Filter Results By:
Products
Applications
Manufacturers
Scattering
a propagating wave or moving particle's linear trajectory, interrupted by non-uniformity in the medium they move through.
-
product
Modular SEC system
SC2000
The new Postnova SC2000 Modular SEC system offers unrivalled flexibility in Advanced SEC/GPC analysis. It is the first truly modular multi-detector SEC system available allowing flexible access to a wide range of applications. The system incorporates state-of-the-art detection technologies including light scattering (MALS > multi-angle light scattering) for absolute molecular weight and Viscosity detection for structural and conformational data. Many other detector and accessory options and combinations are available to build a system uniquely tailored to your application requirements, with the benefit of modularity to allow easy future expansion. In addition, the SC2000 can be further expanded to include FFF modules to widen the application range and allow both SEC and FFF separations to be carried out on the same sample within one instrument platform.
-
product
Multi-Angle Light Scattering Detectors
Since the 1990s Postnova has been a leading innovator and developer of special advanced online Light Scattering solutions for coupling with chromatographic separation systems. The first model was the PD2000 - Static Light Scattering detector for coupling with Asymmetric Flow FFF. Later on the models PN3020 SLS and PN3070 MALS have been launched. Based on these over two decades of practical experience, Postnova has collected a unique competence in the area of Laser Light Scattering and has developed the unique PN3621 MALS - Multi-Angle Light Scattering detector series. The model PN3621 MALS is a completely new type of high performance MALS detector system with a unique range of specifications.
-
product
Benchtop Small Angle X-ray Scattering (SAXS) Instrument
NANOPIX mini
Non-destructive measurement of particle size and size distribution.Rigaku NANOPIX mini is the world’s first benchtop small angle X-ray scattering (SAXS) system that is engineered to deliver automatic nanoparticle size distribution analysis for both quality control (QC) and research and development (R&D) applications. Nanoparticle size, size distribution, and particle shape are the key pieces of information obtained from SAXS. Samples may range from solutions, suspensions or slurries to solid plastics, rubbers or polymers.
-
product
Solar Cell Simulation
Setfos
Easily calculate the short circuit current, open circuit voltage Voc and fill factor with Setfos. Tweak the layer stack and add light scattering layers for enhanced absorption. Optimize for AM1.5 or specific wavelength bandsElectrical IV curvesCurve fitting & parameter extractionAC simulation and transient experiments like photo-CELIVAdvanced device physics: SRH-recombination, excitons, ... Design anti-reflection coatings or transparent cells
-
product
Turbidity Sensor
The Aanderaa Turbidity sensors detects infra-red light scattered by particles suspended in water.
-
product
Laser Particle Size Analyzer
Easysizer20
Zhengzhou Nanbei Instrument Equipment Co. Ltd
sysizer20 is the latest product of OMEC in Year 2006 and is highly automated, all the process can be done automatically after setting up initial parameters. Multiple sample feeding systems are available to meet your requirements. Applications:Measure the particle size distribution of powder or latex Principle:Use the principle of laser light scattering to determine particle size distribution.
-
product
CG-MALS
Calypso II
Label-free, immobilization-free characterization of protein-protein and other macromolecular interactions with composition-gradient multi-angle light scattering.
-
product
Turbidity Meter
TF16-N
The TF16-N is a high precision turbidity meter for installation into pipelines measuring scattered and unscattered light at two independent angles in various liquid process streams. The ratio of scattered to un-scattered light can then be correlated.
-
product
TSS Meter
LD-LTSS-A10
TSS meterLD-LTSS-A10is a tabletop meter with a dual-beam infrared scattered light photometerdetection system for enhanced stability. Built-in self-diagnosis function to ensure dataaccuracy. Optional cleaning brush for automate cleansing function to reduce the sensormaintenance.
-
product
EMORAL LiDARESA Mobile Raman
The EMORAL LIDAR observations at the PolWET site in Rzecin, Poland, on 10 June 2019. The scattering ratio (top), quasi-particle depolarization ratio (middle), and backscatter colour ratio (bottom) derived at 532 nm with 30 m spatial and 30 s temporal resolutions
-
product
Water Treatment Plant Analyzer
Aqualog
Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.
