Product
CB-37F-LP Unshielded, I/O Connector Block with 37-pin D-Sub
779353-01
Terminal Block
37-Pin, Female D-SUB to 40-Pin, Female Screw Terminal, Desktop Mount Terminal Block - The CB-37F-LP is an unshielded terminal block that provides access to DAQ devices with 37-pin connectors. The 37-pin, D-SUB connector makes this connector block ideal for direct mounting on the … DAQ device or connecting through a cable.
-
Product
NI 9923, Front-mount terminal block for 37-pin D-Sub Modules
781503-01
Terminal Block
37-Pin Female D-SUB to 37-Pin Female Screw-Terminal, C Series Terminal Block - The NI-9923 includes one 37-Pin female screw terminal with a 37-pin female D-SUB back-end connection to help you connect a circuit to another circuit.
-
Product
Terminal Board With 100-Pin SCSI-II Connector For General Purpose Servo & Stepper
DIN-825-4P0
Terminal Board
- Supports specific servos & steppers by cable selecting- On-board connector type: 100-pin SCSI-II- Dimensions: 300 mm x 107 mm x 44 mm (W x L x H)
-
Product
TB-4304, PXI 96-Pin Female DIN to 82-Pin Female Screw Terminal Block
783870-01
Terminal Block
The TB-4304 provides an industrial PXI front-mounting Terminal Block for PXIe-4304 and PXIe-4305 PXI Analog Input Module. It features a 42 V maximum voltage measurement range.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
9-Pin Male D-Sub to 5-Pin Female Screw Terminal, Breakout for CAN Terminal Block
780041-01
Terminal Block
9-Pin Male D-Sub to 5-Pin Female Screw Terminal, Breakout for CAN Terminal Block - The CAN Breakout Box works with high-speed, low-speed, and single-wire controller area network (CAN) devices or PC interfaces. It features 14 ports for connecting devices with cables or directly to wiring harnesses. With an onboard power supply, the CAN Breakout Box can place power on the V+ pin required by some CAN transceivers. With a switch on the front panel, you can select 120 Ω, 60 Ω, or no termination on the network. You can use the CAN Breakout Box in desktop applications or mounted on a DIN Rail for test fixtures and cabinets.
-
Product
3U OpenVPX Sensor Interface Unit
SIU32S
Sensor Interface Unit
The SIU32S is a highly configurable Modular Open Systems Approach (MOSA) rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, processing, communications and Ethernet switching. The SIU32S leverages NAI’s Configurable Open Systems Architecture™ (COSA®) 3U boards and smart function modules to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
Product
BNC-2110, 68-Pin SCSI to Female BNC and Spring Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block
777643-01
Terminal Block
68-Pin SCSI to Female BNC and Spring Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2110 can be used with various NI multifunction I/O and analog output devices. The BNC-2110 simplifies the connection of analog signals, some digital signals, and two … user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It includes a DIN Rail and a desktop mount option.
-
Product
CB-50LP Low-Cost, Unshielded I/O Connector Block
777101-01
Terminal Block
50-Pin Male IDA to 50-Pin, Female Screw Terminal, Panel Mount Terminal Block - The CB-50LP provides 50 screw terminals for connection to I/O signals from 50-pin NI data acquisition devices. The CB-50LP includes one 50-pin header for direct connection to 50-pin cables and metal standoffs for use on a desktop or for mounting on a custom panel.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch
40-190B-202
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 or 2-Wire Dual 4×32 Matrix Matrix Topology Without Column Protection Resistors
782385-13
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Motion Control Terminal Board For Mitsubishi J2S-A Servo Amplifiers
DIN-812M0
Terminal Board
- On-board connector type: 100-pin SCSI-II female- Suitable for Mitsubishi J2 super servo- Dimensions: 123 mm x 107 mm x 44 mm (WxLxH)- Available for PCI-8132
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix topology With Column Protection Resistors
782385-10
Terminal Block
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
High-Density Precision SMU (100 PA, 30 V)
PZ2130A
Source Measure Unit
The Keysight PZ2130A is a high-channel density precision source / measure unit (SMU) with 5 channels per module that saves space at a low cost per channel for a wide range of applications requiring numerous precision power supplies. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2130A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2130A suitable for noise sensitive applications such as quantum computing as well.
-
Product
Terminal Block For 34921A And L4421A Multiplexer
34921T
Terminal Block
Offers a built-in thermocouple reference junction that helps minimize errors due to thermal offset
-
Product
BNC-2120, 68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block
777960-01
Terminal Block
68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.
-
Product
PXI Remote Control Interface Cable, 7m
41-924-700
Remote Interface Cable
The 41-924-700 is a 7m cable accessory for the PCIe to PXI Remote Control Interface Kit. The kit provides a seamless connection between a PC’s PCIe slot and a PXI chassis and is suitable for providing an interface to any PXI chassis.
-
Product
Source/Measure Unit for Functional Test, Multiple Ranges, 80 W, Double-wide
N6786A
Source Measure Unit
Only Keysight`s N6780 Series SMUs let you visualize current drain from nA to A in one pass and one picture unlocking insights to deliver exceptional battery life.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
96-Pin Female DIN to 67-Pin Female Screw Terminal, 10 V, PXI Module Mount Terminal Block
781349-01
Terminal Block
NI TB-4353 Isothermal Terminal Block for PXIe-4353
-
Product
TB-2636, Screw Terminal, 4x32, 2-Wire PXI Module Matrix Terminal Block
196762-01
Terminal Block
The TB-2636 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 4×32 matrix. You can directly connect the TB-2636 to the front panel I/O connectors of the PXI-2529. The TB-2636 includes screw terminals that provide access to the rows and columns of the matrix.
-
Product
Source Measure Units (SMUs)
B1511B
Source Measure Unit
The SMUs of B1500A integrate 4-quadrant voltage/current source and measurement capabilities for accurate IV measurement with the range of 0.1 fA - 1 A / 0.5 µV - 200 V. It supports spot, sweep, pulse sampling and QS-CV measurements.
-
Product
PXIe Precision Source/Measure Unit, 1.25 MSa/s, 10 fA, 210 V, 315 mA
M9601A
Source Measure Unit
M9601A PXIe precision SMU is the industry-first precision PXIe SMU enabling faster precise measurement from DC to 20 μs pulse up to 210 V/315 mA with the best-in-class 10 fA resolution and low noise.
-
Product
NI 9924 Front-mount terminal block for 25-pin D-Sub Modules
781922-01
Terminal Block
NI 9924 Front-mount terminal block for 25-pin D-Sub Modules
-
Product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
Fault Insertion Unit
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
Terminal Block
-
The Terminal Block provides standard back-end connector types, such as BNC, D-SUB, VHDCI, and more. Some models offer screw pin terminals for the front-end connectors as well as different mounting options including DIN vertical rail, DIN horizontal rail, wall, panel, or module. You can use terminal blocks for connecting analog or digital signals, generating signals, prototyping, performing custom circuitry, and more.