Electrodes
-
Product
Parallel Electrode SMD Test Fixture
16192A
Test Fixture
The 16192A test fixture is designed for impedance evaluations of side electrode SMD components. The minimum SMD size that this fixture is adapted to evaluate is 1(L)[mm].
-
Product
Tracking Index Test Apparatus
CX-L19
-
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
Product
High-Purity Graphite Sheet Counter Electrode
EG-1
-
High-purity graphite sheet counter electrode with PTFE holder, designed for stable current return in three-electrode electrochemical cells. Suitable for CV, EIS, bulk electrolysis, and chronoamperometry in aqueous and non-aqueous systems. Available in standard sizes from 10 × 10 × 3 mm to 70 × 70 × 4 mm, with custom dimensions and holder configurations available upon request.
-
Product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196C
Test Fixture
The 16196C surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
Product
50μm Ceramic Interdigitated Electrode Chip
CIE1
-
50μm ceramic interdigitated electrode chip for biosensing, gas sensing, humidity monitoring, and capacitive sensor research.
-
Product
Eurostat Turnstiles
-
For companies who need to ensure that the operators cannot enter the EPA unless their wrist straps and footwear are compliant every day• The turnstiles comply with ANSI/ESD S20/20 specification and ISO standards record keeping requirements • Both ESD safe shoes are tested separately through measuring electrodes, installed in the contact mat.• This system tests operators quickly (≤ 3 sec) and automatically and generate reports for the ESD coordinator• Communication with a server for traceability (Operator ID, Time & Date, Test values etc…)• LCD screen showing real time measurement• Keypad• Hygrometry measurement• Choice of measuring ranges and system calibration directly with the software• HID Wiegand interface, compatible to any HID card format
-
Product
Ring Disk Electrode
-
This ring-disk type electrode developed by NTT Advanced Technology Corporation is a form of printed electrodes. Users can choose them from Carbon, Gold and Platinum applied versions. Available as a working electrode of radial flow cells, achieves complete reduction/oxidation on the center disk at ultra-low flow rate because of its fine coulometric electrolysis efficiency. This also enables to analyze subsequent reaction as well as identification and quantitation of the sample at the same time.
-
Product
30μm Silicon Interdigitated Electrode (IDE)
SBE1
-
30 μm silicon interdigitated electrode (IDE) for MEMS, gas sensing, biosensing, and electrochemical applications. High-precision microfabrication with customizable sizes and electrode configurations for research and OEM projects.
-
Product
Nexis GC-2030 BIDUFRGA
UFRGA Series
-
The Ultrafast RGA system utilizes the new Barrier Discharge Ionization Detector (BID) technology coupled with Nexis GC-2030 to create new system GC for ultrafast, high-sensitivity analysis. Since the electrode creating Helium plasma is totally isolated from the carrier gas, there is no chance to contaminate this electrode with a dirty sample. This enables long-term stability.
-
Product
Concrete Moisture Meter
7410
-
The electrodes transmit parallel low frequency signals, calibrated to give average moisture content by comparing the change in impedance between damp and acceptably dry concrete.Calibrated ready for use on concreteInstant readings on a clear, easy to read scaleFully portable, battery operated and non-destructive
-
Product
pH Meter Hanna Make All
-
pH meter is an electronic device used for measuring the pH which is either the concentration of Hydrogen ions in an aqueous solution or the activity of the Hydrogen ions in an aqueous solution. The pH will indicate if the solution is acidic or basic, but is not a measure of acidity or alkalinity.[1] pH meters work in liquids though special probes are sometimes used to measure the pH of semi-solid substances. A typical pH meter consists of a special measuring probe (a glass electrode) connected to an electronic meter that measures and displays the pH reading
-
Product
Room Temperature Sample Holders
12962A
-
The 12962A sample holder is designed to allow accurate impedance tests of solid materials to be performed at room temperature. The sample holder consists of two parallel electrodes, one of which is fixed in position and the other which can be moved into contact with the sample by adjustment of a micrometer. The sample holder makes use of guard ring and reference techniques in order to improve accuracy by reducing “fringing” effects at the edge of the sample. The standard electrode provided is 20mm diameter.
-
Product
pHTestr® 50 Waterproof Pocket pH Tester,
-
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
Product
Portable ORP Meter
YK-23RP
-
ORP meterElectrode included,Electrode dimensions: Dia 12.5mm height, 120mmBNC connectorMeasuring range -1.999mV to +1.999mVResolution: 1mVResistance: 10MohmDC 9 volts, 1mASize: (H*W*D)mm, (205*68*30)mm
-
Product
Low TCR High Power Current Sensing Resistors, Wide Terminal Type
-
Panasonic Industrial Devices Sales Company of America
Panasonic's ERJ-D1 and ERJ-D2 Series, Low TCR High Power Current Sensing Chip Resistors, achieve high power and low TCR (±100×10–6/°C) using a wide terminal electrode structure and original materials.These Resistors are suitable for small size/high power current detection and their low TCR enables high accuracy of current detection. The ERJ-D1 Series features higher rated power at 2W in a 1020 case size while the ERJ-D2 Series features 1W in a 0612 case size. These Resistors are AEC-Q200 Compliant and offer IEC 60115-8, JIS C 5201-8 and EIAJ RC-2134B Reference Standards ensuring optimal quality and reliability.
