Filter Results By:
Products
Applications
Manufacturers
Organic LED
Light Emitting Diode with emissive electroluminescent layer composed of organic compounds.
-
product
Handheld Digital Multimeter, 4.5 Digit, Water and Dust Resistant
U1273A
Organic LED (OLED) display for high brightness level and wider viewing angles (up to 160 degrees)Features set that meet traditional industrial requirements and improve productivity and safety Improved accuracy and resolution to meet traditional industrial requirements (30,000 counts resolution with 0.6% for ACV accuracy)Intelligent features to improve productivity and safety (LPF, ZLOW, Smart )Better grip Visual and audible continuity indication in noisy environments Easy access to fuse for simplified maintenance Easy connectivity to PC and internal memory (up to 10,000) for data logging Large rotary switch and buttons that are easy to operate Dust and water resistant casing (IP 54 compliant)Compatible with U1177A/U1117A IR-Bluetooth adapter for remote monitoring & datalogging Altitude: 3000 meters
-
product
Handheld Digital Multimeter, 4.5-digit, with Organic LED Display (OLED)
U1253B
The Keysight U1253B 4.5-digit handheld digital multimeter (DMM) is feature-packed to simplify the troubleshooting of electronics and electrical circuits indoors, on the bench or in the field. Key capabilities include its organic LED (OLED) display that provides razor-sharp readings even in dark, off-angle situations. The U1253B is the world's first OLED handheld DMM of its kind. For those long, continuous measurements, the DMM equips you with the easy-to-use GUI data-logging software to automate virtually unlimited data recordings to PC. The U1253B comes with an integrated 20 MHz frequency counter for high frequency measurements, and a built-in programmable square-wave generator with selectable frequency and duty cycle. With the versatile U1253B, you are well equipped to perform thorough troubleshooting of any faulty circuit.A multi-award winner
-
product
S2 Blinx Digital Sensors
ULP-S2 BLINX
The Universal LightProbe S2 Blinx Digital is designed for the simple ON/OFF test of any color blinking or steady-state LED, for fast results with a digital output. The Universal LightProbe S2 Blinx Digital Sensors check the ON/OFF status of any color LED, whether stable or blinking/pulsed, up to a rate of 15 Hz, and provide a Logic “1” output (5 volts) only if the LED is “ON” and a Logic “0” if the LED is “OFF.”Operating temperature range: 0oC to 70oCPower consumption: Operates from +5, 12, 24 or 28 volts D.C., at 6mA max.Voltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsSignal Output Load: 20mA max. (Source/Sink). Non-inductiveOutput Pins: 3 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longOperating Temperature Range: 0hC to 70hCTypical response times: <66mS, shorter for brighter LEDsFiber-Optic Probes: Wide Aperture Fiber-Optic Probe recomended
-
product
S2 Unicolor Sensors
ULP-S2 SCI/V
The Universal LightProbe S2 Unicolor Sensor is designed for the intensity test of any single one of the five main LED colors (blue, green, yellow, orange, and red) plus white and Infrared (700nm to 1,000nm). Implemented in a unique and customizable 2-Part solution, the S2 Unicolor Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsSignal Output Loads: 20 mA max. Non-inductive.Output Pins: 3 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longOperating Temperature Range: 0hC to 70hCTypical response times:<10mS capture time; 65mS overall response time; intensity output of correct color only.Fiber-Optic Probes: Can utilize any Universal LightProbe Fiber-Optic Probe
-
product
Optical Contact POF Ext Ø 1mm For VPC RCV Mini Power 510104123
AN396
Optical contact probe for sensing LEDs.
-
product
18-Channel LED Analyzer
AL568
The format of the AL568 optical fiber for LED test is the most convenient and effective system on the market. It sits in the space of a 90 Series VPC module and only requires connection to a USB port to get data from up to 18 LEDs.
-
product
S2 Ultra High Sensitivity Sensors
ULP-S2 UHS
Universal LightProbe S2 Ultra-High Sensitivity Sensors are designed for the test of very dim LEDs, as low as 0.01 mcd minimum, and including very low light-level LED-illuminated action-indicator switches, controls and status indicators for night/dark viewing in automobile interiors. Recommend the use of wide-aperture stainless- steel encased Fiber- optic Probes with contacting tips.Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsSignal Output Loads: 20 mA max. Non-inductive.Output Pins: 3 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. long.Typical response times: <190mSFiber-Optic Probes: Wide-Aperture Fiber-Optic Probe recommendedDesigned for the test of very dim LEDs, as low as 0.01 mcd minimum
-
product
POF Ext Ø 1,5mm 600mm, from Light Probe to VPC ITA Contact (R)
YAV90CLR11
600mm Length. 1,5mm External diameter.
