Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Optical/Electrical Clock Recovery
N1077B
Clock and Data Recovery Unit
N1077B Optical/Electrical Clock Recovery provides standards-compliant clock recovery capabilities for multimode and single-mode optical as well as electrical signals from 125 MBd up to 64 GBd PAM4 and NRZ
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
Terminal Block For 34951A And L4451A D / A Converter
34951T
Terminal Block
Provides a flexible method for connecting discrete external wiring; detachable with screw-type connections.
-
Product
4-Quadrant General-Purpose Source/Measure Unit, ±20 V, ±1 A Or ±6 V, ±3 A, 20 W
N6784A
Source Measure Unit
The Keysight N6784A is a source/measure unit (SMU) designed for general-purpose precision sourcing and measurement. General-purpose applications can span many different industries and many different devices under test (DUTs). The N6784A SMU is a versatile tool designed to tackle many of these general-purpose applications. Its glitch-free operation ensures safe usage with the DUT during output and measurement range changes, even with capacitances of up to 150 µF. Its 4-quadrant operation enables it to act as a bipolar power supply or a bipolar electronic load, for added versatility. When using the N6784A SMU, engineers can be confident that they have an all-around general-purpose tool for their test systems or lab bench.
-
Product
TB-2634, Screw Terminal, Ribbon, 4x64, 1-Wire PXI Module Matrix Terminal Block
778840-01
Terminal Block
Screw Terminal, Ribbon, 4x64, 1-Wire PXI Module Matrix Terminal Block - The TB-2634 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 1-wire 4×64 matrix. You can directly connect the TB-2634 to the front panel I/O connectors of the PXI-2529. The … TB-2634 includes ribbon cable headers that provide access to the rows and columns of the matrix.
-
Product
EBIRST 100-pin SCSI Termination Fixture
93-019-104
SCSI Female Terminator
93-019-104 eBIRST Termination Fixture is part of a range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces PXI, LXI or PCI controlled switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix Topology Without Column Protection Resistors
782385-11
Terminal Block
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
PXI 16-Channel 4-Bus 2A Fault Insertion Switch
40-197A-002
Fault Insertion Unit
This 16-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers.
-
Product
SCB-100 Noise Rejecting, Shielded I/O Connector Block
776990-01
Terminal Block
100-Pin Female SCSI to 100-Pin Female Screw Terminal, Desktop Mount Terminal Block - The SCB-100 is a shielded I/O connector block for interfacing I/O signals to NI data acquisition devices with 100-pin connectors. Combined with the shielded cables, the SCB-100 provides rugged low-noise signal termination.
-
Product
PXI Remote Control Interface Cable, 3m
41-924-300
Remote Interface Cable
The 41-924-300 is a 3m cable accessory for the PCIe to PXI Remote Control Interface Kit. The kit provides a seamless connection between a PC’s PCIe slot and a PXI chassis and is suitable for providing an interface to any PXI chassis.
-
Product
CB-37FH, DIN-Rail Horizontal Mount 37-Pin Spring TB
778676-01
Terminal Block
37-Pin Female D-SUB to 37-Pin Female Connector, Horizontal DIN-Rail Terminal Block - The CB-37FH is an unshielded terminal block that provides access to NI data acquisition devices with 37-pin female D-SUB connectors. The CB-37FH mounts in line with the DIN rail, and it featuresscrew or spring terminals for connecting to 37 I/O signals, 12 to 30 AWG.
-
Product
PXIe Precision Source/Measure Unit, 15 MSa/s, 100 FA, 60 V, 3.5 A DC/10.5 A Pulse
M9603A
Source Measure Unit
The Keysight M9603A is a PXIe precision SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
One System® Remote Video Terminal
OSRVT™
-
The One System® Remote Video Terminal (OSRVT™) delivers full-motion video, images and critical geospatial data from a variety of sources directly to the warfighter’s fingertips. Today, we are delivering the next-generation OSRVT to U.S. Army, Marine Corps and Special Operations Forces customers, equipped with bidirectional capability, upgraded software architecture and a more user-friendly interface.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
4x 3U OpenVPX MOSA Data Concentrator Unit
SIU34-DCUVARM-01
Data Concentrator Unit
SIU34-DCUVARM-01 is a Modular Open Systems Approach (MOSA) DO-178C & DO-254 Certifiable Data Concentrator Unit (DCU) with low power high performance OpenVPX Xilinx UltraScale+ SBC with Quad Core ARM Cortex -A53, 8 GB DDR4 SDRAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet, USB 3.0, FIPS-140-3 Level 3 Cyber Security, and Single Event Upset support.
-
Product
Integrated AI-ADAS ECU And Cameras For Large Commercial Vehicle
ADM-TJ30
Electronic Control Unit
The integrated AI-ADAS ECU is connected to 8 cameras and powered by the vision-AI algorithm. It can detect and classify different kinds of vehicles/ pedestrians/ two-wheeler riders/ lane marking and other objects to perform multiple ADAS functions.
-
Product
CB-68LP, Low-Cost, Unshielded I/O Connector Block
777145-01
Terminal Block
68-Pin Female VHDCI to 68-Pin Female Screw Terminal, Desktop Mount Terminal Block - The CB-68LP features 68 screw terminals for easy connection of field I/O signals to 68-pin NI data acquisition devices. It includes one 68-pin male SCSI connector for direct connection to 68-pin cables. This connector block features standoff feet for use on a desktop or mounted in a custom panel. The CB-68LP also has a vertical-mounted, 68-pin connector.
-
Product
USB Source Measure Units
Source Measure Unit
The U272xA is a 3-channel USB SMU that can operate in a 4-quadrant operation. It can function as a standalone module or used as a modular device, allowing expansion and compact solution when used with the other modules in the USB Modular Instruments and DAQ family.
-
Product
Electrical Clock Recovery
N1076B
Clock and Data Recovery Unit
The N1076B Electrical Clock Recovery provides standards-compliant clock recovery capability on electrical NRZ and PAM4 signals from 125 MBd up to 64 GBd
-
Product
3U OpenVPX Sensor Interface Unit
SIU34
Sensor Interface Unit
The SIU34 is a highly configurable rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, communications, Ethernet switching and processing. The SIU34 leverages NAI’s 3U OpenVPX™ boards to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
Product
Coaxial Termination, DC to 50 GHz
85138A
Terminator
The Keysight 85138A is a precision, low-reflection dc to 50 GHz load for terminating a 50-ohm coaxial system in its characteristic impedance. It is intended for use as a calibration standard. The Keysight 85138A has a 2.4 mm male connector.
-
Product
Open Termination, 4-Terminal Pair
42090A
Terminator
The 42090A is an open termination and is primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using this standard.
-
Product
Source/Measure Unit for Functional Test, Multiple Ranges, 80 W, Double-wide
N6786A
Source Measure Unit
Only Keysight`s N6780 Series SMUs let you visualize current drain from nA to A in one pass and one picture unlocking insights to deliver exceptional battery life.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
PXIe-4147, 4-Channel, ±8 V, 3 A Precision PXIe Source Measure Unit
786888-01
Source Measure Unit
PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit - The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. The sample rate of the PXIe-4147 can reduce measurement times, capture transient device characteristics, and help you perform current-voltage (I-V) characterization of devices-under-test (DUTs). With a high-speed sequencing engine, you can synchronize SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4147 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Terminal Block For 34950A 64-Bit Digital I/O
34950T
Terminal Block
Use to easily connect discrete wiring to a terminal block for the Keysight L4450A 64-bit digital I/O.