Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Standard Helmholtz Coils
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
product
Multifunction Calibrators
To automate and optimise the calibration process Time Electronics' EasyCal Calibration Software can be used with compatible multi product calibrators. Increase speed of calibration, consistency of results and produce calibration certificates and reports to ISO 9001, ISO 17025, and other quality standards. With comprehensive features it provides the ideal platform for an efficient calibration program.
-
product
Three Phase Electrical Power Calibrator
6003A
The Fluke Calibration 6003A Three Phase Electrical Power Calibrator is the most cost-effective way to get the superior accuracy and performance of three independent phases in one instrument. It is an ideal solution for calibration laboratories, electronics manufacturers, electric utility meter shops, and other organizations that manufacture and maintain energy meters, power quality analyzers, and similar tools.
-
product
Class 2 Sound Level Meter
SP79
The SP79 is a Class 2 sound level meter for on-site measurements in accordance with Noise at Work legislation in industrial and office environments. Featuring A and C frequency weighting and fast and slow time weighting, the compact design can be handheld, or mounted on a tripod for longer term monitoring of Min / Max values. Detailed recording and analysis can be made using the AC and DC outputs. The SP79 complies with BS EN 61672-1:2003 and is supplied with a detachable windshield and hard carry case. The large high contrast display includes both digital reading and analogue bar graph. An optional Class 2 sound level calibrator is available to verify accuracy before and after readings in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB.
-
product
- Optical / RF Converter
OPT 80
Calibrated measurement of the optical power of satellite and terrestrial TV signals distributed in optical fiber Calculation of optical signal losses on distribution Measurement of digital parameters (BER - MER - NM etc.) of optical signals converted into RF Visualization of optical carriers in RF Field Metric Spectrum Analyzer Power Meter Optical Field Meter Display Optical RF Power Supply Line Link Meter (LNB power supply ) Optical LNB power supply 13V 500mA with short circuit and overload managementAcquisition of optical measurements using the field meter Data Logger Option: certification of the OPT80 calibration and optical power measurements
-
product
Spectroradiometer
SpectroCAL MKII
Cambridge Research Systems Ltd
High-performance spectroradiometer with NIST traceable calibration makes extremely accurate colorimetric measurements over the entire visible spectrum, even of narrow band sources.
-
product
Waterproof Portable conductivity meter
CyberScan CON 400
Waterproof and dustproof to IP67 Deliver lab-accurate results stamped with time and date for GLP-compliant researchConveniently auto-ranging with up to 5-point push button calibration
-
product
Dead Weight Pressure Tester
Unitech Scales And Measurements Pvt. Ltd
Dead Weight Pressure Gauge Tester is ideal for testing and calibration of pressure gauges,pressure transducers,recorders,digital calibrators etc. The system used in the dead weight is vertically mounted precision lapped piston and cylinder assembly with accurately calibrated mass for loading the piston. Pressure is built easily by single cylinder pump at very high rate. The whole system is housed inside a stainless steel case with elegant look. Pressure ports are provided to fix the gauges to be tested. Acrylic see-through oil tank is designed to use it as oil reservoir.
-
product
Automatic Transmission & Engine Oil Pressure Tester
34500
Check oil pressure in automotive transmissions and engines. Adapters provide coverage of most domestic and imported cars and light trucks. Gage calibrated from 0-600 PSI (0-4,000 kPa & 0-7.0 BAR). Includes 6 feet of oil proof hose and 10 assorted fittings. Supplied with instructions in a durable vinyl pouch.
-
product
Efficient All-In-One Test Solution for Low-Cost IoT Devices
KT RFCT 2400
The low price point creates a cost effective means for testing wireless communication units, while generating a favorable cost to performance ratio.The calibrated RF test system has a small footprint, integrating seamlessly into test system infrastructures via a single Ethernet connection. GPIOs control the DUT and peripherals. The test system enables communication interfaces like SPI, I2C, UART and CAN. Simple Go/No-Go tests can be performed in parallel. The KT-RFCT 2400A features a 70 MHz to 6 GHz frequency range and includes non-signaling and signaling connections. Bluetooth signaling standards are supported up to 4.1 as well as BT-LE. WIFI signaling standards supported are a, b, g, n and ac.The KT-RFCT 2400A is the perfect test system for a wide range of applications, such as Bluetooth, Infotainment, Keyless Entry, Tire Pressure Measurement, GPS and WIFI.
-
product
Source Phase Control
S96088B
The S96088B allows users to set calibrated, arbitrary phase differences between two signal sources running on the E5080B ENA.
-
product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Reference Voltage Measurement Cell
C-80
Cells C-80 and C-100 are used as reference devices for measuring voltage during calibration and adjustment of OLT-series testers.
-
product
Coaxial Attenuators Set
11583C
The Keysight 11583C contains a set of four 8493C attenuators 3, 6, 10, and 20 dB furnished in a handsome walnut accessory case. The Keysight 8493C are APC-3.5 connectors with a maximum frequency of 26.5 GHz. This set is ideal for calibration labs or where precise knowledge of attenuation and SWR is desired.
-
product
Precision Pressure Transducers
Precision and digital pressure transducers, somemtimes known as precision pressure sensors, convert pressure into an analog or digital signal proportional to the pressure being sensed. A precision pressure transducer (also referred to as a pressure transmitter) are used to monitor and or control sensitive pressure processes. They can also be used as high accuracy transfer standards or as a factory working standard for testing or calibrating a variety of pressure measuring instruments. With an accuracy as high as 0.008 % of reading, these pressure transducers can be found in laboratories or in production environments where a high degree of precision and accuracy are required. Each transducer is calibrated in Mensor's 17025, A2LA certified laboratory.
