Standard Transformers
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T1-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
NanoLattice Pitch Standard for Mask Handling Tools (NLSM)
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
Product
Global Standard Model For 4 Point Probe Sheet Resistance Automatic Measurement System
RT-3000/RG-1000F
-
*Fully automatic system for large sizes of flat panel with glass loading robot*Tester self-test function, Measurement position correction function, wide measurement range*Min. 0.1 mm meas. resolution and user programmable test pattern*Host (CIM) communication and 2-D/3-D Mapping software
-
Product
Transformer Winding Resistance Meter
10A
-
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
Product
Standard Accessory Replacement Kit for PP017/PP018
PKIT4-5MM-101
-
Standard Accessory Replacement Kit for PP017/PP018.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25J-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J40
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1A-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4G
-
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
I/Q Signal Generation for Digital Radio Standards
WinIQSIM2
-
R&S®WinIQSIM2™ was especially developed to easily generate digitally modulated signals on a PC. The graphical user interface allows intuitive operation by offering a convenient way to create standard-conforming waveforms for many configurable digital standards and to generate multicarrier signals and multisegment waveforms. With these capabilities, R&S®WinIQSIM2™ covers a wide range of applications.
-
Product
Wall Transformer, Converters & Chargers
-
PeakTech Prüf- und Messtechnik GmbH
An appliance for holding or inserting a charge of power.
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1P1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2G40
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2LB-8
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
FlexVNX+ Test And Development Platform Aligned To SOSA And VITA 90 Standards
39S08VPX98Y2VAN
-
Elma’s all-new FlexVNX+ Test and Development chassis is the next generation portable test platform designed to accelerate development and test of VNX+ plug-in cards (PICs) aligned to The Open Group® SOSA™ Technical Standard and VITA 90.
-
Product
2210A & 2211A Quartz Frequency Standards
-
Precise Time and Frequency, Inc.
The ptf 2210A Quartz Frequency Standard has been designed to provide a highly stable and spectrally pure frequency reference for applications requiring the ultimate in short term frequency performance.The instrument contains a double oven controlled stress compensated (SC cut) quartz crystal oscillator (OCXO) to give the ultimate in performance.Ideal for laboratory or system use, the unit provides good stability performance at lower cost and with improved phase noise.
-
Product
Injection Transformer
J2101A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Intex Beam Gauge & Standard Contacts
-
Developed to measure both internal and external diameters and lengths, the Intex gauge's aluminium extrusion beam gives it a rigid yet lightweight quality, making it ideal for shop-floor environments. The simple release of a locking thumbscrew enables the gauge's measuring direction to be changed quickly and easily.
-
Product
Vertical Space Transformers
ST
-
The Space Transformer (ST) is an integral part of the probe card, utilized between the probe head and the PCB. Nidec SV Probe provides a wide variety of space transformation options including: • WST™ (Wired Space Transformer) • MST™ (Modular Space Transformer) • MLC (Multi-Layer Ceramic) • MLO/Mini-PCB (Multi-Layered Organic) • Multi-Site MLO Reflow of Package Substrate • MLC with MLTF to 50µm PitchOne of the main priorities for Nidec SV Probe is the internal development and manufacture of our own probe card components. We now offer in-house manufactured space transformer technologies with shorter lead time and competitive pricing. Contact your sales representative to learn more about our internally manufactured STs or any of our other ST technologies.
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1C1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I8-4
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Digital Multimeter - Auto Ranging
MM39
-
The MM39 is an auto-ranging multimeter with a large rotary switch for easy selection of the required test, even when wearing gloves. There are two test buttons, one to lock the range and the other to hold the results which are displayed on a 3½ digit LCD screen.
The main test functions are AC voltage and DC voltage and current and resistance. The MM39 measures both AC and DC voltage between 0.1mV to 600V and AC and DC current between 10mA to 10A. There is a diode test and an audible continuity test which sounds at less than 25Ω.
-
Product
Standard Handheld Display
TW-3.0-S
-
The TW-3.0-S Standard Handheld Display is a modern, slimline, multifunctional load monitoring device which is unique to DLM. This innovative design is built with the user in mind. It has a large, high quality LCD screen which is optically bonded removing the need for a back light and improving clarity in bright sunlight. For ease of use each handheld can be given a customisable friendly name made visible on the screen to make instant identification possible. This multi featured high precision unit ensures reliable load readings while also being simple to operate. It can be used in conjunction with any DLM manufactured load cell, just look for the d+ logo on our products.
-
Product
Transformer Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
Your product description goes here.
-
Product
400/5A CHEAP SPLIT CORE CAST RESIN CURRENT TRANSFORMER
LZCK310-10
-
Beijing GFUVE Electronics Co.,Ltd.
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
-
Product
Transformer Test System
-
Transformer testing instrument, can be used as a stand-alone device and has the highest efficiency. Can be used in power transformers, network communication transformers, etc.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1Z1-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Automatic Three Phase Transformer Ratio Meter
-
*For automatic measurement of ratio & phase angle deviation. *Digital presentation of ratio & phase angle deviation. *Ratio range of 0.2 to 199.99 to 1 in three ranges. *Automatic polarity indication. *High accuracy and resolution Accessories: Range Extender 1:10





























