V.35
-
product
Hot sale Window Tint Meter WTM-1100
WTM-1100
Guangzhou Landtek Instruments Co. Ltd.
Window Tint Meter WTM-1100Applications:Window Tint Meter WTM-1100 is applicable to measure the transmittance or haze of all kinds of transparent, translucent samples withparallel plane.Details:Display:10mm LCDMeasurement Range:0 to 100% Light TransmissionResolution:0.1Accuracy:± 2 %Sample Thickness:Less Than 18mm / 0.7inchLight Source:LEDMeasuring Mode:Single / ContinuousOperating conditions:Temperature: 0 ~ 50 ℃ Humidity: < 90 %Power Supply:4 x 1.5 V AAA Size (UM-4) BatteryDimensions:Unit: 126 x 65 x 27 mm (5.0 x 2.6 x 1.1 inch)Sensor: 125 x 38 x 38 mmWeight:100 g (Not Including Batteries)Accessories:Standard Accessories1. Main Unit2. Carrying Case3. Operation ManualOptional Accessories1. USB, RS-232C data cable with software2. Bluetooth data out put with softwareFor window tint meter price , please feel free to contact Lisa. Thank you!
-
product
Alarms
IP66 Series
Teledyne Gas & Flame Detection
The IP66 Series of Models A-IP66, V-IP66 and AV1-IP66 consist of an audible sounder (A), a visual beacon (V) or a combination of the two (AV1).All of these options come in impact resistant plastic housings that are rated to IP66 for dust and water ingress protection.The visual warning beacon comes in field interchangeable lens colors of amber, blue, clear, green, red, yellow and magenta.
-
product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779014-01
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
product
Micro Coax, Contact, Receiver, 50 GHz
610140108
Primary mating contact 610141108. (May mate with other ITA contacts, as well.) *This contact sold as a patchcord only.Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 30µ" Au over 100µ" NiContact Termination Solder Nut ClampInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC-50GHzVSWR 1.06+0.004 f(GHz)Insertion Loss - .095 x √f(GHz) dBDWV 700 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications Flex 405Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
2kV, 400 MHz High Voltage Differential Probe
HVD3220
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
Bench Power Supply, Single, Adjustable, 2 Output, 0 V, 32 V, 0 A, 5 A
72-8700A
This Bench Power Supply 35V @ 5A max output has a master-slave tracking, constant voltage, constant current function. The main outputs can be connected in parallel or in series. Auto switching between voltage and current operation.
-
product
Voltage Input Device For FieldDAQ
The Voltage Input Device for FieldDAQ measures up to eight ±10 V channels with 24-bit resolution and simultaneous sample rates up to 100 kS/s/ch. Some models can power sensors, such as pressure sensors, with up to 24 V per input channel. This device offers 500 V channel-to-channel isolation, protecting instrumentation from high-transient voltages. Additionally, the device is IP65 and IP67 rated to be dust-proof and water-submersible, can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. It has an integrated network switch for simplified daisy chaining and provides tight synchronization over time sensitive networking (TSN) for distributed data acquisition systems.The Voltage Input Device for FieldDAQ includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Custom Assembly, Packaging and Qualification
DPACI specializes in providing Turn-Key Solutions. We offer comprehensive manufacturing, assembly, qualification, testing, and certification of high reliability EEE components. We have a dedicated, self-contained Class 10,000 clean room with Class 100 laminar flows certified to QML Q (Military) and V (Space) levels to perform all assembly operations from wafer processing to final hermetic package seal
-
product
High-Voltage Dividers & Capacitors
Measurements International Ltd.
300 V to 300 kV, Outputs of 120 Vac, Primary Standard HV Measurements, Loss Measurement Systems, IEEE-488 Interface, Division Accuracy < 20 ppm, Calibration Period 3 to 5 Years.
-
product
AC/DC Clamp Meter
CM4374
• AC/DC Clamp • True RMS • 600/2000 A range • V, A, Hz, Ω, and other extensive measurement parameters • Inrush current • Max/Min/Avg/Peak • Wireless data download to a tablet or smartphone
-
product
Bench Power Supply, Single, Adjustable, Fixed, 3 Output, 0 V, 30 V, 0 A, 10 A
72-7660
Compact, regulated constant voltage power supply for service field, hobby and telecommunication equipment. It provides three different voltage output for different usage.
-
product
COMPUTERIZED AUTOMATIC RELAY TEST SYSTEM
CVRT-S16
CVRT-S8 & S16 are ideal for automatic testing of ELECTRO MECHANICAL AND READ RELAYS (only DC relays) both for static and dynamic characteristics. This system scans at one stroke, all the parameters of the relay as per definition of test procedure. The test sequence can be pre-programmed and stored in the disk. You can select the tests as per your requirement. Can include or exclude the test and you can have several options to match your test definitions. Semi skilled person can be engaged for actual testing, as he need not make any settings and need not interpret the readings. The system conducts the tests and gives PASS / FAIL indication on overall test results. If a printer is connected, each test result will be printed.Test Parameters : -> Coil Resistance.-> PickUp/Pull In /Operating Voltage or Current Linear Ramp Method or Step Method.-> Measure Pickup Contact Gap FBB-LBB V or mA-> DropAway/Drop Out/Release Voltage or Current Linear Ramp Method or Step Method.-> DropAway Contact Gap FFB-LFB V or mA-> % Release Dropaway/Pickup-> Contact Resistance of all contacts both Front and Back contacts.-> Operating Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while Operating @ above-> Release Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while release @ above-> Difference of Operate Time - Release Time.-> Bridging Test or Non Overlap Test.-> Transfer or Traverse Times while Operate and release.-> Operate Time @2nd Set Voltage or Current.-> Release Time @2nd Set Voltage or Current.-> Power Consumption @ Rated Voltage.-> Coil Current @ Rated Voltage at Room Temperature.-> Coil Resistance Corrected to 20deg C.-> Timing Waveform Graph for all active Contacts.
