Filter Results By:
Products
Applications
Manufacturers
Charge Sensitive Preamplifiers
See Also: Detectors
-
product
Charge Sensitive Preamplifier-Discriminator
A101
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
product
Digital Multi Channel Analyzer
DT5770
The DT5770 is a compact portable 16k Digital MCA for Gamma Spectroscopy, integrating analog front-end with programmable gain and possible AC coupling. It is ideally suited for high energy resolution semiconductor detectors, like HPGe and Silicon, connected to a Charge Sensitive Preamplifier (CSP). The unit can also properly operate directly connected to a PMT with inorganic scintillators (e.g. Nal or Csl scintillators), provided exponential pulse shape and decay time above 200 ns.
-
product
Preamplifier
The UBBV series are external, extremely low-noise broadband preamplifiers that can be mounted to any SPECTRAN spectrum analyzer. They are ideally suited for spectrum analyzers and oscilloscopes as well as antennas of all manufacturers and are supplied with extensive accessories.
-
product
Preamplifiers
Preamplifiers recognize the extremely low amplitude AE signal produced from AE sensors, and convert the signals into amplified and usable forms. As applications and testing conditions vary, project needs may change as well. Physical Acoustics offers an entire line of preamplifiers for a variety of testing requirements. Operating in conjunction with our specialized AE software, preamplifiers also moderate signal size during the data collection process, helping to produce accurate results.
-
product
Preamplifier
Is designed for the amplification of measuring signals, e.g. weak signals of near field probes with high resolution.
-
product
Microphone preamplifier
PRE-01
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
product
Preamplifiers
A.H. Systems'' Preamplifier line is an excellent choice with a rugged design, no hassles with soldering your own power leads and they improve overall system sensitivity by at least 20 dB. All of A.H. Systems'' Preamplifiers come with a 12-volt (or 15-volt) DC regulated power source. A low voltage indicator confidently allows you to power the amplifier with your own external 12-volt DC battery. This makes it a convenient choice for field measurements. See table below for amplifier specifications.
-
product
Universal Preamplifier 14
UP14
For Two Dimensional Magnetic Recording (TDMR) and Heat-assisted Magnetic Recording (HAMR) Headamplifiers. Universal Preamplifier 14 (UP14) is designed for TDMR and HAMR Head Amplifiers. With new Guzik RWA4000 TDMR, UP14 allows to process signals from three Read Channels. It also supports two high speed data channels for Write data and Laser data. UP14 has two channels for dynamic TFC control and allows to program TFC power per sector and close loop TFC power control in each channel. UP14 can generate two programmable modulation signals for write data and laser data with bandwidth up to 20 MHz. UP14 consist of two boards. The first UP14 RW Board processes high-frequency signals: read-back signals, write data and laser data. The second UP14 Control Board provides power, control and low-frequency signal generation: TFC, write data modulation and laser modulation.
-
product
In-Line Charge Amplifiers
The in-line charge amplifier is used to excite structures or machinery with a definable impulse force. Resonances are identified by impulse, an important measurement parameter for the study of dynamic behavior. The 4705A1 is a fast turn on time, 50 mV/pc, in line charge amplifier with BNC jack connectors on each side.
-
product
Charge Integrator Amplifiers
AD8488
Analog Devices’ charge integrator amplifiers convert the charge acquired by X-ray or photodiode detectors to a voltage. The channels are composed of CMOS transistors, using typical high input impedance CMOS gates. The integrators generate charge dependent voltages using a range of selectable capacitance values that accommodate a broad range of input charge values. The integrators are followed by single-ended input to differential output voltage amplifiers where offset and low frequency noise voltages are subtracted from the input voltages.
-
product
Charge Meter
NK-1001A/NK-1002A
Probe-type charge meter that can easily measure the amount of discharge charge that causes static electricity destruction in the manufacturing, inspection, and assembly processes of electronic devices.Many ESD phenomena that impair electronic devices are represented by the CDM ( Device Charging Model). The CDM is a model that represents a phenomenon in which a high peak current flows at high speed when the device itself is charged and its external electrode is grounded. The coulomb meter measures the amount of discharge charge, which is the integral value of the current, with high accuracy.
-
product
Charge Controller
The intelligence of an AC charging station or an AC charging infrastructure is largely determined by the charge controller used. A smart charge controller has the primary task of controlling and monitoring the charging process of an electrical vehicle.The features that characterise a smart charge controller include communication with a backend system and the associated authorisation of users, as well as the efficient distribution of load currents by means of dynamic load management to prevent an overload of the existing AC system.
-
product
Preamplifiers
LNA Series
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
product
Current Preamplifier
1212
The Model 1212 Current Preamplifier is designed as a low cost, gerenal purpose, benchtop instrument to provide a high performance detection system for small ac and dc currents. The 1212 operates with a virtual ground at its input which mitigates unpredictable high frequency rolloff due to input cables and stray capacitance.