-
Product
Ocean and River Instruments
RINKO W
-
Rinko W is an autonomously deployable data logger for long-term DO measurements. In order to protect the sensing foil against accumulating bio-fouling, the instrument has a mechanical wiper to sweep the optical window. The optical sensor does not have a membrane neither electrolytes, thus, it need less maintenance than electrode or galvanic sensors.
-
Product
Walking Test System Kit
PGA-710
-
The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.
-
Product
Nutrient- NH4, NO3
-
The HYDRA-DS Nitrate Analyzers are designed to monitor the nitrification process directly in the aeration basin or clarifier of a Waste Water Treatment Plant. The HYDRA Nitrate Sensor uses ISE technology to measure the Nitrate. Chloride ions interfere with the Nitrate Ion Electrode, compensation for the chloride ion interference on the nitrate electrode is preformed automatically in the T80 HYDRA-DS analyzer.
-
Product
Micro Volume pH Monitor
UP-100
-
Redevelops HORIBA's founding pH measurement technology using new ultra-small capillary electrode. HORIBA's UP-100 affords ultra-low sample consumption of just 500 uL/measurement, enabling continuous pH monitoring for a variety of critical manufacturing processes that include Semiconductor (Cleaning, Etching and Plating); Chemical Manufacturing, Bio, Pharm, Food Processing, etc.Designed for 6 month continuous operation without operator intervention for minimizing downtime.
-
Product
Capacitive
VEGACAL
-
In capacitive level measurement, the sensor and the vessel form the two electrodes of a capacitor. Any change in level causes a capacitance change, which is in turn converted into a level signal.
-
Product
TTC-1 Tracking Test Chamber
TTC-1
-
It is according to IEC60695 and IEC60112 (GB4207), the Tracking Test Chamber TTC-1 is intended for determining the degree of protection against formation of conducting paths in solid insulating materials, due to the electric stress and electrolytic contamination of the surface. This method simulates tracking currents on insulation material by providing drops between electrodes. During the process of normal use, insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.
-
Product
10μm Transparent Quartz IDE Chip
TID1
-
The TID1 10um Transparent Quartz IDE Chip is an interdigitated electrode chip designed for gas sensing, humidity sensing, biosensing, impedance measurement, and MEMS-related electrochemical or electrical detection research. The 10 um transparent electrode geometry provides a defined interdigitated pattern for surface-functionalized sensing experiments. The quartz glass substrate supports optical access, transparent sensing, and photoelectric detection, while the IDE layout helps improve interaction between the electrode fingers and the target film, electrolyte, vapor, or biological interface.
-
Product
Open Flanges Test Rig
-
Flexible cell dimensions: cells of Ø 8 to Ø 80 mm (or square till 70x70 mm) can be successively installed Quick start of experiment: less than 20 minutes to remount a new cell with different dimension, thanks to the simple design without sealing Other SOFC components: the open flanges test rig is also useful for conductivity measurements (electrolyte, electrode material, interconnect etc.) and sealing tests End of broken cells and secure testing: the cell is squeezed by a soft alumina felt that prevents any damages, the excess fuel burns continuously in the alumina felt at the cell edges
-
Product
Crossed-Field Amplifiers
CFAs
-
Communications & Power Industries
CPI BMD’s crossed-field amplifiers (CFAs) are broadband, phase-stable microwave amplifiers used in coherent radar chains to efficiently generate very high peak output powers from relatively low input voltages which can be either applied to the cathode or an electrode similar to a TWTs cathode or grid pulsing, and in relatively small, lightweight packages. These characteristics make CFAs particularly well-suited for applications in which the transmitter must be either airborne, transportable, mobile or portable.
-
Product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
Resistivity Cell
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
Product
Ion 700 Benchtop Meters
-
Oakton benchtop 700-series meters are designed for use in crowded laboratory settings. Compact footprint of less that 6" x 7" (16 x 18 cm) conserves valuable space, while the large, dual-display LCD provides excellent visibility—even from a distance. Ion 700 meter measures pH, mV, relative mV, ion concentration and temperature. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Models feature five-point pH calibration with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers. Meters additionally feature ion concentration calibration of up to 5 points. Meter features include Auto-Hold, selectable °F or °C measurement, and easy recall of electrode slope or offset. The convenient pull-out quick reference card keeps procedures handy at all times. Use 700-series meters with any pH, ORP, or ISE electrodes with a BNC connector.
-
Product
Single Channel Potentiostats
-
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
Product
T-Type Platinum Sheet Electrode Clip
TTP-1
-
TTP-1 T-Type Platinum Sheet Electrode Clip is an electrode holder, clip or electrochemical cell accessory designed to position electrodes securely and provide stable electrical connection during laboratory electrochemical testing.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Multi-probe for Ammonium and/or Nitrate
S470
-
S470 is a complete family of Ion selective electrodes (ISE) probes suitable for monitoring the performance of the ammonium ion (as NH4+ or NH4–N) and nitrate ion (as NO3– or NO3–N) in a liquid matrix.





