-
product
AC/DC Power Supply 4 W
RAC04-3.3SK/277
AC/DC power supply with 4 W from Recom | input ranges 80 - 308 VAC | output 3.3 V | operates in temperature from -40 to +90 °C | only available on request
-
product
Insulation Resistance Meters
Scientific Mes-Technik Private Ltd
General purpose insulation resistance meterAnalog indicator, High measurement speedTest voltage range: 10 V to 500 VSuitable for Test capacitor insulation testEasy operation
-
product
NIST Calibration for D610-A
D610-A-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Performance AC Power Source, 375 VA, 300 V, 3.25 A
6811C
Maximize your investment with five instruments in one device Increase your productivity with extensive built-in power measurement capabilities Flexible IO: LAN/LXI Core, USB and GPIB Lower your cost of ownership with global support & the longest standard warranty in the industry
-
product
PXI Digital Pattern Instrument
The PXI Digital Pattern Instrument is designed for semiconductor characterization and production test. It provides 32 channels, a voltage range of -2 V to 6 V, a PPMU force voltage range of -2 V to 7 V, up to a 200 Mb/s data rate, and a clock generation rate up to 160 MHz. The module includes Digital Pattern Editor software as well as debugging tools like shmoo, digital scope, viewers for history RAM, pin states, and system status.
-
product
16-bit, 100KHz, 16SE/8DIFF A/D Inputs; 4 14-bit, 30KHz D/A Outputs, 4 24V Digital I/O, All Isolated
CPCI-3120-16-4
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
product
Loop-Powered Digital Panel Meter
88-PRO
The 88-PRO Process Meter may be connected directly to a 4-20 mA, 10-50 mA or 1-5 mA current loop, with no need for additional power to the meter. This is because the meter is powered directly by the current loop, developing a maximum voltage drop of 2.5 V.
-
product
High Voltage Pulse Attenuators
Barth High Voltage Pulse Attenuators are matched impedance coaxial attenuators for use primarily in pulsed 50 ohm systems, or where occasional transients would damage ordinary units. The attenuator design closely matches the impedance around each resistor, to that resistor. These attenuators feature an input impedance very close to 50 ohms, with characteristics as good or better than most microwave attenuators. These units are ideal for use in nuclear and high energy experiments. Extensive testing during manufacturing insures very high reliability for single-shot experiments. A voltage coefficient of the resistive film of less than .0001 %/V allows low voltage calibration of most systems.
-
product
Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit
72-1015 CAL DU
The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
product
PXI/PXIe High Voltage Multiplexer, Hex 7-Channel, 1-Pole
42-321-103-HI
The 40-321-103-HI (PXI) and 42-321-103-HI (PXIe) are hex 7-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
Programmable Step Attenuator, DC to 40 GHz, 0 to 90 dB, 10 dB Steps
84906L
The Keysight 84906L programmable step attenuator offers coaxial measurements to 40 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life greater than 5 million switching cycles per section) and an attenuation range of 0 to 90 dB in 10-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with with only 2.4 dB of loss at 40 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
product
16 Relay Output PCIe Board, 8 Isolated Digital Input Channels, 24V
APCIE-2200-16-8
8 electromechanical relays with change-over contacts The PCI-Express 16 relay board APCIe-2200-16-8 has 16 relay output channels and 8 isolated digital inputs, 24 V. 7 inputs are interruptible. The board is especially suited for applications like industrial I/O control, signal switching, alarm monitoring, as interface to machines, for the ON/OFF monitoring of motors, lights etc. in the harsh industrial environment.
-
product
3-Slot Data Acquisition Mainframe With GPIB, Three 20-Channel Multiplexer Modules, And BenchVue DAQ Software
DAQ973MBX
The DAQ973MBX Best Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, three 20-channel DAQM901A multiplexer modules, and a BV0006B BenchVue DAQ software with a KeysightCare software support subscription. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2-and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning measures thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance36-month node-lock BV0006B BenchVue DAQ software license with KeysightCare software support subscription
-
product
Multifunctional Meter
AEM-DR
Provide high accuracy measurement, display and remote communication of single phase & three phase parameters (V, A, P, Q, S, PF, Hz, Kwh). Multicircuit design and relay output modular expansion design decrease the overall cost and make the functionality more flexible. All monitored data is available via a RS485 serial , for the needs in energy management, alarming, and remote controlling. Embedded flash memory for Data-Logging can avoid any data missing once the communication is interrupted. Moreover, its ultra compact size DIN-rail mounting makes itself mountable in virtually any panel, enclosure or indoor Cabinet.
-
product
Adjustable Isolating Transformers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).
-
product
3-Slot Data Acquisition Mainframe With Three 20-Channel Multiplexer Modules
DAQ970MB
The DAQ970MB Good Multiplexer Bundle offer includes a DAQ970A three-slot data acquisition mainframe and three 20-channel DAQM901A multiplexer modules. This bundle provides the following:3-slot mainframe with USB and LAN6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
product
NI-9209 , ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
785042-01
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
product
Dual Channel Driver Card
40461
Two channels of 8 to 10 MHz drivers (25 V amplitude). The output voltage range is ±25V, with independent high and low voltage settings. The inputs to the Card are optically isolated. The card also contains voltage and current sense capability, which allows muxing of the current or voltage output measurements from all the Driver Channels in the system to a single DVM. The card allows independent programming of the rise and fall time of each channel as low as one nanosecond increments.





























