Insulation Test
Check of a materials ability to prevent or reduce transmission.
See Also: Impulse Winding Testers
-
product
Test Points, Tips, Probes, Jumpers and Clips
Nickel Plated Steel Alligator Clips. PTFE Insulated Terminals and Test Point Jacks. Circuit Board Test Jacks and Plugs. Color Coded PCB Mount Test Points, Loop Style with Plastic Base for Snap-In Mounting. Surface Mount Test Points on Tape and Reel.
-
product
Digital H.V. Insulation Tester(5kV)
6305 IN
Standard Electric Works Co., Ltd
● High contrast OLED display● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display
-
product
Hybrid Wound Component EST Scanner
19035
Chroma Systems Solutions, Inc.
The quality verification test items for Wound Components consist of AC/DC Hipot tests and Insulation Resistance (IR) tests. Chroma integrates the above tests into the Hybrid 19035 Wound Component EST Scanner series to perform safety tests for motor, transformer, and heater related wound products. The wound component manufacturers performing quality verification testing will not only have reliable quality, but also can control product quality efficiently.
-
product
Hipot Testers
Hypot® Series
The Hypot Series sets the standard for safety and efficiency in production line Hipot Testing. Whether your application requires AC Withstand tests, DC Withstand tests, or Insulation Resistance tests, The Hypot Series provides innovations that will allow you to begin achieving best practices for safety and efficiency without the need for an expensive automated test system or connection to a PC. You can even connect the Hypot Series with the HYAMP Series to form a seamless safety compliance system for Hipot and Ground Bond Testing.
-
product
Digital H.V. Insulation Tester(5kV)
6304 IN
Standard Electric Works Co., Ltd
● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 1.9mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display
-
product
Digital 10kV High Voltage Insulation Tester
4310 IN
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
product
HV Test System for Patient Monitors
HV test enclosure for testing medical products (patient monitors). Insulated test booth with large space for DUT.3 different test nests for adapting different devices.Displays from patient monitors are checked. For this, insulation tests and leakage current measurements must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.
-
product
Oil Breakdown Voltage Tester
DTA IL
BAUR Prüf- und Messtechnik GmbH
Insulating oil testing with the BAUR DTA IL. The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality.
-
product
Multifunction Tester
M70
M70 is a mobile device dedicated to measuring Insulation resistance with test voltage up to 1000VDC and Continuity of protective and equipotential conductors with current of 200mA in private and industrial electric installations.
-
product
Impulse Voltage Generator
SKS-255I
Shanghai Sanki Electronic Industries Co., Ltd.
The impulse voltage generator SKS-255I is manufactured in accordance with the IEC60255-5 "Insulation Test of Electrical Relays" promulgated by the International Electrotechnical Commission. It measures the insulation coordination between relays and protection devices and performs impulse voltage tests.
-
product
Digital 5KV High Voltage Insulation Tester
Model KM 6305IN
Kusam Electrical Industries Limited
• Microprocessor-controlled.• Tests insulation resistance up to 10 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V.• AC / DC Voltmeter.• Short-circuit current up to 5mA• PI (Polarization Index) indication.• DAR (Dielectric Absorption Ratio) indication.• Auto-ranging on all insulation ranges.
-
product
Real-Time Open Check Hi-Pot Tester
DU3328
Delta United Instrument Co., Ltd.
Programmable test voltage in AC: 0.1K~5KV, DC: 0.1K~6KV Programmable cutting current in AC:0.001mA~15mA, DC: 0.001mA~7.5mA 3 in 1 functions, with AC, DC Hi-Pot test, Insulation test. Built in 100 sets memory Arcing detect function 8 ports scanning function Independent 8 channels real-time open check Real-time check function, to ensure your products tested, no more loss test.
-
product
Digital (1kV below) Insulation Tester
2801 IN
Standard Electric Works Co., Ltd
● Microprocessor-controlled with advanced safety features.● Three test voltages : 250 / 500 / 1000V.● Displays and sound warning if external voltage present.● Ener-Save™ feature to extend battery life.● Continuous battery monitoring.● Auto ranging / auto-null / auto-off.● Insulation tested at 1mA.● Built-in carry case, test leads in separate pouch.● Real-time barg-raph display of test voltage and voltage decay during discharge.● Audible and visual message displayed if external voltage is present.● Large LCD.● Display can be customized for special orders.● Continuity buzzer.● Show test time duration (up to 99.9s) for easy comparison.● BS 16 edition.