-
product
Profiling Current Meter and Wave
SeaGuardII DCP Wave
The SeaGuardII DCP Wave is a 600kHz Doppler Current Profiler able to measure directional wave parameters and currents from a bottom mounted installation.The Acoustic Wave software 5759 used by the DCPS implements unique features to improve the wave measurement accuracy by optimizing the signal to noise ratio.Maximum deployment depth is 40m in normal scatter conditions. The Profiling Current Meter and Waveis available as a self-recording instrument. It can be easily integrated into a real-time system offering reliable two-way communication.
-
product
Deep Submersible Particle Size Analyzer
LISST-Deep
The LISST-DEEP instrument obtains in-situmeasurements of particle size distribution,optical transmission, and the opticalvolume scattering function (VSF). Using ared 670nm diode laser and a customsilicon detector, small-angle scatteringfrom suspended particles is sensed at 32specific log-spaced angle ranges. Thismeasurement is post-processed to obtainsediment size distribution, volumeconcentration, optical transmission, andVSF. The electronics and opticalconfiguration in the LISST-DEEP are verysimilar to Sequoia’s workhorse, the LISST-100X. However, because of the extremedifficulty associated with keepingalignment under high pressure, the LISSTDEEPhardware design is radically differentfrom the LISST-100X. This allows theLISST-DEEP to be deployed down to 3000m and obtain reliable measurements ofthe in situ particle size distribution andvolume concentration in waters withoptical transmission up to 98.5%.
-
product
Turbidity Sensors
Turbidity sensors measure the amount of light that is scattered by the suspended solids in water. As the amount of total suspended solids (TSS) in water increases, the water's turbidity level (and cloudiness or haziness) increases. Turbidity sensors are used in river and stream gaging, wastewater and effluent measurements, control instrumentation for settling ponds, sediment transport research, and laboratory measurements.
-
product
Viscometer
ViscoStar III
A highly sensitive, on-line differential viscometer used in conjunction with SEC-MALS to determine the size and conformation of all types of biopolymers, synthetic polymers and even proteins and peptides. The ViscoStar III incorporates multiple novel technologies to provide the highest sensitivity, stability and solvent compatibility of any available viscometer for GPC. Its ease-of-use and serviceability make it the perfect companion for Wyatt's DAWN HELEOS II light scattering and Optilab T-rEX refractive index detectors.
-
product
UltraScan VIS Spectrophotometer
Hunter Associates Laboratory, Inc.
The UltraScan VIS easily measures both reflected and transmitted color as well as transmission haze and meets CIE, ASTM and USP guidelines for accurate color measurement. UltraScan VIS uses diffuse/8° geometry with automated specular component inclusion/exclusion. For transmission measurement, the use of a robust CIE-conforming sphere instrument (TTRAN Total Transmission mode) effectively negates the effects of minor scattering typically found in transparent samples.
-
product
Vector Network Analyzer
SIGLENT Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, with 2/4-port models that can quickly deliver reliable scattering, differential, and time-domain parameter measurements.
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
product
C-Band Separate Raman Fiber Amplifier
RFA5000
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.
-
product
Bending Deflectometers For ISO 178, JIS K 7171, And ASTM D790 Compliant Testing
After tensile testing, flexural tests are the most common strength tests for plastics and other resins. The main standards for plastic flexural (bend) tests are ISO 178, JIS K 7171, and ASTM D790, which require very accurate test systems. These standards include flexural strain measurements using a deflectometer, ranging from micro-strain measurements in the elastic region, the reversible elongation at the beginning of tests, to larger strain measurements in the plastic region. Shimadzu's deflectometers integrate easily into AG-X plus series, AGS-X series, and EZ-X test frames and Trapezium X testing software. Since these deflectometers push up against the specimen from below, the specimen color is not a limiting factor, as can be for laser type non-contact deflectometers. Furthermore, these deflectometers can partially absorb the shock during specimen failure, preventing specimen fragments from scattering.
