Time & Frequency
See Also: Time Domain, Time Reference
-
Product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
Frequency Extender
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX52
Frequency Extender
The Keysight N5293AX52 is a broadband frequency extension module designed for use with Keysight’s new PNA / PNA-X-based millimeter-wave solutions. It is a compact, lightweight, and ruggedize frequency extender module with built-in bias tee for pulsed DC bias operation. It interfaces with the Keysight N5292A test set controller. The modules allow users to extend the frequency coverage of a base PNA / PNA-X Series network analyzers to a range of 10 MHz to 110 GHz. For more information about cable and accessories for use with network analyzers, please visit Network Analyzer Accessories.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
Product
DC - 12 GHz Packaged High Efficiency Divide by 8 Prescaler
HMMC-3128-TR1
Frequency Divider
The HMMC-3128-TR1 is a packaged DC - 12 GHz divide by eight prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
Product
35/50 GHz 2/4 Port TDR/TDT Remote Sampling Head for the 86100D DCA-X
N1055A
Time Domain Reflectometry Module
Bandwidth options: 35 or 50 GHz (upgradable)Edge speed (10-90%, typical): 18 ps (35 GHz) or 7 ps (50 GHz)Channel options: 2 or 4 per module (upgradable) with independent skew control and up to 16 channels per 86100D mainframe Ultra-thin remote head: 1.6 m phase-stable cable, 2.92 mm (35 GHz) or 1.85 mm (50 GHz) connectors, and integrated 67 GHz diode limiters for ESD/EOS protection TDR fixture de-embedding removes effects of fixtures, cables or probes connected between remote heads and DUT
-
Product
110 GHz Frequency Extender
N5293AX51
Frequency Extender
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
40-72 GHz Doubler
1GC1-8048
Frequency Extender
The 1GC1-8048 is a balanced diode frequency doubler consisting of two Schottky diodes and a coplanar balun structure. The doubler provides 15 dB conversion loss and 17.5 dBc 1st and 3rd order feed-thru for input frequencies between 20 and 33.5 GHz. This IC is fabricated in HFTC's InGaP/GaAs heterojunction bipolar transistor (HBT) process that provides excellent uniformity, reliability and 1/f noise performance.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
PXIe-6674T, OCXO PXI Synchronization Module
781037-01
Timing and Synchronization Module
PXIe, OCXO PXI Synchronization Module—The PXIe‑6674T generates and routes clocks and triggers between devices in a PXI Express chassis as well as to other PXI and PXI Express chassis or third-party instrumentation. The PXIe‑6674T unlocks the advanced low-voltage differential signaling (LVDS) trigger signals PXIe‑DStarA, PXIe‑DStarB, and PXIe‑DStarC, on PXI Express while fully supporting the PXI trigger lines. The PXIe‑6674T can generate two types of clock signals: a highly stable 10 MHz clock based on an onboard precision oven-controlled crystal oscillator (OCXO) reference and a second clock from the direct digital synthesis (DDS) clock generation circuit.
-
Product
120 GHz Frequency Extender
N5295AX53
Frequency Extender
The N5295AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
DC - 12 GHz High Efficiency GaAs HBT MMIC Divide by 2 Prescaler
HMMC-3022
Frequency Divider
The HMMC-3022 is a DC - 12 GHz divide by two prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
High Frequency Probe
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Hydrogen Frequency & Time Standard
CH1-1006
-
The hydrogen frequency and time standard Ch1-1006 is designed to generate highly stable, high-frequency, spectrally pure sinusoidal 5, 10, 100 MHz and pulsed 1 Hz signals and for the behavior of time-frequency measurements.
-
Product
Hydrogen Frequency & Time Standard
CH1-1033
-
The hydrogen frequency and time standard Ch1-1033 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main areas of application: – public service of time and frequency; – ground control complexes of radio navigation systems; – radio interferometry with extra long base.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
Redundant Frequency and Timing Systems
-
A unique feature of our frequency standards and distribution amplifiers is that the two separate parts of the redundant system are identical and can easily be inter-changed, for maintenance purposes. What we mean by this is that that we don't have a "Master" unit and a "Slave" unit. Whatever unit is powered up first becomes the master unit and the other becomes the slave unit.
