Time & Frequency
See Also: Time Domain, Time Reference
-
Product
20-50 GHz Doubler
1GC1-8038
-
The 1GG1-8038 is a passive diode frequency doubler. It is specified to operate with a 2050 GHz output frequency. Conversion efficiency is usually around -12 dB. The device has low 1/2 and 3/2 spurious output, typically 15 dBc or better. The doubler can be biased through onchip resistors to allow operation at low input levels. Up to 22 dBm at the input can be accommodated. Onchip DC blocking capacitors are included at the input and output.
-
Product
DC - 12 GHz High Efficiency GaAs HBT MMIC Divide by 4 Prescaler
HMMC-3024
-
The HMMC-3024 is a DC - 12 GHz divide by four pre scaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
Product
Transition Time Converter, 500ps
15433B
-
The new design of these transition time converters ensures very low signal reflection far beyond the 3 dB point, unlike conventional converters. Reducing the signal transition-times also increases the overall pulse-performance for overshoot/reflection sensitive applications. The converters are fitted with SMA connectors, one male, one female. These converters have been designed to convert the fixed transition-times of the Keysight 8133A 3 GHz timing generator (<100 ps transitions) to slower, fixed transition-times (150 ps, 250 ps, 500 ps, 1 ns, 2 ns) hence reducing the signal bandwidth. All transition-times are from 10% to 90% of amplitude.
-
Product
120 GHz Frequency Extender
N5295AX01
-
The N5295AX01 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
PXIe-6674T, OCXO PXI Synchronization Module
781037-01
-
PXIe, OCXO PXI Synchronization Module—The PXIe‑6674T generates and routes clocks and triggers between devices in a PXI Express chassis as well as to other PXI and PXI Express chassis or third-party instrumentation. The PXIe‑6674T unlocks the advanced low-voltage differential signaling (LVDS) trigger signals PXIe‑DStarA, PXIe‑DStarB, and PXIe‑DStarC, on PXI Express while fully supporting the PXI trigger lines. The PXIe‑6674T can generate two types of clock signals: a highly stable 10 MHz clock based on an onboard precision oven-controlled crystal oscillator (OCXO) reference and a second clock from the direct digital synthesis (DDS) clock generation circuit.
-
Product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
-
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
DC - 12 GHz High Efficiency GaAs HBT MMIC Divide by 2 Prescaler
HMMC-3022
-
The HMMC-3022 is a DC - 12 GHz divide by two prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
Product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
-
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
Product
110 GHz Frequency Extender
N5293AX03
-
The N5293AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
High Speed PXIe Digital IO Card - 32 Channels, Extendable up to 256 Channels in One Chassis
Model 33010
-
Chroma 33010 is a high-density 100MHz PXIe digital IO card designed for characterizing, validating, and testing a variety of digital and mixed-signal ICs. Each IO Card consists of a Sequencer Pattern Generator (SQPG) and 32 Channels of fill ATE-like features. The 33010 IO card is expandable up to 356 channels. Some unique features of the 33010 include an on-board SQPG, per pin timing/levels/PMU/TFMU, multiple time domains, and multithreaded testing for complex IC testing. Each channel is also equipped with 64M vector memory, 16 timing sets with on-the-fly timing change, and per pin timing and frequency measurements up to 400 MHz.
-
Product
RF High Frequency Probes
-
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module
786999-02
-
6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.
-
Product
350 MHz RF Frequency Counter, 10 digits/s
53210A
-
Single-channel, RF frequency counter One 350 MHz input channel, plus optional second channel (6 GHz or 15 GHz)10 digits/second resolution Built-in math analysis and color, graphical display (trend and histogram)LXI-C/LAN, USB, GPIB Optional: Lithium Ion Battery BenchVue software enabled: Do more with your PC and instrument together, no programming required. Easily control your counters, quickly build automated tests and log data for faster analysis and save precious time.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
DC - 12 GHz Packaged High Efficiency Divide by 8 Prescaler
HMMC-3128-TR1
-
The HMMC-3128-TR1 is a packaged DC - 12 GHz divide by eight prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
Product
K-50 Series Probes
-
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
Product
Transition Time Converter, 250ps
15432B
-
The new design of these transition time converters ensures very low signal reflection far beyond the 3 dB point, unlike conventional converters. Reducing the signal transition-times also increases the overall pulse-performance for overshoot/reflection sensitive applications. The converters are fitted with SMA connectors, one male, one female. These converters have been designed to convert the fixed transition-times of the Keysight 8133A 3 GHz timing generator (<100 ps transitions) to slower, fixed transition-times (150 ps, 250 ps, 500 ps, 1 ns, 2 ns) hence reducing the signal bandwidth. All transition-times are from 10% to 90% of amplitude.
-
Product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
-
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
-
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
120 GHz Frequency Extender
N5295AX53
-
The N5295AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
-
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
Circuit Breaker Tester
GDGK-307
-
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
1) Closing and opening time measurement of 12 channels2) Max difference of closing or opening time measurement of three phases3) C-O and O-C time measurement4) Rated operation sequence test5) Bounce time and frequency measurement of breaker closing6) Circuit breaker closing and opening speed measurement7) Travel-time, coil current-time curve of circuit breaker operation measurement8) Travel and clearance of circuit breaker measurement9) Variable DC circuit breaker operation power supply10) Closing arc resistance value and connected time measurement11) Closing time and opening time of graphite circuit breaker measurement12) Print test results by internal micro printers
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
-
Your product description goes here.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
-
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
40-72 GHz Doubler
1GC1-8048
-
The 1GC1-8048 is a balanced diode frequency doubler consisting of two Schottky diodes and a coplanar balun structure. The doubler provides 15 dB conversion loss and 17.5 dBc 1st and 3rd order feed-thru for input frequencies between 20 and 33.5 GHz. This IC is fabricated in HFTC's InGaP/GaAs heterojunction bipolar transistor (HBT) process that provides excellent uniformity, reliability and 1/f noise performance.
-
Product
Audio Spectral Analysis Freeware
PSELab
-
Power Spectrum Estimation Laboratory
"PSE Lab" is a freeware Windows application useful to estimate power spectrum and time frequency distribution of signals. To estimate power spectrum, the application uses following methods: periodogram; using the simplex algorithm to estimation of complex exponential model optimal parameters; using the quasi-Newton algorithm to estimation of complex exponential model optimal parameters; least squares Prony method; modified least squares Prony method; Burg method; modified covariance method; MUSIC..
-
Product
Oscilloscope Device
-
Oscilloscope Devices are flexible, software‐defined instruments that are versatile enough for both time‐ and frequency‐domain measurements and are offered in industry-standard form factors like PCI and USB. They feature up to eight channels that can sample at speeds up to 2 GS/s. The devices also feature numerous triggering modes, deep onboard memory, and driver software API that includes data streaming and analysis functions.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module
786999-01
-
6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.