Insulation Test
Check of a materials ability to prevent or reduce transmission.
See Also: Impulse Winding Testers
-
Product
AC Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
High-voltage Dividers (High Potential Divider) are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they are used to measure alternating voltage (AC), direct voltage (DC), lightning impulse voltage (LI), and switching impulse voltage (SI) systems. High-voltage dividers by HIGHVOLT comply with the relevant IEC standards. The systems are available for both indoor and outdoor use.
-
Product
Insulation Tester
CENTER 365
-
Insulation Test Range Up To 20GΩ, Test Voltages Of 50V, 100V, 250V, 500V and 1000V For Insulation Test, >1mA Short-Circuit Test Current For Insulation Test, Live Circuit Detection
-
Product
VLF Insulation Testing
-
VLF testing uses very low frequencies as part of an AC cable maintenance routine. VLF testers are smaller and more practical than AC testers but output the same amount of power as a 50 Hz mains device. This combination of size and power makes Very Low Frequency cable testing perfect for testing longer sections of cable and apparatus
-
Product
Manual PAT Testers
-
If you are looking for a manual PAT tester with a pass fail reading or a PAT tester with readings we have a solution for you. Carry out mains supply checks, IEC lead tests, Earth continuity tests at 200mA, Insulation resistance tests to 250V and 500V, and more with these popular testers. All of our manual PAT testers are available as kits to help you streamline the way you work.
-
Product
Parallel 8-channel Hipot Tester
TH9010
-
Changzhou Tonghui Electronic Co., Ltd.
8-channel parallel output of withstand voltage, and each channel is non-interfering ■ Output: AC: 5kV/10mA; DC: 6kV/5mA ■ Insulation resistance test voltage: 0.10kV -1.00kV
-
Product
Oil Breakdown Voltage Tester
DPA 75 C
-
Insulating oil testing with the BAUR DPA 75C. The BAUR DPA 75C oil tester developed especially for mobile use in the field is one of its kind in the market due to its functionality and excellent user benefits in comparison to the costs. The BAUR DPA 75C delivers clear and reliable measurement results.
-
Product
Transformer Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
Your product description goes here.
-
Product
Digital 5KV High Voltage Insulation Tester
Model KM 6305IN
-
Kusam Electrical Industries Limited
• Microprocessor-controlled.• Tests insulation resistance up to 10 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V.• AC / DC Voltmeter.• Short-circuit current up to 5mA• PI (Polarization Index) indication.• DAR (Dielectric Absorption Ratio) indication.• Auto-ranging on all insulation ranges.
-
Product
Multifunction Tester
M70
-
M70 is a mobile device dedicated to measuring Insulation resistance with test voltage up to 1000VDC and Continuity of protective and equipotential conductors with current of 200mA in private and industrial electric installations.
-
Product
AC Insulation Testing
-
AC insulation tests are a popular response to the increasingly demanding industrial, power and domestic marketplaces. Insulation materials have had to become more efficient to keep up with demand; more efficient equipment requires less insulation material to meet the minimum acceptable value of insulation resistance. In turn, cables have become smaller and lighter. However, under certain higher stress testing conditions such as DC testing, cables like Crossed Linked Polyethylene (XLPE) can quickly degrade.
-
Product
Oil Breakdown Voltage Tester
DTA 100 C
-
Insulating oil testing with the BAUR DTA 100 C. The BAUR DTA 100 C oil tester is designed for continuous operation in the laboratory and is characterised by the combination of extraordinary features. As a high-performance device with a test voltage up to 100 kV, with clear breakdown detection and absolutely reliable measurement results even across several measurement sequences, the BAUR DTA 100 C is the leading testing device for users in the electricity and other industries and in testing institutes.
-
Product
HV Test System up to 20000 Volt
Test System
Insulated test booth with large space for test items. 2 banana sockets for AC connection and 4 banana sockets for the DC connection of the DUTs. IC’s are tested in a long-term test. These are checked in an oil bath so that there are no air gaps to reduce the insulation. Maximum voltage 20 kV. Therefore, insulation tests must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.
-
Product
Oil Breakdown Voltage Tester
DTL C
-
Insulating oil testing with the BAUR DTL C. The established analysis and diagnostic testing of insulating oils with the BAUR DTL C deliver valuable findings in scientific work, research and development. Extensive knowledge on the current state of insulating materials is gaining importance even for the mains network operator. The BAUR DTL C offers the latest and most precise information for efficient oil management in plants in the electricity and other industries.
-
Product
Hybrid Wound Component EST Scanner
19035
-
Chroma Systems Solutions, Inc.
The quality verification test items for Wound Components consist of AC/DC Hipot tests and Insulation Resistance (IR) tests. Chroma integrates the above tests into the Hybrid 19035 Wound Component EST Scanner series to perform safety tests for motor, transformer, and heater related wound products. The wound component manufacturers performing quality verification testing will not only have reliable quality, but also can control product quality efficiently.
