resistor Calibration Box
RCB-411
Standard Electric Works Co., Ltd
● The RCB-411 is used to verify and proof High Voltage Insulation Testers. Both Analogue and Digital Insulation Testers can be calibrated.● Caution: a. Before testing, make sure the front panel, terminals are clean and dry. If not, wipe them with cloth. b. Use high voltage silicone wires. Otherwise the reading will be incorrect.
-
product
Service, Modernization, and Calibration Serivices
In addition to production of new material testing machines, TIRA offers inexpensive service, modernisation and calibration. Our modular design makes it possible to modernise complete measuring technologies, electromechanical and hydraulic material testing machines in a cost-efficient manner.According to all requirements of force-measuring systems DIN EN ISO 7500-1, calibration DIN EN ISO/IEC 17025 and test options according to EN 10002.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T1-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Frequency Calibrator
VCH-313
The frequency calibrator VCH-313 is designed to determine the frequency error and calibrate frequency standards of various types based on the signals of the NSC SNS GLONASS/GPS .
-
product
The Standard R&D Wafer-Lifetime Tool
WCT-120
Best available lifetime measurement accuracy. Measure lifetime and surface recombination for a wafer of any quality or crystallinity.
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Calibration Kit
N611
*N611 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm. * Connector Type: N-type.
-
product
Documenting Calibrators
We offer documenting calibrators, for us the “documenting” calibrator means a calibrator that can store the calibration results into its memory and upload them to calibration software. This benefits you as you don’t need to carry pen and paper and spend time in making notes and typing them into software.
-
product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52D
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
product
Standard Attitude Gyroscopes
5000B-series
The 5000B is an air-driven gyro that has a pictorial horizon mask and fixed airplane. The mask moves to indicate climb, dive, and bank. Bank and pitch attitudes are displayed so that the pilot’s sensing of the gyro indication is the same as the interpretation of the relation between the wings of the aircraft and the natural horizon during visual flight.
-
product
Standard 0.30 (8.50) - 1.06 (30.00) Battery Probe
BIP-3
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
product
Transducer Calibrator Systems
Unholtz-Dickie Calibration Systems have earned their place in industry as the standard for calibrating accelerometers and velocity transducers. The Models 660C & 680C are UD''s latest generation of automatic calibration systems, both utilizing the expanded features of the i5 based APEX SL Windows vibration control system.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02