Time Reference
An absolute measure of time.
See Also: Time, Timers, Time Interval, GPS Time, Time Code, Time Domain, Time Standards, Timing, Frequency Synthesizers, Time & Frequency, Clocks
-
product
Digitizer
742 Family
The 742 is the Switched Capacitor Digitizer family, based on the DRS4 chip by PSI, with the highest sampling frequency (5GS/s) and channel density. It can record very fast signals from scintillators coupled to PMTs, Silicon Photomultipliers, APD, Diamond detectors and others, and save them with high efficiency and precision for advanced timing analysis. The 742 family has an additional channel (two channels in case of VME boards) which can be used as time reference for time of fight measurements. The resolution of this kind of measurements can reach up to 50 ps.
-
product
IRIG B to NTP/SNTP Converter
Signals & Systems India Private Limited
IRIG B TO NTP/SNTP CONVERTER – SPC-INS-1010 is a compact DIN rail mountable protocol converter unit which synchronizes and maintains the timing and frequency requirement of power and process industry equipment using IRIG-B signal obtained from GPS receiver. It provides nanosecond accuracy when external time references are not available. It has the storage facility to store the system log file. It delivers NTP, SNTP, PFC-Pulse, RS232 & RS485 outputs. The system enables configuration and monitoring through Web-based application. It supports a wide range of power supply input either 90V-260V AC/DC or 18-36VDC or 36V-72VDC.
-
product
NTSC Test Signal Generators
Provides an economical means for generating the most common SD analog composite video reference timing signals required to operate various SD analog composite video switchers, effects generators, VTRs/VCRs, cameras, video edit controllers, and other professional video equipment.
-
product
Low Cost Microwave Wideband Electro-absorption DFB Transmitter
MT62 (40KHz~33GHz)
Hangzhou Huatai Optic Tech. Co., Ltd.
MT62 series microwave DML optical transmitter, are able to transmit 33G microwave RF signal with long distance, wide bandwidth, and flat responsibility. They provide an outstanding linearity fiber optical communication for analogue and digital wideband microwave application. Due to avoidance of using expensive coaxial cable or wave guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless; timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s and 60Gb/s high speed communication system.
-
product
GPS Time and Frequency Standards
Our range of GPS disciplined Rubidium Oscillator, OCXO and TCXO, low cost and stable, time and frequency references in a variety of rack mount and desktop sizes to suit all applications. For a technical discussion of GPS go here or select a link below for product information.
-
product
Personal Gamma Radiation Dosimeter
EcotestCARD
The radiation monitoring badge EcotestCARD allows storing dose accumulation history with real time reference in the non-volatile memory, and communicating it to the computer. If the programmed threshold levels of gamma dose or its rate are exceeded, light and audio alarms are actuated.
-
product
Intelligent Reference
TM-4D
The Intelligent Reference/TM-4D™ breaks new ground for time and frequency references. For the first time, it is possible to generate and distribute both analog and digital signals to multiple instruments and locations with just one product that fits in a single rack space. The TM-4D is three instruments in one: an Intelligent Reference/TM-4™ precise time and frequency reference, a digital signal distribution amplifier and an analog distribution amplifier. And it eliminates the need for multiple boxes.
-
product
Pulse & Delay Generators
The benchtop pulse generators feature a fast risetime and low jitter. Our most popular digital delay pulse series 575 and 577 generators are now available with selectable time references. With up to eight channels of delay and width control, each individual channel's reference can be set either to the trigger or to any other channel. So look below if you require a picosecond pulse generator or nanosecond pulse generator for your application.
-
product
GPS Master Clock
Signals & Systems India Private Limited
GPS Master Clock System – MCS-GPSMC-1010 is a 3U Card rack type, 19” Rack-mountable Redundant GPS Time Server which synchronizes and maintains the timing and frequency requirement of power and process industry equipment using a signal obtained from any one of the sources like GPS or GLONASS or Time protocols such as NTP and IRIG. It distributing the same time signal through several types of interfaces. It provides redundancy for Power and GPS receiver to increase reliability and offers protection against time synchronization failure. The system is field-upgradeable and an extremely flexible system, designed to handle time synchronization requirements today and in the future. It provides nanosecond accuracy when external time references are not available. It has a storage facility to store the system log file. It delivers NTP, SNTP, IRIG-B, PFC-Pulse, DCF77, BCD parallel data, Ethernet Fiber Optic & RS485/RS232 outputs. System enables configuration and monitoring through Web-based application. It supports a wide range of power supply either 90V-260V AC/DC or 18-36VDC or 36V-72VDC. Power supply model can be mixed and matched as required by the user, depending upon power supply options available at the installation site.
-
product
Conventional Panel-mounted Type Power Amplifier Control Unit
PAT01
PAT01 is a power amplifier control unit that controls timing output and reference signal test source for power amplifier.
-
product
Timing And Sync
Precision timing is critical for defense and commercial industries and powering essential network operations. Safran offers secure time servers and solutions for accurate network synchronization, ensuring security, compliance, and adherence to best practices. Safran excels in delivering precision timing solutions, including NTPNTP, or Network Time Protocol, is a widely used networking protocol that enables computers and devices to synchronize their system clocks with a reference time source. It ensures accurate timekeeping in computer networks by allowing devices to obtain precise time information from NTP servers, which are typically synchronized to highly accurate atomic clocks. NTP is essential for various applications and services that rely on synchronized time, such as network security, authentication, and data logging. time server appliances and GPSGlobal Positioning System is a navigation satellite system. See also master clocks globally.