-
Product
Digital (1kV up) H.V. Insulation Tester
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.
-
Product
Impulse Voltage Generator
SKS-255I
-
Shanghai Sanki Electronic Industries Co., Ltd.
The impulse voltage generator SKS-255I is manufactured in accordance with the IEC60255-5 "Insulation Test of Electrical Relays" promulgated by the International Electrotechnical Commission. It measures the insulation coordination between relays and protection devices and performs impulse voltage tests.
-
Product
Digital (1kV up) H.V. Insulation Testers
6212A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bargraph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present(>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.
-
Product
DC Hipot with Insulation Resistance Tester
297
-
Our Model 297 is a simple-to-use Hipot Tester with the built-in ability to easily test Insulation Resistance and Ground Continuity (Low Current Continuity) in a one-box solution. The 297 is capable of performing Hipot Tests in both AC & DC currents. Make testing simple with common sense security settings. PLC Remote allows you to make Hipot Testing safer with Personal Protective Equipment (PPE).
-
Product
Digital (1kV below) Insulation Tester
2801 IN
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled with advanced safety features.● Three test voltages : 250 / 500 / 1000V.● Displays and sound warning if external voltage present.● Ener-Save™ feature to extend battery life.● Continuous battery monitoring.● Auto ranging / auto-null / auto-off.● Insulation tested at 1mA.● Built-in carry case, test leads in separate pouch.● Real-time barg-raph display of test voltage and voltage decay during discharge.● Audible and visual message displayed if external voltage is present.● Large LCD.● Display can be customized for special orders.● Continuity buzzer.● Show test time duration (up to 99.9s) for easy comparison.● BS 16 edition.
-
Product
Digital H.V. Insulation Tester(5kV)
6304 IN
-
Standard Electric Works Co., Ltd
● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 1.9mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display
-
Product
Insulation Tester
1kV Megohmmeter
-
*Calculations (automatic)*Potential Index and Dielectric Absorption Ratios*Tests Continuity, Resistance and Frequency Measurements*Programmable Alarms*Insulation Test, Resistance, Continuity*Hazardous Voltage Alert (Icon) if voltage is >70 volts 5.) On Board Timer, +1/- 1 sec
-
Product
VLF Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
1. The current, voltage and waveform data are directly obtained from the high voltage side, so the data is accurate.2. It has over-voltage protection function. When the output exceeds the set voltage limit, the instrument will stop for protection, and the action time is less than 20ms.3. It has over-current protection function: it is designed as high-voltage and low-voltage dual protection, and the high-voltage side can carry out accurate shutdown protection according to the set value; when the current on the low-voltage side exceeds the rated current, it will carry out shutdown protection, and the action time is less than 20ms.
-
Product
Insulation Resistance Test Instrument
2681
-
Shenzhen Chuangxin Instruments Co., Ltd.
Insulation Resistance Test Instrument
-
Product
90-300V AC/DC Voltage Tester
1928A
-
Peaceful Thriving Enterprise Co Ltd
*Handy pocket clip.*With cETL Approval.*Bright neon indicator.*Insulated housing and test leads.*Check voltage on 90-300V AC/DC.*Built-in lamp will glow if the circuit is live.
-
Product
Installation Safety Testers
-
PeakTech Prüf- und Messtechnik GmbH
This innovative combination meter for testing electrical installations according to VDE 0100 convinces by its technical performance in the high-end range.With the large 3.5 "TFT color display all important safety checks as the RCD-, Voltage-, Loop-, Low-Ohm, Earth resistance and Insulation tests for annual safety-checks and newly installed systems can safely be carried out by the responsible electrical engineer.Since this new development was designed only according to the latest standards, the required measuring values can be even more convenient stored with an App (iOS / Android) via Bluetooth on the mobile phone, saved to an SD card or, when work is completed, from the internal data memory via USB connection to a PC.
-
Product
Cable & Insulation Testers
-
A cable insulation resistance test is a test that is performed by applying 500 V or more between the conductor and ground and measuring the resulting leakage current. An insulation resistance tester is a test instrument that measures current that leaks through the insulation into ground. Insulation resistance tests can be performed with insulation multi- meters (IMMs) or megohmmeters. Insulation resistance testers are calibrated to display megohms (MΩ) of resistance. A satisfactory insulation resistance measurement should be in millions of ohms.
-
Product
Digital 10kV High Voltage Insulation Tester
4310 IN
-
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
Product
Digital H.V. Insulation Tester(5kV)
6305 IN
-
Standard Electric Works Co., Ltd
● High contrast OLED display● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display
-
Product
Insulation Testers
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Insulation testers test for capacitance and current leakage in system cables, generators and motors, high voltage equipment and switchgears.
-
Product
Digital (1kV up) H.V. Insulation Testers
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.