Product
Oil Test Set
-
RR-OIL TEST SET also known as OIL BDV KIT is an equipment-designed and produced to test the ELECTRICAL STREGTH of Liquid Insulating Materials such as Transformer Oil, Capacitor Oil etc. The test set carries out test on these materials as per Indian Standard Specification IS 6792. This Oil Test Set is essential for Transformer & Switchgear Manufacturers, also for oil filtration units.
-
Product
Switch Box for Fully Automatic Testing
CP SB1
-
The switchbox CP SB1 reduces wiring work at power transformers. Thereby, the time needed for testing can be reduced and, at the same time, safety can be significantly increased.
-
Product
Condition Monitoring
-
Condition Monitoring by TP - generator, turbine, and transformer condition monitoring
-
Product
Transformer Degaussing Analyzer
KRI6691
-
The KRI6691 transformer degaussing analyzer injects current into the test winding by applying ±90V voltage, and collects the terminal voltage and winding current to draw the hysteresis characteristic curve. Linear quantitative analysis of transformer remanence can be performed, and rapid demagnetization can be achieved by tracking the hysteresis curve.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Transformer Rectifier Assemblies
-
Transformer rectifier assemblies are very useful in OEM applications when unregulated DC output is required. Input power can be single-phase or three phases. With single-phase input power, the output ripple is 50%. With three-phase input power, the output ripple is 5%. A 5% output ripple is a clear advantage. Hence, transformer rectifier assemblies with three-phase input power are more popular. Circuit breakers, fuses, voltmeters, and ammeters can be added per customer requirements. The assemblies can be an open frame or inside an indoor enclosure.
-
Product
Trace-level, Photolytic, True NO2/NO/NOx Analyzer
Model T200UP
-
Teledyne Advanced Pollution Instrumentation
The Model T200UP provides trace level measurements of NO and NO2 using our Model T200U NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.
-
Product
High Voltage System
HV-2
-
International Electro-Magnetics, Inc.
*Tests Power Transformers for Continuity, Ratio and Phase. Applied and Induced Potential and No-load Losses.*14 Conductor Switching Matrix will test 7 individual windings, 13 taps of one common winding or some combination thereof. (10 Amp current limit)*The System Control is Windows/Visual Basic based. Menu screens allow full selection of test parameters and sequence. Low voltage tests can be performed first, allowing defective parts to be rejected without proceeding to time consuming induced Potential dwell routines. Test data labeling and data acquisition software can be easily added to the system.
-
Product
Large Current 1000A Primary Current Injection Test Set
TEST-901
-
Beijing GFUVE Electronics Co.,Ltd.
TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.
-
Product
High Current Calibrator
MC151
-
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
Product
Current Transformer
ST-30CT
-
Standard Electric Works Co., Ltd
● 30/5A - 150/5A● 2-3V A● Class 1● Insulation 600V
-
Product
Tap Adapter
-
Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.
-
Product
GPIB-RS232, Instrument Control Device - Japan 100VAC
779732-07
GPIB Controller
The GPIB‑RS232 is an IEEE 488 controller device for computers with an RS232 port. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS232 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS232 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488 and RS232 standards, as well as interpret and execute high-level commands from the serial port, including RS232‑to‑GPIB and GPIB‑to‑RS232 protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.
-
Product
Force Tensiometers
Sigma 702ET
-
The Sigma 702ET Transformer Oil Analyzer has been specifically designed to guide the user through the measurement of interfacial tension of transformer oil according to relevant standards.
-
Product
Combustible Gas Meter
921A
-
The Arbiter Systems®, Inc. Model 921A Combustible Gas Meter is a rugged, portable instrument that measures total combustible gases (TCG) in oil-filled transformer nitrogen gas blankets. TCG measurements have been shown to be good indicators of transformer health.
-
Product
8-Channel VME LVDT/RVDT Scanner
V550
-
The V550 is a 6U, one-slot VME module which will acquire position data from up to eight LVDT (linear variable differential transformer) position sensors. The LVDT sensors are excited by an ultrastable synthesized sinewave generator, and conditioned by a precision 16-bit A/D converter followed by digital signal processing. The resident microprocessor supervises scanning and signal conditioning, and places updated position data in VME-accessible dual-ported data registers for instant access from the VME bus.