-
product
Rubidium Instruments
Our range of atomic / rubidium disciplined time and frequency standards in a variety of enclosures and sizes to suit all appliations. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
product
E-Band Signal Analysis Reference Solution
The E-band signal analysis reference solution provides an effective measurement solution for today’s wideband signals as well as emerging communications standards. With the M1971E waveguide harmonic mixer, which provides a 55 to 90 GHz input; Keysight oscilloscopes, which provide excellent signal integrity; and the powerful 89600 VSA software, you have a high-quality wideband measurement solution. A simple user interface also provides integrated mixer setup, correction and LO optimization, allowing for accurate measurements.
-
product
4CH 16-Bit 80 MS/s PXI Express Digitizer
PXIe-9834
The ADLINK PXIe-9834 PXI Express digitizer provides high speed, high quality data acquisition with four input channels supporting up to 80MS/s sampling and 16-bit data resolution. This allows simultaneous recording of signals on all channels with no interchannel phase delay.The PXIe-9834 features external digital trigger input and triggers from the PXIe system timing slot and reference clock from the PXIe chassis, making it easy to achieve high simultaneous channel count recording of 8, 12, 16 and 20 channels. The PXIe-9834 is also equipped with 1GB of onboard memory for data buffering before transferring back to system memory. The PCI Express x4 Gen1 data bus is has enough bandwidth for direct streaming of ADC data back to system, if necessary.
-
product
AC Reference Modules
NAI offers a variety of AC reference modules that provide a drive capability to 5 VA. The units are transformer-isolated and operate over a frequency range from 47 Hz to 10 kHz. These modules are specifically designed for rugged defense, commercial aerospace, and industrial applications.
-
product
Reference Thermometers
Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
product
Reference Thermometers
Reference thermometers (standard thermometers) are, due to their excellent stability and their geometrical adaptations, ideally suited for applications in industrial laboratories. They enable easy comparative calibration in baths, in tube furnaces and in dry-well calibrators. The advantage of reference thermometers is the wide temperature range, and with this, their flexible operation. Furthermore, with their low drift, a long service life is ensured.
-
product
Voltage References
Renesas' wide selection of voltage reference (Vref) circuits offer accurate and stable reference voltages unaffected by external influences such as variation in temperature, input voltage and time.
-
product
Rubidium Reference Oscillator
LPFRS-01
Rubidium reference generator LPFRS-01 is designed to generate a highly stable reference and clock frequency signal.
-
product
Primary Reference Generator
VCH-001
The Primary Reference Generator (PEG) VCH-001 is designed to generate the highest accuracy clock signals in a digital communication network. Main areas of application: – synchronization in telecommunication networks.
-
product
Reference Pressure Transducers
These Baratron® capacitance manometers offer our highest level of presure measurement accuracy making them ideal for calibration transfer standards.
-
product
Reference Magnets
Series MT
The reasonably priced WUNTRONIC standard reference magnets offer the possibility in a simple way of being able to calibrate or to check magnet measuring instruments like Gauss Meter/Tesla Meter with the respectively accompanying probes in a defined magnetic field.
-
product
Fast Timing Discriminators
Fast timing discriminators enable the counting of narrow pulses at very high counting rates, and/or precisely marking the arrival time of these same pulses. They are designed to achieve the best time resolution and the highest counting rates by operating on the fast-rising detector signal.
-
product
RF Reference Sources
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
product
Time Domain Reflectometers
HL1100 Series
HYPERLABS HL1100 Series TDR instruments provide high-performance test and measurement capabilities for use in the field or in the lab. These instruments are used for applications such as fault detection in cables and interconnects, impedance characterization, time of flight analysis, water level measurement, and more.
-
product
Precise Timing Measurement
LED-Panel
Image Engineering GmbH & Co. KG
This is the ideal measurement device to determine shutter and shooting time lag, autofocus time, burst frame rate and the exposure times of digital imaging devices.
-
product
Compact Timing Systems
NanoSync IV & NanoSync IV Low Profile
The NanoSync IV is a small form factor GPS Position, Navigation, Time (PNT) and Frequency reference system that provides multiple reference outputs and includes support for NTP & PTPv2 IEEE 1588-2008. The NanoSync IV has a Rubidium oscillator and is available with a civilian C/A GPS receiver or SAASM (Rockwell-Collins MPE-S GB-GRAM or Trimble Force 22E MRU GPS receiver) for military users. The NanoSync IV is packaged in a small, rugged enclosure ideally suited for embedded electronic warfare applications.The NanoSync IV-SA-Rb has been demonstrated to be compliant to the Joint Airborne SIGINT Architecture (JASA) Version 3.0, Annex 1, for Time, Frequency, Navigation and Geodesy (TFNG), making it suitable for Electronic Warfare (EW) COMINT and ELINT applications in fixed site, airborne and shipboard environments.
-
product
Video Timing Meter
VTM
The VTM Video Timing Meter is used to bring CCTV cameras into synchronism so that monitors and/or recorders can be switched among cameras without causing “rolling” of the picture.
-
product
Time Domain Reflectometer
ETDR 10A-1