Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Coaxial Termination, DC to 26.5 GHz
909D
The Keysight 909D is a precision, low-reflection dc to 26.5 GHz load for terminating a 50-ohm coaxial system in its characteristic impedance. It is intended for use as a calibration standard.
-
product
MP field sources calibration set
The MP field source calibration set is used to measure electric or magnetic fields in a frequency range up to 3 GHz. RF fields or transient fields can be measured. The MP field source calibration set is used to check fields of the Langer EMV-Technik GmbH field sources, fields of TEM cells and IC striplines.
-
product
Calibrator for Vibration Transducers
HD2060
Hand-held calibrator for vibration chains with frequency 15.915 Hz and levels 1 m/s² and 0.1 g, and frequency 159.155 Hz and levels 10 m/s² and 1 g. With LCD display.
-
product
Airborne Gravimeter
GT-2A
The very large dynamic range provides high precision data even in turbulent flying conditions; data is acquired through short periods of saturation in extreme turbulence by the automatic application of a reduced order Kalman filter, enabling platform misalignment to be computed and hence controlled; the automatic calibration program computes accelerometer scale factors and errors in perpendicularity between the accelerometer sensitive axis and the platform surface. The GT-2A installation in a fixed wing aircraft is shown in Fig 1 (courtesy of Excalibur).
-
product
Handheld Water Quality Meters
LAQUA WQ-330-K
Triple channel. Large colour graphic LCD screen (70 x 52 mm) with backlight. Built-in foldable meter stand. IP67 waterproof and dustproof. Battery and USB powered. Eco-friendly, shock-proof, scratch-resistant, and non-slip. Built-in sensor holders. Efficient sensor locking mechanism. Sensor's LED light as reading stability indicator. No sensor adapter needed for attaching multiple sensors together. Compatible with conventional electrodes having BNC and phono connectors and long cables. Sensor status indicator. Temperature sensor indicator. °C & °F temperature units. Sample ID setting. Detailed calibration data. Auto stable, Auto hold, and Real time measurement modes. Customizable meter kit - up to 35 meter-sensor kit combinations. Hands-free testing. Ergonomic design. Multi-language options. Versatile channel and adaptive display. Up to 3 simultaneous calibrations and measurements. Automatic sensor recognition function. Data transfer via USB or wireless communication. Printer communication. 3 years meter warranty.
-
product
Oscilloscope, Calibrated, 2 Channel, 100 MHz, 1 GSPS, 25 kpts, 3.5 ns
72-8710A CAL
The 72-8710A CAL from Tenma is a digital storage oscilloscope with 100MHz bandwidth, 2 analogue channels. The digital storage oscilloscope provides a complete set of trigger modes including edge, pulse, alternate and storage modes including set-up, wave, bitmap. It has a 7 inches wide screen LCD display and supports plug and play USB storage device. Communication with and remote control of computer through the USB device.
-
product
Torque Meter
TorqueMate® PTT-Series
The PTT torque meter makes ISO 9001 documentation faster and easier. As an advanced torque controlling, monitoring and documentation solution, the torque analyzer enables operators and engineers to ensure product quality, safety and reliability promptly in a variety of manufacturing environments. The portable torque meters are designed for measuring torque, torque calibration, joint testing, auditing or force and load measurement.
-
product
4-in-1 OSLT Calibration Kit, DC to 50 GHz, 2.4 mm (m)
CK564A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
CPCI BUS Interface Card
Cpci301 MIL-STD-1553
MIL-STD-1553 A, B & McAir MULTI PROTOCOLS Simulator / Analyzer / Tester CPCI BUS Interface Card - The CPCI301 can be used for Validation Testing, Production Testing, full bus simulation and monitoring, as a general purpose 1553 interface or a stand alone bus Analyzer. For precise message scheduling and measurements, the Major and minor frame times are independent of message sequences or retransmissions on errors and the start of all command messages are independent of message length, response time or length of response. Message timing is calibrated and RT responses have low jitter.
-
product
Spectrometers
Instrument Systems Optische Messtechnik GmbH
Optical spectrometers analyze the spectral characteristics of light radiation. Adding optical probes and absolute calibration turns this type of measurement system into a spectroradiometer. Since software is used to calculate all radiometric, photometric and colorimetric quantities from spectral data, the quality and precision of the spectrometer is extremely important. This is why Instrument Systems is dedicating most of its research and development work to this field in order to be positioned at the leading edge of technology.
-
product
Sound Level Calibrator
511E
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
product
Measurement, Communications & Testing
Process & Analytical Instruments division of AMETEK
Measurement Communications & Testing provides the design, integration and installation of critical communication systems, workflow, life-safety solutions and calibration instruments for temperature, pressure and process control. It also is a leader in level measurement devices, continuous position sensors, hardness testers, force measurement devices and retractable cord reels. In addition, it offers a line of weathering test instrumentation along with laboratory and outdoor testing services.
-
product
Trihedral Corner Reflectors
TCR Series
Precision radar cross section measurements demand precision calibration targets like the TCR Series trihedral corner reflectors. Manufactured to close mechanical tolerances, TRC trihedrals provide reliable and repeatable calibration standards over a wide frequency range through 100 GHz. Surface flatness and perpendicularity are maintained to 1/100 of a wavelength to insure close agreement with theoretical performance.