-
Product
Multifunctional Time Relays
-
Self Supply: Operating with internal battery without power supply (MCB200)Battery life of 10 years or 1,000,000 switching (MCB200)Easy setup with user-friendly menuIn addition to its main functions, offering flexible solutions that are tailored to objective with trigger-controlled rich sub-functionsWith memory feature, saving time and state information in the memory when supply is cut off, and resuming on when supply is backPerforming functions based on real time clock with its digital time setting
-
Product
Precision Time Protocol
IEEE-1588
-
Meinberg Funkuhren GmbH & Co. KG
As a high-stability Grandmaster Clock in IEEE 1588-2008 networks, the MEINBERG NTP time servers with highly accurate PTP clients ("slaves", such as the PTP270PEX or PTP SYNCBOX ) At the same time as the current absolute time.
-
Product
Frequency Extender
DC100
-
The DC100 system can be installed in the HP8568B(see H96 option below) without compromising the performance of the original instrument. The spectral purity and power accuracy of the primary band ( 100hz to 1.5Ghz) are insured from corruption by careful design of the DC100 system. Additional protection of the primary band is guaranteed as the DC100 system is automatically switched off (all power removed) when in primary band operation.
-
Product
Time Domain Reflectometer
IRG 2000
-
Cable fault location with the BAUR IRG 2000. The IRG 2000 impulse reflection measurement unit or time domain reflectometer is a handy, easy to carry device for single-phase cable fault pre-location. It is used in combination with a surge voltage generator on low-, medium- and high-voltage cables 0 - 65 km in length. It can also be used on live cables carrying voltage up to 400 V.* Easy and quick cable fault location* Light, compact and manageable* Main unit for the tried-and-tested pre-location method* Ideal for integration in measurement systems
-
Product
Frequency Standards
-
Precision Test manufacturers a complete range of frequency standards. This includes rubidium and OXCO models either free running or controlled by an external reference (GPS, GLONASS, Galileo, 1pps, 5 MHz, 10 MHz, IRIG-B etc). Output frequencies typically 1 MHz, 5 MHz, 10 MHz, 10.23 MHz, 13 MHz, 100 MHz or bespoke frequency.
-
Product
Timing Solutions
-
Professional-grade, network-based timing, clock, and synchronization equipment designed for digital broadcast, live production, and media control rooms.
-
Product
Transition Time Converter, 250ps
15432B
Transition Time Converter
The new design of these transition time converters ensures very low signal reflection far beyond the 3 dB point, unlike conventional converters. Reducing the signal transition-times also increases the overall pulse-performance for overshoot/reflection sensitive applications. The converters are fitted with SMA connectors, one male, one female. These converters have been designed to convert the fixed transition-times of the Keysight 8133A 3 GHz timing generator (<100 ps transitions) to slower, fixed transition-times (150 ps, 250 ps, 500 ps, 1 ns, 2 ns) hence reducing the signal bandwidth. All transition-times are from 10% to 90% of amplitude.
-
Product
Frequency Converters
-
Analytic Systems' Single and 3-Phase Sine-Wave Converters deliver output power ranging from 250 VA to 5000 VA. Our Frequency Converters also generate nominal output voltages of 115 VAC or 220 VAC, at frequencies of 50, 60 or 400 Hz. A broad range of input voltages are available.
-
Product
Frequency Sources
-
PMI offers a full line of Digitally Controlled Oscillators (DTOs), Dielectric Resonator Oscillators (DROs), Voltage Controlled Oscillators (VCOs) and Frequency Synthesizers covering various frequencies in the 50 MHz to 40 GHz range. All models are designed to withstand stringent military ground or airborne environments. These models use the latest internal digital calibration techniques such that frequency drift over the operating temperature range is minimal. All units offer fast switching speeds and stable frequency outputs with low phase noise. If you do not see exactly what you need, please e-mail your requirement to sales@pmi-rf.com so we can propose an instant solution.
-
Product
Military Timing Solutions
-
Brandywine is AS9100C certified and supports the environmental testing and specific interface standards needed for simple integration within military hardware. Brandywine offers many standard options for our military timing products including cesium frequency standards for international applications as well as the option to customize each product to fit your specific timing needs.





