-
product
X-Ray Preamplifier Power Supply
The X-ray Preamplifier Power Supply (XPPS) provides power for 50 or more preamplifiers. The 19-inch rack-mount or benchtop unit contains linear power supplies that generate +/-12V @ 5.1 Amperes and +/-24V @ 3.6 Amperes, with very little noise.
-
product
Charge Plate Monitors
Our charge plate monitors the voltage of the battery and the voltage of the battery.
-
product
DC-DC Charge Pumps
Charge pumps – inductorless boost converters – from ams operate at up to 90% efficiency.
-
product
DC/DC With UPS And Charge Controller
PCM-PS402-512
WINSYSTEMS’ PCM-PS402-512 is a wide input range, triple output PC104 DC/DC converter with a built-in battery charger and uninterruptable power supply (UPS) controller. Designed for harsh environments, the power supply operates from -40° to +85°C without a fan or heatsink making it ideal for industrial applications.
-
product
Low Noise Preamplifier
The UPL-3001 preamplifier is a high performance solution for the low-noise amplification of ultrasonic signals. Designed for signals ranging from 0.5 to 300 MHz, the small and lightweight, rugged unit is perfect for remote applications. This is ideal for P&C, TT, AUT or TOFD inspection.
-
product
Capacitor Charging Power Supplies
Excelitas Capacitor Chargers are tailored to meet your exact needs by configuring modular platforms based on proven designs. Single-phase AC input designs are capable of up to 6 kW of output power and our three-phase designs provide up to 35 kW of output power. A modular design approach results in lower cost, higher reliability, and faster time-to-market. Typical applications for capacitor charging power supplies include flashlamp pumped laser systems (Nd: YAG, pulsed lasers, dye lasers, Intense Pulsed Light Systems (IPL) and aesthetic Medical Laser Systems, Medical Holmium YAG Laser), excimer lasers, pulsed UV curing and sterilization, radar and RF systems.
-
product
Smart Refrigerant Charging Kit
HUB4
UEi Test & Measurement Instruments
The HUB4 gives the ability to wirelessly get Vapor and Liquid pressures via the WPP1 probes and Vapor and Liquid temperatures via the WPC1 probes, all via the free UEi Hub App. Easy to use and a rugged design make the App and probes an excellent addition to any technician's toolbox.
-
product
Mm-Wave High Sensitive Power Meters
The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.
-
product
Microphone Preamplifier
HT426E01
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
product
Surface Charge and Zeta Potential
Surface analysis is a vital method for qualifying new materials in technical and biological applications. Surface charge analysis empowers users to closely monitor the surface chemistry from small particles in the nanometer range up to large wafers. Gain insights into modifications resulting from surface treatment and surface interactions with natural environments under near-ambient conditions. Get a competitive edge in optimizing existing products and developing new ones using the Anton Paar instruments which offer zeta potential measurement for a wide range of applications.
-
product
Battery Charge and Discharge Tester
HTCFDK / 791
Wuhan Huatian Electric Power Automation Co., Ltd.
The voltage monitoring information of single battery is simple, safe and accurate with wireless relay access.
-
product
Sensitivity Testing
Response Dynamics Vibration Engineering, Inc.
Sensitivity testing involves making predictions of system response to environmental disturbance. The significance and importance of the system sensitivity estimates is very often overlooked. This gets companies in trouble and is one of the top reasons why we are called upon to provide timely solutions. Most teams are focused on getting their product to work and get it out the door. An engineering team will often not know how to quantify what to expect in the customer environment and how to test for those expected disturbances. We design hundreds of sensitivity tests and can explain the important concepts to consider in designing the tests and making the right measurements that allow for sound estimates of system response. This is an important expertise we use in our vibration, acoustic and magnetic field consulting services.
-
product
USB Preamplifier, 2 to 50 GHz
U7227F
The U7227F, 2 to 50 GHz USB preamplifier is designed to bring reliable gain and low noise figure to measurement systems improving the overall system performance and reduce systematic errors; a total solution to the X-Series signal analyzers to perform noise figure measurement
-
product
Precision Current Preamplifier
SIM918
Stanford Research Systems, Inc.
The SIM918 Current Preamplifier is ideal in applications in which the input offset voltage must be kept to a minimum. The DC voltage difference between the two inputs (current input and voltage bias) is accurately measured every 2 seconds, and is nulled.
-
product
Battery Charge & Discharge Test System
ITS5300
ITS5300 battery charge and discharge test system is designed for a variety of power batteries (lead acid, nickel hydrogen, lithium batteries, super capacitors, hydrogen fuel cells, etc.) for performance testing.
-
product
EV Charging Station Tester
EV : ChargeCheck
The EV Industry’s Charging Station Tester of Choice. • Simulates an electric vehicle • Tests J1772 (type 1) tethered leads • Tests IEC62196 (type 2) sockets • Tests IEC61851-1 mode 3 communication compliance • Tests for correct polarity • Tests for earthing presence • Tests contactor actions.