Compensators
-
product
Compensating Reactor
RCTD
This module is properly designed for testing Tan Delta in rotating machines with TD 5000 and allows increasing the test current and getting the maximum test voltage with high capacitive burdens
-
product
Bluetooth® Enabled ORP/REDOX & Temperature Pen
UltrapenX2™ PTBT3
*Accuracy of ± 10 mV ORP*3 Calibration Options with Automatic Solution Recognition*Automatic Temperature Compensation in Calibration Mode*99.9% Pure Platinum Electrode*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Powered by One N Type Battery (Included)*Waterproof
-
product
Passive Probe, 10:1, 500 MHz, 1.2 M
N2843A
The Keysight N2843A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
product
Brix Meter
Hand-held, digital brix meterLight-weight, portable, includes protective carrying caseMeasures concentration of sugar and dissolved solids in aqueous solutionAutomatic Temperature Compensation (ATC)Ideal for on-site measurement of juices and other sugar-based liquidsDetermine fruit quality during harvest, shipping, receiving, processing, storage
-
product
Multi-channel Resistance Meter
Changzhou Applent Instruments Inc.
Can scan and test 10 channels of resistance and can set a comparator for each channel. Its temperature compensation function can adapt different testing requirements. It can be applied to automation equipment.
-
product
Flame Ionization Detector
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
product
Restrained Airspeeds
These airspeed indicators have restrained movements.These instruments are actuated by ram air and ambient atmospheric pressure obtained from the aircraft pitot and static pressure systems. A moveable pointer and a fixed dial indicate airspeed with the zero index at the 12 o’clock position. Temperature compensation is internal and there is no external zero adjustment. Pointer damping is internally adjustable.
-
product
MAX PH/ORP/ISE/Temp Logging Bench Meter
MW160
The Milwaukee MW160 4-in-1 MAX pH/OPR/ISE/Temp. Logging Bench Meter has won fans around the world with its reliable, fast, simple operation as well as a tough, sleek, lightweight design with a small lab space footprint. It is cccurate to ±0.01 pH with automatic or manual temperature compensation, and built in dedicated GLP key. In addition, up to 3-point automatic calibration and 7 selectable buffer standards makes the MW160 MAX ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
-
product
Mechanical Force Gauges
Imada mechanical force gauges are highly accurate instruments used to test the quality, strength or functionality of component parts or products. Imada mechanical force gauges check both compression and tension (push or pull). Peak force can be captured using the peak indicator needle and the tare ring compensates for the weight of attachments. Imada force gauges are constructed with a heavy-duty metal case and all metal components to enable them to retain their calibration for years with proper care. These mechanical force gauges never need charging or batteries and are intrinsically safe in hazardous environments.
-
product
C-Band Separate Dispersion Compensation Raman Fiber Amplifier
DRA5228/F
Hangzhou Huatai Optic Tech. Co., Ltd.
Raman Fiber Amplifier (RFA) utilizes the optic gain in the Stimulated Raman Scattering (SRS) in the optical fiber and realizes the amplification of the signal optic. FRA, with very low equivalent noise and a wide gain scope, can further widen the gain bandwidth by adopting multi-wavelength optical bump, which represents the development direction of the new optical fiber amplifier.
-
product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
product
Special Purpose Probes
6100 Series
Similar to a standard 10X scope probe except with BNC connections on both ends. With BNC connections on both ends, it provides a more stable connection when connecting to other equipment. This eliminates the use of a standard probe with a BNC adapter on the probe end that could come loose or break off the probe tip. The lead can be compensated to your scope with the trimmer tool included.
-
product
Nutrient- NH4, NO3
The HYDRA-DS Nitrate Analyzers are designed to monitor the nitrification process directly in the aeration basin or clarifier of a Waste Water Treatment Plant. The HYDRA Nitrate Sensor uses ISE technology to measure the Nitrate. Chloride ions interfere with the Nitrate Ion Electrode, compensation for the chloride ion interference on the nitrate electrode is preformed automatically in the T80 HYDRA-DS analyzer.