-
product
Converter
556
The dual channel converter 556 provides continuous inline, real-time measurement and control of turbidity. The customer’s specific factory calibration of the converter can be configured in ppm (DE), FTU or EBC. Combined with an optek TF56-N scattered light sensor the 556 converter is a cost-saving measuring system, providing reliable process measurements.
-
product
Evaporative Light Scattering Detector for HPLC
ELSD-LT III
The evaporative light scattering detector (ELSD) is a general-purpose universal detector that can even detect components with no UV absorption, such as carbohydrates, lipids, surfactants, and synthetic polymers.* With exceptional sensitivity, a wide dynamic range through Analytical Intelligence features, and easy operability using LabSolutions™ software, the ELSD-LT III contributes to more effective analysis in a wide variety of fields.
-
product
Raman Spectroscopy
Raman is a spectroscopic technique that uses laser light to interact with molecular excitations and determine what a substance or element is composed of. It relies upon the inelastic scattering of photons which produces a weak signal, making the collection of information challenging particularly when the substance to be measured is at distance or can only be given short exposure times. Our Raman spectrometers are particularly effective at making Raman measurements due to their configuration which delivers a higher throughput/etendue than standard instruments.
-
product
VIS/NIR Sensor
AF26
The AF26 is a high precision dual channel color sensor for inline operation; the secondary wavelength is designed to compensate the desired light absorbance measurement from any undesired light scattering influence, such as suspended solids, gas bubbles, immiscible fluids or window fouling. The AF26 sensor’s output can be correlated to almost any color scale including APHA and Hazen.
-
product
Dynamic Light Scattering Systems
Since the release of the UPA in 1990, Microtrac would go on to become the preferred manufacturer of Dynamic Light Scattering instrumentation for nano-particle measurements. What makes our systems unique is our proprietary approach to Dynamic Light Scattering, which allows us to measure from sub-nanometer to several microns, in addition to, the ability to characterize the widest concentration range on the market.
-
product
Multiphoton Laser Scanning Microscope
FVMPE-RS
The Olympus FVMPE-RS multiphoton imaging system is purpose-built for deep imaging in biological tissue, aimed at revealing both detail and dynamics. Innovative features for efficient delivery and detection of photons in scattering media enable high signal-to-noise ratio acquisition. This translates to bright images with precise details — even from deep within the specimen. High sensitivity is matched with high-speed imaging to capture rapid in vivo responses. For advanced applications, dual-wavelength excitation extending to 1300 nm is available. Independent control of visible or multiphoton laser light stimulation and the ability to synchronize with patch clamp data are also possible.
-
product
Non-Contact Beam Profiler
BeamWatch
The patented BeamWatch non-contact profiling system accurately captures and analyzes industrial multi-kilowatt lasers wavelengths from 980nm - 1080nm by measuring Rayleigh Scattering. It features a complete passthrough beam measurement technique, no moving parts, and a lightweight compact design which makes it ideal for comprehensive analysis of industrial multi-kilowatt lasers
-
product
Application Specific LC System
Reducing Sugar Analysis System
The Nexera reducing sugar analysis system uses Shimadzu’s unique post-column boric acid-arginine fluorescence derivatization method. Unlike the refractive index detectors and evaporative light scattering detectors (ELSD) commonly used for sugar analysis, this system reduces the effects of impurities and offers both high sensitivity and a wide dynamic range. As a result, sugars contained in samples can be analyzed simultaneously, without dilution even when there are significant concentration differences.
-
product
Field-installation Type Turbidity Meter (Four-Wire Transmission, For Wide Range)
HU-200TB-W
HU-200TB-W is a turbidity meter developed to continuously measure turbidity in processes with large turbidity changes, such as water intake and sedimentation tanks in water supply plants. It employs transmission 90-degree scattered light method and is ideal for monitoring changes in processes with large turbidity changes from low range (10 degrees) to high range (2000 degrees). An electric wiper cleaning can be installed as an option, and long-term stable measurement is possible by periodic cleaning.
-
product
Nephelometric Turbidity Sensor
DTF16
The DTF16 is a high 3 channel turbidity sensor for installation into pipelines, measuring turbidity at two angles of scattered light and a direct reference channel in various liquid flow streams.





























