Insulation Test
Check of a materials ability to prevent or reduce transmission.
See Also: Impulse Winding Testers
-
Product
Oil Breakdown Voltage Tester
DTA 100 C
-
Insulating oil testing with the BAUR DTA 100 C. The BAUR DTA 100 C oil tester is designed for continuous operation in the laboratory and is characterised by the combination of extraordinary features. As a high-performance device with a test voltage up to 100 kV, with clear breakdown detection and absolutely reliable measurement results even across several measurement sequences, the BAUR DTA 100 C is the leading testing device for users in the electricity and other industries and in testing institutes.
-
Product
Digital (1kV up) H.V. Insulation Tester
6212A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bargraph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present(>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.
-
Product
Analog And Digital Insulation Testers
-
High AccuracyRange Selection & Single Person Push Button OperationLCD Back Light Function with Indicator SwitchData Holding Function, Function Icons on DisplayMeasurement of AC Voltage upto 600VACMeasurement of Phase Sequence between (Phase-PhaseVoltage)with LED Indicator Auto Range (Insulation Test)LED Indicator for High VoltageInbuilt Protection Circuit to prevent the harm of reverse voltagesBattery Operated with AC Adaptor3 Ranges of Voltage & Insulation Resistance
-
Product
Real-Time Open Check Hi-Pot Tester
DU3328
-
Delta United Instrument Co., Ltd.
Programmable test voltage in AC: 0.1K~5KV, DC: 0.1K~6KV Programmable cutting current in AC:0.001mA~15mA, DC: 0.001mA~7.5mA 3 in 1 functions, with AC, DC Hi-Pot test, Insulation test. Built in 100 sets memory Arcing detect function 8 ports scanning function Independent 8 channels real-time open check Real-time check function, to ensure your products tested, no more loss test.
-
Product
Cable & Insulation Testers
-
A cable insulation resistance test is a test that is performed by applying 500 V or more between the conductor and ground and measuring the resulting leakage current. An insulation resistance tester is a test instrument that measures current that leaks through the insulation into ground. Insulation resistance tests can be performed with insulation multi- meters (IMMs) or megohmmeters. Insulation resistance testers are calibrated to display megohms (MΩ) of resistance. A satisfactory insulation resistance measurement should be in millions of ohms.
-
Product
Insulation Resistance Tester
WB2681A
-
• Insulation test voltages: DC250V、DC500V、DC1000V • Range of open-circuit voltage: ±10% rated voltage • Testing time: 3~99 seconds or controlled manually
-
Product
Programmable Withstanding Voltage & Insulation Test
LS9923
-
LS9923 programmable withstanding voltage & insulation test system is high-performance testing device special for AC&DC Withstanding Voltage and Insulation Resistance Test, It allows setting the output voltage. The warning value,testing time and some other parameters can be set in the screen.It with a variety of automatic test functions. The testing is quick and high accuracy which is not only applied in the production line but also in the develop research.
-
Product
DC Insulation Testing
-
Diagnostic insulation testing today represents over a hundred years of constant development. When Sydney Evershed pioneered the first insulation tests in the late 19th century, the only measurable values were insulation at 500 volts and a basic continuity check. However, measurement techniques have continuously evolved to keep pace with new insulation technologies. From electronic design and household wiring to generators and power transmission systems, all different kinds of insulation must operate at a safe minimum value.
-
Product
Digital (1kV up) H.V. Insulation Testers
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.
-
Product
VLF Insulation Testing
-
VLF testing uses very low frequencies as part of an AC cable maintenance routine. VLF testers are smaller and more practical than AC testers but output the same amount of power as a 50 Hz mains device. This combination of size and power makes Very Low Frequency cable testing perfect for testing longer sections of cable and apparatus
-
Product
Digital H.V. Insulation Tester(10kV)
6310 IN
-
Standard Electric Works Co., Ltd
● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 20 TΩ● 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on
-
Product
5-50V AC/DC Voltage Tester
1930A
-
Peaceful Thriving Enterprise Co Ltd
*Reinforced casing.*With cETL Approval.*Check voltage on 5-50V AC/DC.*Insulated housing and test leads.*Pocket clip for added convenience.*Built-in LED indicator will glow when voltage is present.
-
Product
DC Hipot with Insulation Resistance Tester
297
-
Our Model 297 is a simple-to-use Hipot Tester with the built-in ability to easily test Insulation Resistance and Ground Continuity (Low Current Continuity) in a one-box solution. The 297 is capable of performing Hipot Tests in both AC & DC currents. Make testing simple with common sense security settings. PLC Remote allows you to make Hipot Testing safer with Personal Protective Equipment (PPE).