-
product
Reference Thermapen®
Until now you would have spent hundreds more to get this level of accuracy in a NIST-Traceable standards thermometer. Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
product
Open eVision 3D Studio
Ease the configuration and the setup of a laser triangulation scanner using the Coaxlink Quad 3D-LLESimplify the calibration procedureDisplay interactive Depth Maps, 3D Point Clouds and ZmapsFree of charge
-
product
Current Detectors
On our website you will find current detectors that are ideal for measuring AC or DC voltage. Current detectors are irreplaceable for inspection work and maintenance. We offer the following: voltage detectors, voltage leak detectors, voltage power detectors, Current clamps ideal for measuring AC or DC voltage. metric detectors, current detectors and more. These high quality current detectors include the capacity to measure many other parameters, such as capacity, resistance, power (both by way of clamps or by means of a hand held digital device with external clamps with a range of one or three stages). The current detectors are like the majority of our measurement instruments in that they meet and excel ISO standards. This calibration is done in a laboratory and comes with an accompanying certificate. All of our current detectors can perform the demanding tasks in each industrial sector regardless of the technical problem you encounter. If you can't find the current detectors you are looking for, please contact us and we will help you find the best solution to suit your needs by calling our offices on: UK customers +44(0) 23 809 870 30 / US customers (561) 320-9162 and our technical staff will advise you regarding our measuring instruments. Our engineers and technicians will be happy to help you with the current
-
product
10 MHz to 6 GHz/33 GHz LAN Power Sensor
U2049XA
Wide dynamic range (-70 to +20 dBm) for small signal measurements LAN/ Power-Over-Ethernet (PoE) connectivity for long distance remote monitoring (up to 100 meter)TVAC compliant for operation in vacuum Best-in-class long term drift performance Internal zero and automatic calibration saves time and reduces measurement uncertainty Easy measurement start-up with new intuitive BenchVue software
-
product
Waterproof and Dustproof Portable pH Meter
CyberScan pH 300
Multi-Point Push-button Calibration (up to 5/6 points) with Auto-Buffer Recognition - choice of USA, NIST or DIN buffer standards for quick calibration with no calibration mistakes
-
product
Waterproof Portable pH Meter
CyberScan pH 310
Multi-Point Push-button Calibration (up to 5/6 points) with Auto-Buffer Recognition - choice of USA, NIST or DIN buffer standards for quick calibration with no calibration mistakes
-
product
VXG Vector Signal Generator
M9484C
The M9484C VXG is the industry’s first vector signal generator capable of generating signals up to 54 GHz with 2.5 GHz of modulation bandwidth per channel. The VXG vector signal generator helps you deliver the next frontier of wireless technology such as 5G and satellite communications with a fully integrated, calibrated, and synchronized solution.
-
product
Thermal Voltage Converter
1395B
The 1395B TVC. Has better thermal stability than it's predecessor. Measuring ac voltages between 20 Hz and 100 MHz with increased accuracy and reliability. The 1395B can be used as a primary ac voltage standard and/or standard for the calibration of ac calibrators and voltmeters.
-
product
UV Analyzers
Model UV6
The Model UV6 Analyzers are a family of on-line sampling analyzers that use UV absorption to perform an analysis. The analyzers are configured to perform analysis over a wide range of values for each parameter measured, Nitrate, Color, or the correlation at 254 nm wavelength for COD, BOD or TOC. The UV6 Analyzers are easy to start up and use, simply connect the sample, waste and cleaning solution/reagent lines and then power up the Factory Calibrated analyzer. Wall mounting hardware is standard but an optional benchtop stand with reagent holder is also available. Accessing information or customizing an analysis routine are easily accomplished with the simple, user friendly menu structure and touch screen interface.
-
product
Acoustic Calibrator
CAL250
The Larson Davis Model CAL250 is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
product
ACCUplace Grid Indexing Pattern
AP-G Series
Ensuring precise motion and positional accuracy is critical for a number of video analysis systems and automated measuring instruments. The AP-G series is ideally suited for calibrating such elements, in addition to its uses in determining stage squareness, and travel distance image analysis and visual inspection systems where precise motion must be calibrated and measured. All AP-G targets have number/letter indexed columns and rows for easy calibration and are offered on four standard materials; Glass (CG) Opal (OP) Photopaper (RM) and Film (TM).
-
product
Waterproof pH Tester
pH54
The Milwaukee Waterproof pH54 Tester is one of our most accurate low cost, rugged and reliable pH testers in the market featuring the ability to easily replace the probe providing for years of carefree use. It's simple 2 point manual calibration is simple-to-use. Ideal for use in aquariums, hydroponics, horticulture, education and many other applications.
-
product
Sound Level Meters
PeakTech Prüf- und Messtechnik GmbH
This digital sound level meter with LCD display and function symbols offers manual range selection in 2 measuring ranges. The fast / slow switching as well as the measured value and maximum value holding function and the internal circuit for checking the calibration (94 dB) emphasize the versatility of this device.
-
product
Power Meters and Calibration Cells
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
product
Temperature Calibration Software v5.1
MET/TEMP II
MET/TEMP II software allows you to easily automate the calibration of a wide range of temperature sensors. It provides a comprehensive temperature calibration solution that allows you to test large quantities of sensors, calculate characterization coefficients, and print calibration reports. You can standardize comparison or fixed point calibrations and use multiple temperature sources or references in one test.