Photovoltaic Reference Cells
See Also: Photovoltaic Cell, Solar Reference Cells
-
Product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
Resistivity Cell
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
Product
AC Reference Modules
Reference Module
NAI offers a variety of AC reference modules that provide a drive capability to 5 VA. The units are transformer-isolated and operate over a frequency range from 47 Hz to 10 kHz. These modules are specifically designed for rugged defense, commercial aerospace, and industrial applications.
-
Product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
Resistivity Cell
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
Product
E-Band Signal Analysis Reference Solution
Reference Module
The E-band signal analysis reference solution provides an effective measurement solution for today’s wideband signals as well as emerging communications standards. With the M1971E waveguide harmonic mixer, which provides a 55 to 90 GHz input; Keysight oscilloscopes, which provide excellent signal integrity; and the powerful 89600 VSA software, you have a high-quality wideband measurement solution. A simple user interface also provides integrated mixer setup, correction and LO optimization, allowing for accurate measurements.
-
Product
Resistivity Cell For N1413 (50 Mm Electrodes)
N1424A
Resistivity Cell
The N1424A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424A to the B2985B/87B.
-
Product
Reference Cells
-
Reference cell is used for measuring and setting the intensity of solar simulators for one sun (or other user desired) intensity condition. They are also used to calibrate the IV Measurement system photo-detector intensity to match the measured ISC to calibrated ISC.
-
Product
Photovoltaic
-
For solar panel installations, problems such as insulation resistance degradation or issues with ground/earth continuity can pose a risk to safety as well as efficient operation. Continuous and predictive maintenance is essential to ensure regulatory compliance as well as the prevention of electrical hazards and fire risks, and enables operators to ensure the optimal performance of PV installations.
-
Product
Solar Reference Cell
-
The Solar Reference Cells consist of a 20 mm x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 mm x 70 mm x 16 mm metal enclosure with a protective quartz window and a temperature sensor. Designed for calibrating the irradiance of solar simulators used for testing solar cells and modules.
-
Product
Reference Cells For PIV-IV Systems
-
NREL calibrated cell used for calibration transfer.The Abet Technologies solar reference cell is a precision instrument for the determination of solar simulator irradiance levels. The sensor is a mono-crystalline silicon solar cell having an area of2x2cm(4cm).The back of the solar cell is attached to the device in such a way that a good heat transfer to the device housing is guaranteed. Below the solar cell a Pt100 RTD temperature sensor is mounted to allow monitoring of device temperature. The device is not shunted allowing the whole IV-curve to be measured. The solar cell is protected by a high quality fused silica window, assuring spectral sensitivity over a 320 -1100 nm range.
-
Product
Solar Photovoltaic
-
Scientific Computing International
Automated metrology system designed for rapid, reliable, and accurate characterization of nearly any unpatterned thin film.
-
Product
Photovoltaics
-
JRT Photovoltaics GmbH & Co. KG
The basis for high efficiency levels is innovative engineering. We led our customers through the transition of crystalline photovoltaics to actual production already back in the year 2000.
-
Product
PV Reference Cells
-
Our silicon-based solar irradiance sensors (Si-Sensors) measure the irradiance intensity on your photovoltaic system with utmost precision.
-
Product
Reference Electrodes
-
PotentioLab reference electrodes provide stable potential control for three-electrode electrochemical testing. Options include Ag/AgCl reference electrodes and laboratory designs for aqueous systems, salt bridge use and compatible custom electrochemical cells.
-
Product
Direct Burial Half Cell Reference Electrode
DB-A
-
Model DB-A Copper-Copper/Sulfate Reference Electrode designed for direct burial for long term monitoring of buried or earth contacting structures.
-
Product
Frequency Reference
E8-X
-
The Quartzlock E8-X is a breakthrough in exceptionally low cost, miniature, traceable, calibration-free, off-air frequency & time standards. These references maintain the high frequency & time accuracy required for demanding applications.
-
Product
Frequency Reference
-
Quartzlock time and frequency standards offer a complete range of cost effective and low noise in both atomic controlled (rubidium oscillator) and GPS controlled (off-air) time and frequency reference, calibrators and standards. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
Product
Reference data
-
The performance data of the SiTek PSDs conform to the highest standards. The device specification data are measured in a well-defined environment but are also proven to be perfectly adequate in widely diverse environments, including those of an extremely demanding nature.