-
product
Surface Resistance Meter Kit - Test Anti-Static, Static Dissipative and Conductive Surfaces
PRS-812RM
- Surface Resistance Tester from 0.10 Ω to 1 Teraohm- Constant Voltages 10 volts and 100 volts- Automatic Electrification Period- Determines if a surface is Dissipative, Conductive, or Insulative- Measures resistance point-to-point(Rtt) and resistance to ground (Rtg)- Measures resistance of ESD Flooring, ESD Worksurfaces and Packaging- Conforms to all ESD Association Standards for Resistive Characterization- Includes 2 each Surface Resistance Probes- Packaged in a hard shell Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument
-
product
Retroreflector
10767A
The Keysight 10767A Linear Retroreflector is one component in a family of measurement optics that tailor interferometer systems for the physical layout and measurement requirements of each application. When configured with appropriate Keysight5530 Laser Calibration System components, 10767A becomes part of a precise positioning system that improves product quality, increases yields, and facilitates the manufacture of precision products.
-
product
Turning Mirror
10769A
The 10769A is ideal for use in laser measurement and calibration applications. In the calibration of slant bed lathes, for example, the beam steering mirror deflects the beam from the laser head upward, through the interferometer, along the lathe's cross slide. One or more mirrors can also create a path from a laser head to an interferometer located in an otherwise inaccessible position, as in the case of a milling machine with a table that moves in only one axis.
-
product
pH 100 Portable pH Meter
The new addition to the Environmental Express Oakton product line features updates to measuring water quality easier and faster. The larger display is 2.75 in. by 2.0 in. for better viewing angle, and has indicators for battery life, stability, and calibration. It also shows both the parameter and temperature measurements at the same time. The pH 100 meter measures pH, mV, ORP, and temperature. The built-in microprocessor chip enables advanced functions, such as auto calibration, auto temperature compensation, parameter setting, self-diagnosis, auto power-off, and low-battery reminders. The meter uses advanced digital processing technology, intelligently improving the response time and accuracy of your measurements. Stable reading and auto lock display modes are available.
-
product
Blackbody System
IR-518/301
Infrared Systems Development Corp.
The IR-518 Radiation Source provides an accurate, stable source of infrared radiation of known flux and spectral distribution. It can be used as a standard radiation source for the calibration of other laboratory sources, detectors, or other infrared devices requiring calibration against a standard.
-
product
Reference Magnets
Series MT
The reasonably priced WUNTRONIC standard reference magnets offer the possibility in a simple way of being able to calibrate or to check magnet measuring instruments like Gauss Meter/Tesla Meter with the respectively accompanying probes in a defined magnetic field.
-
product
Calibration Services
Edgetech Instruments Inc. has the ability to calibrate any hygrometer (Edgetech Instruments or other manufacturers)Edgetech Instruments performs NIST traceable calibrations and is compliant with ANSI/NCSL Z540-1 and ISO 9001Calibration capabilities include 0-95%RH, dew points down to -75C, traces of oxygen to 10ppm
-
product
DC Source/Calibrators
Our DC Source/Calibrators are designed for a typical applications such as the design, check and calibration of high speed, high resolution A/D converters; design and certification of high speed data logging and process control systems; calibration of digital voltmeters and multimeters; as an “IMBEDDED STANDARD” and/or simulator; design, testing, simulation and certification of thermocouples, strain gages and transducer instrumentation.
-
product
Precision Capacitance Meter
TH2638A
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
product
Temperature Sensor Module
A low cost solution for non-contact temperature measurements. The sensor is integrated with signal conditioning that reliably produces a calibrated linear digital output in a plug-and-play package having many options. Programmable outputs and flexible power requirements yield a turnkey solution for medical, consumer, commercial and industrial applications.
-
product
Open-Short-Load RF calibration kits
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
product
Light Sources
There are many low cost artificial light sources used for illumination or for industrial applications: tungsten or halogen bulbs, fluorescent lamps, LED lamps etc. Some of these sources have regulated intensity of emitted light. However, there very few calibrated light sources of precisely known parameters. A light source can be considered as calibrated when its user can precisely regulate its photometric/radiometric parameters like luminance (or illuminance), radiance (or irradiance) at defined spectrum of interest. Such light sources are needed in many applications among them, in systems for testing night vision devices, VIS-NIR cameras and SWIR imagers. Inframet offers a series of calibrated light sources that can be divides into three groups:
-
product
System Integration Services
Systems integration services to meet a wide variety of industrial needs. It includes the following key expertise: Desktop, Embedded Simulation and Real-time system, Data Acquisition and Report generation/extraction, Factory automation, Testing, Control and Monitoring system, Vision inspection, Equipment calibration, Special purpose machine, and many more.
-
product
Calibration Baths
Calibration baths are electronic controllers which automatically, quickly and with the help of a liquid, supply a temperature. Due to the high reliability and exceptional homogeneity in the measuring chamber, calibration baths are particularly suitable as a factory/working standard for the automatic testing and/or calibration of the widest range of temperature probes - independent of diameter. A special micro calibration bath design enables on-site applications.
-
product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
product
Automatic Calibration Module
ACM2509
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
product
Insulation & Multifunction Tester (LCD Display)
4102 MF
Standard Electric Works Co., Ltd
● Measures Insulation Resistance, voltage (AC-DC) measurements● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● MOV and Gas Arrester Testing.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.