-
Product
Iron Core Earth Tester
-
Weshine Electric Manufacturing Co., Ltd
Transformer iron core grounding current tester is a high-precision clamp meter specially designed for measuring AC leakage current, current and voltage. Large diameter (80×80mm) can clamp φ80mm cable, or 96mm×4mm flat steel ground wire, suitable for cables Leakage detection and transformer grounding flat steel leakage measurement.
-
Product
PNA Microwave Network Analyzer
N5224A
Network Analyzer
Reach for unrivaled excellence in your measurements and designs Transform deeper understanding into better designs with the PNA's outstanding measurement integrity Meet your toughest measurement challenges with the highest performing microwave network analyzer in the industry Get the best accuracy with Keysight's S-parameter measurements Meet your specific budget and measurement needs by customizing to just the right level of performance. Every spec verified, adjustments included Lock in support & peak performance from the start
-
Product
Standard Tap Position Indicator
-
NMC,s Tap Position Indicator is a Microprocessor based specially designed instrument used to indicate the Tap Position of the Power Transformer with On Load Tap Changer.
-
Product
Software and Interfacing
-
The installed sophisticated software offers many possibilities for signal storage, processing, visualization, etc. This includes the Fourier Transform analysis, and the line shape fitting of resonance. The system can also control external devices through the GPIB interface.
-
Product
Multimode Data Controller
PK-232/PSK
-
Timewave’s customers swear by their DSP filters and PK-232 owners love the flexibility and reliability of the most popular data controller ever built. Now with the addition of a sound card interface, the PK-232/PSK rolls it all into one! The PK-232/PSK brings a new level of performance to the legendary PK-232 with sharp, accurate DSP filters for all its internal data modes and dual transformer isolation for sound card data modes. Weak signals magically appear from the noise and QRM bounces off the new DSP filters for cleaner copy with fewer errors than the old analog filters.
-
Product
Injection Transformer
J2101A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Electronic Transformer Test System
UI2000-ET
-
• Input characteristics analysis 1) Measure Vrms (10-300V) Lrms (0.04-4A) W, PF, Hz, total harmonic and 0-50 component of harmonic 2) Accuracy: ± (0.4%reading + 0.1%range + 1digit) • Output characteristics analysis 1) Measure lamp voltage (1-60V) lamp current (03-20A) lamp power, crest factor and oscillatory frequency 2) Accuracy: Class 2 • It can print without compute, and provide the communication port for PC
-
Product
Transformer Turn Ratio Instrument
ART-3D
-
The ART-3D is high precision instrument designed to measure ratios, magnetization currents, phase-shifting in power transformers, distribution transformers, potential and current transformers, in conformity to IEEE C57.12.90 and CEI/IEC 60076.
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Current Transformer
ST-60CT
-
Standard Electric Works Co., Ltd
● 400/5A - 800/5A● 7.5-10V A● Class 1● Insulation 600V
-
Product
DC Resistance Tester
GDZRS-20A
-
GDZRS series Winding DC resistance tester is optimal designed for measuring three phase winding DC resistance of big capacity transformer. It can test three phase winding DC resistances at the same time
-
Product
Automated Unit Testing
Topaz for Total Test
-
Compuware Topaz for Total Test transforms mainframe application development by automatically creating tests for logical units of code. Developers at all skill levels can thus quickly and easily perform unit testing on COBOL code just as they do in Java, PHP and other popular programming languages. In fact, Topaz is more advanced than typical Java tools, because it requires no coding and automatically generates default unit test result assertions for developers. The introduction of Topaz for Total Test follows two years of unmatched innovation by Compuware across all key aspects of mainframe application agility, integration of the mainframe into the broader context of cross-platform enterprise DevOps, and the ongoing attrition of veteran IT professionals with specialized mainframe knowledge.
-
Product
Turns Ratio Meter
Model TRM200
-
Turns Ratio Meter Model TRM200 is widely used in transformer industry in manufacturing and repairing service. It directly display the ratio of LT turns & HT turns. It is capable to measure turns ratio till 1:1200. Turns ratio meter is designed to be a rugged and reliable. It is equipped with stable 250mA source. The design is based upon in-house invented & patented technology. TRM200 has also option for 1amp current source on demand.