-
Product
Micropower Voltage References
-
Analog Devices offers a broad line precision micropower voltage references with extremely low quiescent currents (series references) or minimum shunt currents (shunt voltage references). All of our precision voltage references offer excellent initial accuracy and low temperature drift over time and temperature. Our Reference Plus products combine precision voltage references with comparators or amplifiers.
-
Product
Voltammetry Cell
SVC-3
-
By using this cell, researchers can run experiments free from gasificationed steam. Also, researchers can get rid of influence of oxygen in the cell by bubbling nitrogen gas. This cell can be utilized with CS-3A Cell Stand. This feature is well suited for measurements of ultraweak current.
-
Product
Voltammetry Cell
SVC-2
-
SVC-2 Voltammetry cell can be used for 4 modes voltammetry cell setup. Each voltammetry cell has its specific feature. However, SVC-2 can be sed in 4 modes. Also can apply as an oxygen-free voltammetry cell.
-
Product
Photovoltaic System Bypass Diode Tester
FT4310
-
Hioki is pleased to announce the launch of the Bypass Diode Tester FT4310 for Photovoltaic Systems. The FT4310, which is designed to test bypass diodes in strings of crystalline photovoltaic cells, can be used to detect open and short-circuit faults in bypass diodes by string either in daylight or at night. The instrument is the first portable device capable of detecting bypass diode open faults in operating panels (without requiring the panels to be shielded from sunlight).
-
Product
Reference Temperature Sensors
-
AMETEK Sensors, Test & Calibration
Our reference sensors can be used as your daily working-reference sensors in laboratory or field calibration applications. A large selection of types are available, including; straight, 90 degree angle, 4 mm or 1/4”. The superior design and specifications combined with a long history of reliability and low drift have made the STS probes the working-standard in many EN/IEC 17025 accredited laboratories worldwide. The DLC sensors are a part of our patented Dynamic Load Compensation system.
-
Product
Reference Antennas
Type NRD
-
Reference antennas are precision dipole antennas that offer a fixed 2.15 dB of gain over an isotropic antenna along the major lobe axis at specified frequencies (2.15 dBi). They are intended to be used for antenna field pattern and gain measurements, or general RF sensing in the laboratory.
-
Product
Load Cells
-
For use in harsh environments, our Models T66 (bending beam),T85 and T85-T(shear beams)are manufactured fromstainless steel, fully welded and hermetically sealed to provide total environmental protection (IP68 and IP69K). The T85-Tmodel has a blind loading hole, ideal for use in platform scales.
-
Product
Reference Frequency Generator
MFCh
-
*Frequency reproduction accuracy ± 2 x 10 -9 *Output frequency 1 Hz - 10 MHz *Output pulse signal 1 kHz The MFC is designed to generate high-frequency pulse signals with a frequency of 1 kHz and a frequency in the range from 1 Hz to 10 MHz along two output lines. The MFC is designed to operate in measuring systems based on the VXIbus trunk. In the MFC, a rubidium frequency standard is used as a reference frequency source. Time to reach the mode when the power source of the rubidium standard is turned on, no more than 10 min
-
Product
Series Voltage References
-
Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.
-
Product
Reference Magnets And Zero Chambers
-
Reference Magnets with different magnetic field strenghts and dimensions. Available field strenghts ranging from 10mT to 1,4T. We deliver the Reference Magnets with a Factory Certificate. Zero Chambers are required to set zero of gaussmeters. We deliver two different types of Zero Chambers.
-
Product
Low Concentration Photo-Voltaic (LCPV) & High Concentration Photo-Voltaic (HCPV) Cell Testing
-
Concentrated PV Cell testingPhoto-biological studies of plants, animals, and cell culturesSemiconductor testingPhoto-toxicity researchMaterial degradation researchAccelerated UV and solar exposure testing of color fastness and material stability for paints, textiles and plasticsAtmospheric photochemical pollution research
-
Product
nVision Reference Recorder
-
AMETEK Sensors, Test & Calibration
Accurate enough to replace a deadweight testerRugged enough to sit in 3 feet of waterPortable enough to complete calibrations anywhere