-
product
S2 Spectra Sensors
ULP-S2 WBI/V
The ULP S2 Spectra Sensor tests for LED intensity, and for any color in the visual spectrum, plus white. The S2 Spectra Sensor is well-suited for the test of “boundary” color LEDs, as it can unambiguously and repeatedly distinguish between not only adjacent visual colors such as green and yellow, but it can determine different hues of the same color such as yellow and amber, regardless of LED intensity. Implemented in a unique and customizable 2-Part solution, the S2 Spectra Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsOutput Pins: 4 gold-plated standard wire-wrap pins (0.025 in. sq.)Output Loads: ‘Int.’& ‘Color’- 2Kohms min., 100pF max.Sensor Size: 0.560 in. dia x 1.38 in. long.Typical response time: Typical response time: <10mS capture time; <100mS overall response timefor color and intensity simultaneouslyFiber-Optic Probes: Can be paired with any Universal LightProbe Fiber-Optic Probe
-
product
POF Ext Ø 1,5mm 600mm, from 5mm Lens to VPC ITA Contact
YAV90CLR10
The probes for sensing LEDs, P/N YAV90CR10 feature an Optical Head to correct missalignment errors in X and Y axis. As a result, the relative read out will oscillate less tan 5% with a missaligment of + 0,5 mm Offset
-
product
S2 Penta Sensors
ULP-S2 PCI/V
Optomistic Products’ best-selling Sensor, the ULP S2 Penta Sensor, is relied upon for its versatility in accommodating most LED color and intensity test applications. Implemented in a unique and customizable 2-Part solution, the S2 Penta Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption:Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsOutput Loads: ‘Int.’& ‘Color’- 2Kohms min., 100pF max.Output Pins: 4 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longTypical response times: Typical response time: <10mS capture time; <100mS overall responsetime for color and intensity simultaneouslyFiber-Optic Probes: Can be paired with any Universal LightProbe Fiber-Optic Probe
-
product
S2 Spectra USB Sensors
ULP S2 SPECTRA USB
Universal LightProbe S2 Spectra USB Sensors test a wide range of LED intensities and any color in the visual spectrum, plus white, providing a linear response with a serial digital output via a PC. A standard USB Cable is provided to connect to a mini-type B five-pin USB connector, which is integrated into the S2 Spectra USB Sensor.Operating temperature range: 0oC to 70oCOutput Port: A standard mini-type B five-pin USB connector is integrated into the S2 Spectra USB Sensor,and a standard USB Cable is provided to connect to a USB portSensor Size: 0.560 in. dia x 1.38 in. long.Typical response time: < 10mS for color and intensity as a serial bit- stream (19200 baud rate)Fiber-Optic Probes: Can be paired with any of a wide range Universal LightProbe Fiber-Optic Probes
-
product
S2 Unicolor Digital Sensors
ULP-S2 SCC
The Universal LightProbe S2 Unicolor Digital Sensor is pre-programmed to respond only to a specific color LED, including blue, green, yellow, orange, red, plus white. The Universal LightProbe S2 Unicolor Digital Sensor is designed for the simple ON/OFF test and color check of a single color LED, with a digital output, quickly determining PASS/FAIL status without further processing by Automatic Test Equipment. The Universal LightProbe S2 Unicolor Digital sensor provides the simplest and fastest interface to Automatic Test Equipment (ATE).Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts, at 6mA max.; less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsSignal Output Loads: 20 mA max. Non-inductive.Output Pins: 3 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longOperating Temperature Range: 0hC to 70hCTypical response times: <10mS capture time; <65mS overall response timeFiber-Optic Probes: Can utilize any Universal LightProbe Fiber-Optic Probe
-
product
Organic Pollutant Monitor
OPSA-150
The OPSA-150 is a organic pollutant monitor that uses HORIBA's proprietary Rotary Cell Length Modulation, a measuring technique incorporating 25 years of expertise. The unit can be used as an organic pollutant monitor at drainage systems for determining compliance with COD monitoring regulations, for monitoring quality of water measuring levels of organic matter at water supply intakes, and as an organic monitor on process lines (phenol meter).*Pole mount, outdoor cover, and analysis panel are available as options.
-
product
S2 Penta High-Sensitivity Sensors
ULP S2 PCI/V HS
The Universal LightProbe S2 Penta High Sensitivity Sensor features the same popular built-in color binning as the regular S2 Penta Sensor, and is designed test extremely dim LEDs, providing an analog output for intensity, ranging from 0 to 4 volts, corresponding to the LED’s luminous intensity in millicandelas. Implemented in a unique and customizable 2-Part solution, the S2 Penta High Sensitivity Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsOutput Pins: 4 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longTypical response times: <1.2s color & intensity outputs simultaneously (the brighter the LED, the shorter theresponse time)Fiber-Optic Probes: Wide Aperture Fiber-Optic Probe recommended
-
product
LED synchroscope
LS-110 SYNC (110V, 120V, 220V, 230V, 240V)
Standard Electric Works Co., Ltd
• Input Voltage : 110V AC, 120V AC, 220V AC, 230V AC or 240V AC.• Standard 4.5-inch switchboard case.• Front panel mount.• 3 bi-colored LED indicators for "SYNC", "GEN" and "BUS".• 24 LEDs in a circle display the phase angle and the frequency differences between 2 networks.• 360° LED indication.• 12 o'clock position LED is bi-colored.
