Immunity
See Also: Immunity Test, Radiated Immunity, EMC
-
Product
Anechoic Chamber
EMC-3
-
A 3 meter test range ensuring fully compliant Emission and Immunity testing. Ferrite and hybrid pyramidal absorbers are combined in a unique pattern within a SmartShield high performance chamber. Operating at a 3m test distance, this chamber is compliant to CISPR-16 with a measurement zone diameter of 1-2 meters.
-
Product
Conducted Immunity Test Systems
-
Conducted Immunity System (CIS) to Test According to IEC 61000-4-6. The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.
-
Product
Transient Immunity Tester
KES7700
-
Transient Immunity Tester KES7700 Series are transient surge tester that utilizes a compact unit system. A surge generator circuit is installed for each pulse unit as the tester meets the requirement of ISO7637-2, ISO7637-3, ISO16750-2, JASO D001, SAEJ1113, and other standards. The KES7700 Series meets a broad range of independent automobile manufacturer standards as well.
-
Product
RF swept immunity package
EMiSweep
-
This is a flexible Windows immunity package which provides the utilmate flexible Graphical User interface. Other visual aids provides a swept as well as spot frequency assessment.
-
Product
15W - Single Output / Multiple Output
PXB Series
-
*Industry Standard 1" x 1" Footprint*9-18, 9-36, 18-36, 18-75, 36-75 Vdc Inputs*3.3, 5, 12, 15, ±5, ±12, ±15 Vdc Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
Product
20W to 30W - Single Output / Multiple Output
PXE Series
-
*Industry Standard 2" x 1.6" Footprint*9-18, 9-36, 18-36, 18-75, 36-75 Vdc Inputs*3.3, 5, 12, 15, ±5, ±12, ±15 Vdc Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
Product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
-
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
Product
TDK Software
-
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab
-
Product
Resistors
-
*High Accuracy.*Low Temperature Coefficients.*High Immunity from Environmental Effects.*High Reliability -From 0.01 Ω to 10 MΩ.*By Spetcial orders Only.
-
Product
Electromagnetic Immunity Scanner
SmartScan BASIC
-
The BASIC is manually operated system for performing susceptibility scanning at the system level with minimal data storage capability. This system includes:1. Up to 8kV (optional. 4kV base) pulse generator for ESD susceptibility testing- Camera and camera shutter to take DUT picture and failing spots- Control computer2. Up to 8kV Probe Sets:- 1mm Hx/y Field Probe- 5mm Hx/y Field Probe- D=8mm Hz Field Probe- D=8mm Ez Field Probe- Contact API for custom design probes3. Manual input of testing location and failing condition over the DUT to be included in final report.
-
Product
14W to 60W - Single Output
ZPSA Series
-
*Wide Range AC Input*Low Profile, Industry Standard Footprint*Global Safety Agency Compliance*EN61000-4 Immunity
-
Product
Turned Multiple Dipole Antenna
MODP2080
-
Antenna for Radiation Immunity Test on Car Max. Input Power : 12kW & High Erectric Field at = 4 : 100V/m Contolable the Height/Deviation by own unique Stand Patent Information.
-
Product
IEC61000-4-4 4.8KV Electrical Fast Transient Immunity Generator
EFT-404BX
-
Shenzhen Chuangxin Instruments Co., Ltd.
EFT-404BX Impulse Generator is fully met requirements of the standards IEC61000-4-4 and GB/T17616.4.
-
Product
Immunity DC
PGA 1240
-
The power generator PGA 1240 is suitable for EMC testing in accordance with standard IEC / EN 61000-4-16 in the frequency range from DC to 300 kHz.
-
Product
EOS Tester
KT-200SG
-
This test instrument stands for the EMI(Electro Magnetic Immunity) ability test to the electric devices, electronic circuit boards & electric equipments. Recently this instrument is widly used in many companies in Korea & other countries to test the immunity to thier products-power supply, drive PCBs, communication systems, LCD display panels whether they are safe or not against the impulse & noise.All for the purpose, of this object, it generates 4 ~ 5 kinds of different impulse test waveforms.Output test voltage level : 5 ~ 200 V ImpulseOutput voltage polarity : Positive, NegativeType of waveforms
-
Product
DC Immune Current Transformer
DCT 108
-
SHANGHAI POWOO INDUSTRY CO., LTD
- Accurate DC measurement; comply to IEC 1036 and IEC 62053; - suitable for a wide range of current (from 1.5A to 100A); - linear output current, high precision; - compact, delicate appearance.
-
Product
Anti-Tamper Sub-Assemby (DC Immune CTs + Potential Transformer)
-
SHANGHAI POWOO INDUSTRY CO., LTD
ATS can provide double loop current sampling and power supply for measuring unit of static meter. When load voltage, static meter can in normal condition without single-channel current.