-
product
Insulation Tester
Megohmmeter, 5kV
*Auto Calibration on Start-up*Onboard Battery Charger*Mains Power: 90-260Vac, 45-65 Hz*Hazardous Voltage Warning Icon > 70 volts*Test: Insulation, Voltage & Frequency
-
product
AC DC High Voltage Break Down Tester
RR – AC DC HIPOT TESTERS can perform such precise dielectric test in a cost effective manner without any compromise on safety. Our hipot testers are custom made to suit needs of various industries and product ranges. A Singe tester can be used for conducting both AC and DC Insulation Testing.
-
product
Insulating Transformer Oil Test Set
NMC make Insulating BDV Oil Test Set are used to check the di-electric strength of the transformer oil.
-
product
Digital 5kV High Voltage Insulation Tester
4305 IN
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 1 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
product
HV Test System up to 20000 Volt
Insulated test booth with large space for test items. 2 banana sockets for AC connection and 4 banana sockets for the DC connection of the DUTs. IC’s are tested in a long-term test. These are checked in an oil bath so that there are no air gaps to reduce the insulation. Maximum voltage 20 kV. Therefore, insulation tests must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.
-
product
AC Insulation Testing
AC insulation tests are a popular response to the increasingly demanding industrial, power and domestic marketplaces. Insulation materials have had to become more efficient to keep up with demand; more efficient equipment requires less insulation material to meet the minimum acceptable value of insulation resistance. In turn, cables have become smaller and lighter. However, under certain higher stress testing conditions such as DC testing, cables like Crossed Linked Polyethylene (XLPE) can quickly degrade.
-
product
Oil Breakdown Voltage Tester
DTL C
BAUR Prüf- und Messtechnik GmbH
Insulating oil testing with the BAUR DTL C. The established analysis and diagnostic testing of insulating oils with the BAUR DTL C deliver valuable findings in scientific work, research and development. Extensive knowledge on the current state of insulating materials is gaining importance even for the mains network operator. The BAUR DTL C offers the latest and most precise information for efficient oil management in plants in the electricity and other industries.
-
product
Programmable Withstanding Voltage & Insulation Test
LS9923
LS9923 programmable withstanding voltage & insulation test system is high-performance testing device special for AC&DC Withstanding Voltage and Insulation Resistance Test, It allows setting the output voltage. The warning value,testing time and some other parameters can be set in the screen.It with a variety of automatic test functions. The testing is quick and high accuracy which is not only applied in the production line but also in the develop research.
-
product
VLF Insulation Testing
Weshine Electric Manufacturing Co., Ltd
1. The current, voltage and waveform data are directly obtained from the high voltage side, so the data is accurate.2. It has over-voltage protection function. When the output exceeds the set voltage limit, the instrument will stop for protection, and the action time is less than 20ms.3. It has over-current protection function: it is designed as high-voltage and low-voltage dual protection, and the high-voltage side can carry out accurate shutdown protection according to the set value; when the current on the low-voltage side exceeds the rated current, it will carry out shutdown protection, and the action time is less than 20ms.
-
product
Digital (1kV up) H.V. Insulation Testers
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.
-
product
Insulation Tester
CENTER 365
Insulation Test Range Up To 20GΩ, Test Voltages Of 50V, 100V, 250V, 500V and 1000V For Insulation Test, >1mA Short-Circuit Test Current For Insulation Test, Live Circuit Detection
-
product
Transformer Insulation Testing
The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).
-
product
DC Insulation Testing
Diagnostic insulation testing today represents over a hundred years of constant development. When Sydney Evershed pioneered the first insulation tests in the late 19th century, the only measurable values were insulation at 500 volts and a basic continuity check. However, measurement techniques have continuously evolved to keep pace with new insulation technologies. From electronic design and household wiring to generators and power transmission systems, all different kinds of insulation must operate at a safe minimum value.
-
product
Passive Component ATS
Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe
-
product
Insulation Resistance Tester
WB2681A
• Insulation test voltages: DC250V、DC500V、DC1000V • Range of open-circuit voltage: ±10% rated voltage • Testing time: 3~99 seconds or controlled manually
-
product
Installation Safety Testers
PeakTech Prüf- und Messtechnik GmbH
This innovative combination meter for testing electrical installations according to VDE 0100 convinces by its technical performance in the high-end range.With the large 3.5 "TFT color display all important safety checks as the RCD-, Voltage-, Loop-, Low-Ohm, Earth resistance and Insulation tests for annual safety-checks and newly installed systems can safely be carried out by the responsible electrical engineer.Since this new development was designed only according to the latest standards, the required measuring values can be even more convenient stored with an App (iOS / Android) via Bluetooth on the mobile phone, saved to an SD card or, when work is completed, from the internal data memory via USB connection to a PC.