-
product
LEDs
Opto Diode manufactures best-in-class light-emitting diodes (LEDs) for a wide variety of applications that require rugged, hermetically-sealed packaging that can withstand extreme temperatures. Choose from our visible, near-infrared in wide, medium or narrow light patterns, our high-output visible LEDs in red or blue with narrow beam angles, or our high-power near-IR LEDs for night vision and surveillance applications. Ideal for medical, automotive, scientific, commercial, imaging, aerospace, and other demanding military or industrial tasks.
-
product
LED Test
Neosem developed and released the LX500 - LED Accelerated Aging Tester to provide our customers with the capability to deliver highly reliable automotive LED products to the market. By adopting Neosem’s patented temperature control algorithm, the customer can execute the LED device aging test at very stable temperatures.
-
product
LED Spectrometer
The New Feasa LED Spectrometer has been designed specifically to allow testing of LEDs on populated PCBs where access is limited. The Feasa LED Spectrometer includes customised on-board firmware for automatic colour calculation in multiple colour spaces. It uses a similar easy to use set of commands as the Feasa LED Analyser. When your quality demands Traceable Measurements the Feasa LED Spectrometer provide an ideal solution.
-
product
LED Indicators
The "semi-analog" LED indicators display the measured value using 71 LEDs. These indicators are designed to withstand very strong vibrations yet have the familiar look of an analog indicator.
-
product
LED Analytics
colorCONTROL MFA
The colorCONTROL MFA is used for measurement of color and intensity on LEDs, displays, and colored objects. An additional benefit is the flexible positioning of the small fibers to the targets. By utilizing the colorCONTROL MFA up to 495 measurement points can be monitored simultaniously.
-
product
LED Stroboscopes
Our LED stroboscopes use solid-state light sources that are very durable and long lived with no heat generation or drift over time. They feature push button control of all digital functions and pulse width modulation to ensure sharp images at high speeds and aluminum housings.
-
product
LED Display for SysMon
060-013
LED Display accessory for System Monitor (SysMon) with 11 LEDs and push button to generate a SYSRESET# signal directly from the front of the system.
-
product
Universal LightProbe S2 Sensors
Optomistic Products’ Universal LightProbe S2 Sensors are designed for the In-circuit, Functional or Finished Product test of an LED’s color and/or intensity. Implemented in a unique and customizable 2-Part solution, the S2 Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.
-
product
3 Digit LED Voltmeter
SP 300
The SP 300 is a 3 digit LED voltmeter with 9mm (0.36") digit height. It features 200mV d.c. full scale reading, auto-zero and auto-polarity. The meter plugs directly into an 8-way SIL socket and can be fitted into a panel via the fixing clip. Splashproof protection to IP65 is achieved by fitting the seal supplied.
-
product
LED Load Simulator
63110A/ 63113A/63115A
As shown on the V-I curve in figure 1, the LED has a forward voltage VF and a operating resistance (Rd). When using a resistor as loading, the V-I curve of the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1. This may cause the LED driver to not start up due to the difference in V-I characteristic between the resistors and the LEDs. When using Electronic Loads, the CR and CV mode settings are set for when the LED is under stable operation and therefore, is unable to simulate turn on or PWM brightness control characteristics. This may cause the LED driver to function improperly or trigger it’s protection circuits. These testing requirements can be achieved when using a LEDs as a load; however, issues regarding the LED aging as well as different LED drivers may require different types of LEDs or a number of LEDs. This makes it inconvenient for mass production testing.
-
product
3 Digit LED Voltmeter
DPM 340
The DPM 340 is a 3 digit LED voltmeter with 8mm (0.31") digit height. It features 200mV d.c. full scale reading, auto-zero and auto-polarity. The meter plugs directly into a SIL socket or can be snapped into a panel. Connection to the meter is via a single row of pins
-
product
LED Tester
Iskra ST5-L
*Convenient one-hand operation*Ideal for Surface Mount Devices*Automatic LED polarity detection and display*Forward drop voltage display*Dedicated mode for testing bi-directional LEDs*Manual polarity preset modes*Adjustable constant test current 1-30mA*Adjustable test duty cycle 10-1000 mSec*LED visual brightness verification*LED visual color verification*OLED Display*Integrated Li-Ion battery