-
Product
Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
Insulation is one of the most important constituents of a transformer. Any weakness in the insulation may cause failure of transformer. To ensure the effectiveness of the insulation system of a transformer, it must confirms the dielectric test. But the power frequency withstand test alone can not be adequate to demonstrate the dielectric strength of a transformer.
-
Product
Digital H.V. Insulation Tester(5kV)
6305 IN
-
Standard Electric Works Co., Ltd
● High contrast OLED display● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display
-
Product
EOL Testing of Starter-Generator Units (ISG)
-
Series test rig for starter-generator units (ISG)*High voltage test*Insulation resistance measurement*Temperature sensor control*Short circuit test*EMF test*Performance measurement*Manual loading and contacting
-
Product
Manual PAT Testers
-
If you are looking for a manual PAT tester with a pass fail reading or a PAT tester with readings we have a solution for you. Carry out mains supply checks, IEC lead tests, Earth continuity tests at 200mA, Insulation resistance tests to 250V and 500V, and more with these popular testers. All of our manual PAT testers are available as kits to help you streamline the way you work.
-
Product
Automatic Oil Insulation Test Kit
-
The test kit is fully automatic and has the facility forAuto/Manual selections. The operator simply needs thesample in the test vessel & selects the required test. Testingcan be done as per many international ( IEC & Europeanstandards ) which are programmed into the instrumentmemory . Stand time, Stir times & Rate of rise of appliedvoltage can be selected in Custom Mode also , one setof such selected mode can also be stored in the memory. In addition to the above set can also perform withstand test(proof) tests. In this test the set allows the set voltage to pre-set value & hold for one minute to see if breakdown occurs. The backlit LCD is used for user friendly operationsduring the test process. It also display fault condition messages such as open ground and cover open . All the user selected programmes are chosen through(4x3) key pad.The test results can be printed along with with test type, date, time, breakdown test voltage, averages and deviations. Voltage value can be measured & printed with a resolution of 0.1kV. In reprint option it is possible to have number of printouts for the last test. For each test the readings are recorded and stored in memory.
-
Product
Oil Breakdown Voltage Tester
DTA IL
-
Insulating oil testing with the BAUR DTA IL. The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality.
-
Product
Digital H.V. Insulation Tester(5kV)
6304 IN
-
Standard Electric Works Co., Ltd
● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 1.9mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display
-
Product
Digital (1kV up) H.V. Insulation Testers
6212A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bargraph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present(>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.
-
Product
Digital 5KV High Voltage Insulation Tester
Model KM 6305IN
-
Kusam Electrical Industries Limited
• Microprocessor-controlled.• Tests insulation resistance up to 10 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V.• AC / DC Voltmeter.• Short-circuit current up to 5mA• PI (Polarization Index) indication.• DAR (Dielectric Absorption Ratio) indication.• Auto-ranging on all insulation ranges.
-
Product
Test Points, Tips, Probes, Jumpers and Clips
-
Nickel Plated Steel Alligator Clips. PTFE Insulated Terminals and Test Point Jacks. Circuit Board Test Jacks and Plugs. Color Coded PCB Mount Test Points, Loop Style with Plastic Base for Snap-In Mounting. Surface Mount Test Points on Tape and Reel.
-
Product
90-300V AC/DC Twin-Lead Circuit Tester
1928
-
Peaceful Thriving Enterprise Co Ltd
*Handy pocket clip.*Bright neon indicator.*With UL and cUL Approval.*Insulated housing and test leads.*Check voltage on 90-300V AC/DC.*Built-in lamp will glow if the circuit is live.
-
Product
Installation Testers
-
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
Product
Digital (1kV up) H.V. Insulation Tester
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.
-
Product
Passive Component ATS
-
Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe
-
Product
Insulation & Multifunction Tester (LCD Display)
2788 MF
-
Standard Electric Works Co., Ltd
● Auto-range microprocessor-controlled.● Insulation test voltages : 250V, 500V, 1000V.● Mov / protection devices test.● Gas Arrester function.● Automatic voltmeter AC/DC at Start/Reset.● Test ON-OFF.● Battery test.● Safety voltmeter before each test.● Auto-discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter AC/DC.● Ener-Save™.
-
Product
Insulation Testing
-
Measures the total resistance between any two points separated by electrical insulation.
-
Product
Hybrid Wound Component EST Scanner
19035
-
Chroma Systems Solutions, Inc.
The quality verification test items for Wound Components consist of AC/DC Hipot tests and Insulation Resistance (IR) tests. Chroma integrates the above tests into the Hybrid 19035 Wound Component EST Scanner series to perform safety tests for motor, transformer, and heater related wound products. The wound component manufacturers performing quality verification testing will not only have reliable quality, but also can control product quality efficiently.





























